Mega Lite drama z fresnel 200 User Manual

Summary of drama z fresnel 200

  • Page 1

    User manual table of contents safety information………………………………………………………………3 specifications…………………………………………………………………...4 main power connection………………………………………………………..5 dmx-512 connection…………………………………………………………..5 dmx profile ...................................................................................

  • Page 3

    Check that the unit has not been damaged during transport protection against fire 1. Maintain a minimum of 1 foot distance from any type of flame. 3. Replace fuse only with the specified type and rating. 4. Do not install the unit to close to a heat source. 5. Make sure cable are properly secured aw...

  • Page 4: Technical Information

    Technical information 4 part numbers fixture 7025-cw drama z fresnel 200 cool white 7025-ww drama z fresnel 200 warm white 7025-bd removable barn door (included) 70250gh removable gel holder (accessory) mechanical specifications fixture packaged for shipping size: 18.5”l x 10.75”w x 14”h weight: 19 ...

  • Page 5: Main Power Connection

    5 main power connection caution! 1. Do not connect fixture to a dimmer system. 2. This unit has auto switching power supply. It will respond to 110v or 220v automatically 3. This unit must be earthed. (electronically grounded) 4. Replace fuse only with the specified type and rating. The occupation o...

  • Page 6: Dmx Profile

    6 dmx profile drama z fresnel mode 2 ch dmx chanel function description value 1 dimmer led intensity 0-255 2 zoom linear zoom 0-255 drama z fresnel mode 3 ch dmx chanel function descriptions value 1 dimmer led intensity 0-255 2 zoom linear zoom 0-255 no function 0 2 strobe strobe (slow to fast) 1-12...

  • Page 7: Main Control

    7 main control the control board on the fixture base is your interface to access and control all the functions on the unit. It’s digital display gives you a code view of the options and functions. The following will explain each func- tion and its options. Address 001 this function allows you to set...

  • Page 8: Cleaning And Maintenance

    Cleaning and maintenance installation maintenance: the operator has to make sure that the unit is operating safely and has the installa- tions and electronics checked by an expert every 2 years. The following points have to be considered during the inspection: 1) all screws used for installing the d...

  • Page 9: Warranty Information

    Mega-lite 5718 kenwick st san antonio, tx 78238 ph 210-684-2600 fax 210-855-6279 www.Mega-lite.Com / info@mega-lite.Com warranty information warranty conditions -unless otherwise stated in writing, your product is covered by a one year parts and labor limited warranty. -leds are not guaranteed to ma...