Megger MIT510/2 User Manual

Manual is about: 5kV Digital Insulation Tester

Summary of MIT510/2

  • Page 1

    M mit510/2 5kv digital insulation tester user manual.

  • Page 2

    2 note the instrument must only be used by suitably trained and competent persons. Users of this equipment and/or their employers are reminded that national health and safety legislation requires them to carry out valid risk assessments of all electrical work so as to identify potential sources of e...

  • Page 3

    Symbols used on the instrument are: f caution: risk of electric shock g caution: refer to accompanying notes t equipment protected throughout by double insulation (class ii) c equipment complies with current eu directives. Terms used in this manual the word must is used to indicate that the instruct...

  • Page 4

    If the power lead supplied is not suitable for your type of mains outlet, do not use an adaptor. Always use a power lead fitted with the correct plug. Nb: a plug severed from the power lead is a hazard if plugged into a live socket. Severed plugs must be destroyed immediately. The instrument is fitt...

  • Page 5

    8. To stop the test press test button. 9. Timer will stop. 10. Analogue display shows insulation resistance. 11. Digital display shows resistance or current selected by pressing Ω /i button. 12. Load capacitance will be calculated and displayed after the end of the test. 13. Time-constant will be di...

  • Page 6

    Power on/off button the instrument will only turn on if this button is pressed, held and then released when the display responds. The instrument will not turn on if the button is released before the display responds, or if the button is held down for too long. This is a safety feature to prevent the...

  • Page 7

    The guard terminal is at the same potential as the negative terminal. Since the leakage resistance is effectively in parallel with the resistance to be measured, the use of the guard causes the current flowing through surface leakage to be diverted from the measuring circuit. The instrument therefor...

  • Page 8

    8 instrument will not perform a test. The high voltage warning indicators flash, and the beeper sounds, to warn of the hazard until the external voltage becomes less than 50 v. When testing, the voltage displayed is the voltage present at the test terminals of the instrument. If the test voltage is ...

  • Page 9

    Capacitance display at the end of a test the capacitance of the circuit under test is calculated and displayed. After a test the display shows the last measurement made until the v s, vt, or test buttons are pressed. Time constant: at the end of a test the time constant of the circuit under test is ...

  • Page 10

    10 voltage input range 85-265 v rms, 50/60hz, 60 va battery life typical capacity is 6 hours continuous testing at 5 kv with a 100 m Ω load test voltages 250 v, 500 v, 1000 v, 2500 v, 5000 v accuracy (23°c, 5 kv) ±5% @ 1 t Ω ±20% @ 10 t Ω guard 2% error guarding 500 k Ω leakage with 100 m Ω load dis...

  • Page 11

    11 humidity 90% rh non-condensing at 40°c dimensions 305 x 194 x 360 (mm) (12 x 7.6 x 14.2 inches) weight 6.75 kg (15lb) approx voltage output accuracy (0°c to 30°c) +4%, -0% ±10 v of nominal test voltage at 1 g Ω load current measurement range 0.01 na to 5 ma current measurement accuracy (23°c) ±5%...

  • Page 12

    12 accessories order code included accessories 3 m lead set, medium size insulated clips 6220-820 user guide on cd-rom 2000-213 optional accessories hv test lead sets 3 x 3 m with un-insulated small clips 8101-181 3 x 8 m with un-insulated small clips 8101-182 3 x 15 m with un-insulated small clips ...

  • Page 13

    13 repair and warranty the instrument contains static sensitive devices, and care must be taken in handling the printed circuit board. If an instrument’s protection has been impaired it should not be used, but sent for repair by suitably trained and qualified personnel. The protection is likely to b...

  • Page 14

    M megger limited archcliffe road, dover kent ct17 9en england t +44 (0)1 304 502101 f +44 (0)1 304 207342 e uksales@megger.Com megger 4271 bronze way, dallas, texas 75237-1019 usa t +1 800 723 2861 (usa only) t +1 214 333 3201 f +1 214 331 7399 e ussales@megger.Com megger z.A. Du buisson de la could...