MEI CashFlow 560 Application Manual - Electrical Interfaces

Manual is about: REFERENCE SERIES CHANGEGIVER

Summary of CashFlow 560

  • Page 1

    23174 g 4 142922044 cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® ca shflow ® cashflow ® cashflow ® cashflow ® cashflow ® cash flow ® cashflow ® cashflow ® cashflow ® cashflow ® cashfl ow ® cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® cashflow ® ca...

  • Page 2

    Ii ©, mei ., 1996. Cashflow 560 changegiver applications design guide published by : mei internet: http://www.Meigroup.Com for information on translations in your country, please write to the technical communications manager at the above address. Cashflow 560 changegiver applications design guide ©,...

  • Page 3: Table of Contents

    ©, mei ., 1996. Iii cashflow 560 changegiver applications design guide table of contents safety ....................................................................................... 1 overview ................................................................................. 2 product operation ......

  • Page 4: Product Interfaces

    Iv ©, mei ., 1996. Cashflow 560 changegiver applications design guide coin count re-calibration................................... 19 home sensors................................................... 20 product interfaces ...................................................... 21 electrical interfaces....

  • Page 5

    ©, mei ., 1996. V cashflow 560 changegiver applications design guide float down mode.............................................. 39 resetting tube counts ..................................... 39 price teach ...................................................... 39 homing the dispensers ..............

  • Page 6: Environmental Performance

    Vi ©, mei ., 1996. Cashflow 560 changegiver applications design guide environmental performance ................................. 66 temperature range ................................................... 66 humidity........................................................................... 66 vibrati...

  • Page 7: Safety

    ©, mei ., 1996. 1 cashflow 560 changegiver applications design guide safety international & national standards conformance when installed and operated according to the instructions for the particular unit, cashflow 560 products are designed to meet the applicable safety and electro mechanical confor...

  • Page 8: Overview

    2 ©, mei ., 1996. Cashflow 560 changegiver applications design guide overview the cashflow 560 range of changegivers have been designed to address a wide range of market needs and are compatible with the majority of modern vending machines. They are plug compatible replacements for the previous ms16...

  • Page 9

    ©, mei ., 1996. 3 cashflow 560 changegiver applications design guide the basic functionality of all changegivers is to: • accept payment • signal the payment available to the machine (credit output) • monitor the product request inputs (sense inputs) • return un-used change • monitor the machine inh...

  • Page 10

    4 ©, mei ., 1996. Cashflow 560 changegiver applications design guide with the use of the m ei route alpha 250 terminal you can also re-configure certain operational aspects of the changegiver. This includes inhibiting coins, changing from single to multi vend etc.. The cashflow ® 560 electro-mechani...

  • Page 11: Product Operation

    ©, mei ., 1996. 5 cashflow 560 changegiver applications design guide product operation general electro-mechanical product when a coin is entered through the electro-mechanical changegiver there are several conditions that are electronically checked. After coins have been accepted and a product selec...

  • Page 12

    6 ©, mei ., 1996. Cashflow 560 changegiver applications design guide if the vend is allowed the cost will be deducted from the credit prior to authorising the vmc to start the vend. Should the vend fail, this credit will be re-instated. Acceptor module there are some functions of the acceptor module...

  • Page 13

    ©, mei ., 1996. 7 cashflow 560 changegiver applications design guide spaced from the deck on three bosses which locate the lid squarely to the deck. The design of the lid arm hinge area allows the lid to open to 180 degrees relative to the deck. The opening is restricted to just over 100 degrees by ...

  • Page 14

    8 ©, mei ., 1996. Cashflow 560 changegiver applications design guide transformer assembly the transformer assembly is housed behind the keypad cover. To gain access to the transformer there is a screw located under the top flap of the keypad cover. Once this screw has been removed the keypad cover w...

  • Page 15: Coin Sizes For Each Tube

    ©, mei ., 1996. 9 cashflow 560 changegiver applications design guide tube combinations coin sizes for each tube tube position a position b position c position d 0 ✘ ✔ ✘ ✘ 1 ✘ ✔ ✘ ✘ 2 ✘ ✔ ✔ ✔ 2.5 ✘ ✔ ✔ ✔ 3 ✘ ✔ ✔ ✔ 3.5 ✔ ✔ ✔ ✔ 4 ✔ ✔ ✔ ✔ 4.5 ✔ ✔ ✔ ✔ 5 ✔ ✔ ✔ ✘ 5.5 ✔ ✔ ✔ ✘ 6 ✔ ✘ ✔ ✘ 6.5 ✔ ✘ ✔ ✘ 7 ✔ ✘ ✔ ✘...

  • Page 16

    10 ©, mei ., 1996. Cashflow 560 changegiver applications design guide although there are different sizes of tubes and designators available, not every tube can be fitted into every position in the cassette. There are prisms located at the top of each tube which, when combined with the optos on the s...

  • Page 17

    ©, mei ., 1996. 11 cashflow 560 changegiver applications design guide address 237 = exact change equation, part 2 - sets a second selection of change tubes. Address 383 can also be used, with bdv product only, to give an additional early warning setting, (in conjunction with addresses 271-274), and ...

  • Page 18

    12 ©, mei ., 1996. Cashflow 560 changegiver applications design guide using exact change inhibit when the machine is in exact change mode, selected coins can be inhibited, other than with mdb product. Setting the exact change inhibit option will stop a specified coin or coins being accepted when the...

  • Page 19

    ©, mei ., 1996. 13 cashflow 560 changegiver applications design guide coin acceptance, routing & return the changegiver has a standard coin entry and exit chuting. Coin return via a reject lever is also standard. The coin acceptance, and the routing used on coin acceptance, are dependant on: • the s...

  • Page 20

    14 ©, mei ., 1996. Cashflow 560 changegiver applications design guide global coin inhibit in addition to the individual coin inhibits described above, a global coin inhibit can be imposed. This will inhibit all coin acceptance regardless of any other conditions. A global inhibit is imposed when: • m...

  • Page 21

    ©, mei ., 1996. 15 cashflow 560 changegiver applications design guide change payback in general the changegiver will attempt to return any coin credit to the consumer, in the best possible coin mix. However, this simple statement requires clarification. Use of tubes • the changegiver will only attem...

  • Page 22

    16 ©, mei ., 1996. Cashflow 560 changegiver applications design guide tube sensor usage this section describes the operation of the tube sensors in more detail. The sensor operation significantly affects the users perception of how the changegiver appears to operate. Each tube has associated with it...

  • Page 23

    ©, mei ., 1996. 17 cashflow 560 changegiver applications design guide coin cassette removal detection if the coin storage cassette is removed, all the tube full sensors on the tubes will read covered. Should the changegiver detect this all tubes full condition, it will flag a cassette removed error ...

  • Page 24

    18 ©, mei ., 1996. Cashflow 560 changegiver applications design guide attempted with the coin cassette back in place. Note that if all tubes really have overfilled to cover the sensors then a cassette removed error will be indicated, but will clear once the tube level drops. Full sensor error detect...

  • Page 25

    ©, mei ., 1996. 19 cashflow 560 changegiver applications design guide coin count re-calibration low level recalibration is intelligent in its handling of tube storage cassette removal and replacement. The main assumption made is that the tube storage cassette is not removed during a change return op...

  • Page 26

    20 ©, mei ., 1996. Cashflow 560 changegiver applications design guide the following table gives a brief summary of the low sensor operation. Home sensors the function of the home sensors is to signal that the dispenser arms are in the correct parked position before an attempt to dispense coins from ...

  • Page 27: Product Interfaces

    ©, mei ., 1996. 21 cashflow 560 changegiver applications design guide product interfaces the external interfaces to the changegiver product can be divided into two groups and are explained in the following pages. • electrical interfaces: includes looms to interface host machine with 4-price, executi...

  • Page 28: Electrical Interfaces

    22 ©, mei ., 1996. Cashflow 560 changegiver applications design guide electrical interfaces the diagram below illustrates the external electrical interfaces and options for the cashflow 560. Note: the machine and serial communications loom are connected together within the changegiver for the cashfl...

  • Page 29

    ©, mei ., 1996. 23 cashflow 560 changegiver applications design guide the mains electro-mechanical interface circuit diagram for cashflow 560 4 price is shown below. Host interface for cashflow 560 4 price line neutral exa ct change price line common price line 1 price line 2 price line 3 price line...

  • Page 30: Master

    24 ©, mei ., 1996. Cashflow 560 changegiver applications design guide protocol a equivalent circuit as applicable to executive, bdv and mdb versions. The cashflow 560 executive, bdv and mdb products do not require any related electro-mechanical interfaces. However, the executive does require a 24v a...

  • Page 31: Electro Mechanical Interface

    ©, mei ., 1996. 25 cashflow 560 changegiver applications design guide electro mechanical interface all electro-mechanical interface connections between the changegiver and the host vending machine are electrically isolated. Outputs are isolated via the relays (i.E. Price line outputs) and the inputs...

  • Page 32: Machine Interface

    26 ©, mei ., 1996. Cashflow 560 changegiver applications design guide machine interface the normal idle state of the electro-mechanical / 4 price machine interface with no credit is as follows: • blocker input active (connected to line) • ea input (if present) - inactive • sense input lines inactive...

  • Page 33

    ©, mei ., 1996. 27 cashflow 560 changegiver applications design guide single / multi vend unused credit (change) is returned to the customer either automatically or on demand by pressing the reject lever. If the changegiver is set to single vend mode any unused credit is returned automatically immed...

  • Page 34

    28 ©, mei ., 1996. Cashflow 560 changegiver applications design guide output is removed (excluding blocker hold reset mode). The price line output will be energised again if the sense input is still active and sufficient funds exist to pay for the product requested. Vend finished while the vend is i...

  • Page 35

    ©, mei ., 1996. 29 cashflow 560 changegiver applications design guide delayed blocker reset blocker reset is the most commonly used reset condition in this reset mode the price line output remains active for either 30 ms (most commonly used) or 200 +/- 10 ms after the vend start signal is detected (...

  • Page 36

    30 ©, mei ., 1996. Cashflow 560 changegiver applications design guide blocker hold reset the changegiver waits for the vend start signal (blocker) to return to its normal active state to indicate the vend cycle was successful. When blocker returns the reset condition is met the price line output is ...

  • Page 37

    ©, mei ., 1996. 31 cashflow 560 changegiver applications design guide escrow accept in this mode the escrow accept (ea) input is used in conjunction with the blocker input to indicate a successful completion of a vend cycle. Normally, blocker removal signals the vend has started. The end of the vend...

  • Page 38

    32 ©, mei ., 1996. Cashflow 560 changegiver applications design guide price sense / blocker / escrow accept / vend start/ inhibit inputs rated the maximum source impedance (from vending machine) to allow the changegiver to correctly sense an input is dependant on the voltage profile of the unit as f...

  • Page 39: External Credit Display

    ©, mei ., 1996. 33 cashflow 560 changegiver applications design guide external credit display for electro-mechanical interface applications the external display, if fitted, can provide the following information: • current credit in real money (consumer) • vend price in real money, used in price disp...

  • Page 40

    34 ©, mei ., 1996. Cashflow 560 changegiver applications design guide displaying vend price if price display is enabled, and you make a selection whose value is less than the current system credit, then the display will show the price of the vend, in real money, while the selection is active. Leadin...

  • Page 41: Terminal Connector

    ©, mei ., 1996. 35 cashflow 560 changegiver applications design guide voltage ranges the following profiled mains voltage ranges are supported across the defined 4 price and executive product range: • 20.4 - 26.4vac covering voltages 24v +10%, -15%) • 87 - 121vac (covering voltages 100v -13%, +21%) ...

  • Page 42: Man Machine Interfaces

    36 ©, mei ., 1996. Cashflow 560 changegiver applications design guide man machine interfaces keypad all changegivers have a keypad mounted on the front face. Two leds are also mounted in this area to indicate the operational state of the changegiver. The keypad will enable the following functions to...

  • Page 43

    ©, mei ., 1996. 37 cashflow 560 changegiver applications design guide led usage the top (yellow) led is used to indicate whether the keypad is in normal or shifted mode. If the led is off, the keypad mode is in normal mode. When the mode key is pressed, the yellow led will start to flash at 2 hz ( ±...

  • Page 44

    38 ©, mei ., 1996. Cashflow 560 changegiver applications design guide time being less than this) until the tube counts reach their programmed safe count, or any key is pressed. If 2, or more, letter keys are pressed at the same time, then the changegiver will pay coins from the selected tubes in the...

  • Page 45

    ©, mei ., 1996. 39 cashflow 560 changegiver applications design guide float down mode when you wish to float down the tubes, simply press the mode key to get to the shifted functions, then press the a key to enter float mode, followed by the c key. At this point the changegiver will start to dispens...

  • Page 46

    40 ©, mei ., 1996. Cashflow 560 changegiver applications design guide the sequence of inserting coins then making a selection can be repeated for all selections for which you wish to modify the price. Note that the main principle of price teach is that selections will have their price set to the cur...

  • Page 47

    ©, mei ., 1996. 41 cashflow 560 changegiver applications design guide internal diagnostics & error handling the indication of an error being present either in the host or in the changegiver is given by the red led. This section details various errors, and the action taken by the changegiver. • host ...

  • Page 48

    42 ©, mei ., 1996. Cashflow 560 changegiver applications design guide blocker return the end of vend condition on electro-mechanical hosts depends on the reset mode selected. In blocker hold mode, the end of vend is signalled by the return of the blocker signal. If this does not occur, the following...

  • Page 49

    ©, mei ., 1996. 43 cashflow 560 changegiver applications design guide no response • indicate host error on led • disable all coin acceptance in normal mode • manual dispense is still allowed • allow return of credit • terminal comms is still allowed • changegiver will continually check if failure re...

  • Page 50

    44 ©, mei ., 1996. Cashflow 560 changegiver applications design guide home sensor failure • indicate changegiver error on led • disable use of affected tube • set required bit(s) in disabled tubes error register • signal exact change • manual dispense attempts from the tube are still allowed • error...

  • Page 51

    ©, mei ., 1996. 45 cashflow 560 changegiver applications design guide • the configuration version number must be corrected. The error will then be cleared on changegiver re- initialisation. This can be done by; • clearing the error flag, • updating the eeprom version number, • re-initialising. Eepro...

  • Page 52

    46 ©, mei ., 1996. Cashflow 560 changegiver applications design guide audit fem problems audit not initialised if a fem is present but has not be initialised, the following applies: • set code 5 in error register • indicate changegiver error on led • no coin in / out events will be audited • vending...

  • Page 53

    ©, mei ., 1996. 47 cashflow 560 changegiver applications design guide • set codes 2 / 3 in error register • will not allow the changegiver to enter float or teach modes. • coin acceptance inhibited • manual dispense is not allowed • terminal comms is still allowed (if access is permitted) • changegi...

  • Page 54: Via

    48 ©, mei ., 1996. Cashflow 560 changegiver applications design guide via mei route alpha 250 terminal with a mei route alpha 250 terminal you can re-configure any of the functions available for a particular product. The terminal is connected to the acceptor via a six way connector which plugs into ...

  • Page 55

    ©, mei ., 1996. 49 cashflow 560 changegiver applications design guide key functions reset key: used to reset all modes and to initialise any settings that you have changed. If the reset key is pressed while an address is being updated then the address may not be updated. The reset key must be presse...

  • Page 56

    50 ©, mei ., 1996. Cashflow 560 changegiver applications design guide auto repeating keys if either the up or down keys are kept pressed they automatically repeat. The repeat speed of the key increases the longer the key is held down. Double click hotkeying if a key is doubled clicked (pressed twice...

  • Page 57

    ©, mei ., 1996. 51 cashflow 560 changegiver applications design guide the basic operation to alter the information held in an address is: 1 connect the terminal to the cashflow product. 2 wait for the terminal to power up correctly. 3 select the address by using the up and down keys. 4 examine the d...

  • Page 58

    52 ©, mei ., 1996. Cashflow 560 changegiver applications design guide visual audit visual audit can be obtained, from the electro-mechanical and executive products only, when an audit function expansion module (fem) is installed as an accessory on to the control pcb. Data can be viewed with the use ...

  • Page 59

    ©, mei ., 1996. 53 cashflow 560 changegiver applications design guide the following process should be followed to use the route alpha 250 terminal for retrieval of data: • firstly select the required address using the up and down keys. • press enter to display the contents of the address. If the val...

  • Page 60

    54 ©, mei. , 1996. Cashflow 560 changegiver applications design guide route alpha 250 address applications the symbols below appear on the following pages together with most of the following route alpha 250 address numbers. They can be used as an aid to indicate which variety of product that each ad...

  • Page 61

    ©, mei ., 1996. 55 cashflow 560 changegiver applications design guide addresses and values the table below shows you the address of each item that can be re- configured and their possible values. Address parameter range meaning ✙ 21 - 32 coin types 1 - 12 0-2 0 = coin 1 = value token 2 = vend token ...

  • Page 62

    56 ©, mei ., 1996. Cashflow 560 changegiver applications design guide ▲ 231 coin inhibit, coins 9 -12 0 -15 0 = no coins inhibited 1 = inhibit coin 9 2 = inhibit coin 10 4 = inhibit coin 11 8 = inhibit coin 12 ✙ 232 exact change inhibit group inhibit coins 1 - 4 0 -15 1 = coin 1 2 = coin 2 4 = coin ...

  • Page 63

    ©, mei ., 1996. 57 cashflow 560 changegiver applications design guide ✙ 243 clear overpay inhibit options 0 -1 0 = cleardown allowed 1 = cleardown inhibited ✙ 244 keypad inhibit options 0 -1 0 = keypad enabled 1 = keypad inhibited ✙ 245 price teach inhibit options 0 -1 0 = price teach allowed 1 = pr...

  • Page 64

    58 ©, mei ., 1996. Cashflow 560 changegiver applications design guide ▲ 340 full sensor errors read only 0 - 255 tubes 1/2/4/8 = a/b/c/d 128 = post gate strobe errors ▲ 341 tube dis-abled data 0 - 31 tubes a/b/c/d read only ▲ 342 eeprom errors (i) data read only 0 - 15 1 = errors in page 0 2 = error...

  • Page 65

    ©, mei ., 1996. 59 cashflow 560 changegiver applications design guide ✖ 362 audit module - printout type options 0 - 2 0 = basic 1 = basic + interim vend report 2 = basic + interim vend + free vend report ✖ 363 audit module - printout product limit 0 - 25 limit details on printout to first few speci...

  • Page 66

    60 ©, mei ., 1996. Cashflow 560 changegiver applications design guide ✸ 388 card revaluation allowed 0 - 1 0 = revaluation not allowed, 1 = revaluation allowed ✸ 389 audit unit fitted 0 - 1 0 = not fitted, 1 = audit unit fitted ✸ 390 vmc unit fitted 0 - 1 0 = not fitted, 1 = vmc fitted ✸ 391 cpc uni...

  • Page 67

    ©, mei ., 1996. 61 cashflow 560 changegiver applications design guide ✖ 900 cash in tubes (ls) 0-65535 visual audit ✖ 901 cash in tubes (ms) 0-65535 visual audit ✖ 902 value of cash sales interim (ls) 0-65535 visual audit ✖ 903 value of cash sales interim (ms) 0-65535 visual audit ✖ 904 number of ca...

  • Page 68

    62 ©, mei ., 1996. Cashflow 560 changegiver applications design guide ✖ 917 overpay (ms) 0-65535 visual audit ✖ 918 exact change vend value (ls) 0-65535 visual audit ✖ 919 exact change vend value (ms) 0-65535 visual audit ✖ 920 value of cash manually filled (ls) 0-65535 visual audit ✖ 921 value of c...

  • Page 69

    ©, mei ., 1996. 63 cashflow 560 changegiver applications design guide ✖ 934 value of free sales total (ls) 0-65535 visual audit ✖ 935 value of free sales total (ms) 0-65535 visual audit ✖ 936 number of free sales total (ls) 0-65535 visual audit ✖ 937 number of free sales total (ms) 0-65535 visual au...

  • Page 70

    64 ©, mei ., 1996. Cashflow 560 changegiver applications design guide diagnosing terminal problems sympton cause solution terminal displays an error message at power up communications error press reset terminal displays an error message when changing from address to data mode or vice versa communica...

  • Page 71

    ©, mei ., 1996. 65 cashflow 560 changegiver applications design guide testing the terminal it is possible to test all the features of the terminal itself by putting the unit into a special test mode. To enter the test mode hold the enter key pressed when powering the unit up. The display will initia...

  • Page 72: Environmental Performance

    66 ©, mei ., 1996. Cashflow 560 changegiver applications design guide environmental performance products are available to meet the following environmental specification. Temperature range working ambient - 15 to 60 ° c max rate of change 15 ° c/hr non condensing storage -40 to + 65 ° c solar radiati...

  • Page 73: Transportation

    ©, mei ., 1996. 67 cashflow 560 changegiver applications design guide transportation units in the packed state will not sustain any physical damage under these conditions: shock half sine, 30g shock, 18ms dur. Refer to bs 2011: part 2.1 ea: 1977 bump 1000 bumps 6ms duration at 25g. Refer to bs 2011:...

  • Page 74: Voltage

    68 ©, mei ., 1996. Cashflow 560 changegiver applications design guide voltage supply the unit will operate to specification on the following supply voltages: 46 - 64 hz ac rms. • 20.4 - 26.4 v rms • 87 - 121 v rms • 95 - 132 v rms • 187 - 242 v rms • 212 - 264 v rms • 207 - 244 v rms* single transfo...

  • Page 75: Safety Classifications

    ©, mei ., 1996. 69 cashflow 560 changegiver applications design guide safety classifications classification the product will comply with: • ul 756 “coin and currency changers and actuators” • iec 335, 3rd edition “safety of household and similar electrical appliances” partitions all of the following...

  • Page 76: Safety Insulation

    70 ©, mei ., 1996. Cashflow 560 changegiver applications design guide safety insulation safety insulation is provided between: a) all operator points of contact without tool access and hazardous voltages b) selv circuits and hazardous voltages safety insulation (as defined above) is provided as foll...

  • Page 77: Mechanical Parts

    ©, mei ., 1996. 71 cashflow 560 changegiver applications design guide electro-mechanical and mains input ratings • input: (line and neutral) fused neutral only 1.6a thermal fault rating 3.5a • exact change fused neutral only 1.6a thermal load rating 0.5a fault rating 3.5a • price line common • price...

  • Page 78: Compatibility

    72 ©, mei ., 1996. Cashflow 560 changegiver applications design guide compatibility the cashflow 560 product range is compatible with the majority of modern vending machines. It is a plug compatible replacement for the previous ms1500, ms1600, me1600 and me1900 series of changegivers. The options cu...

  • Page 79

    ©, mei ., 1996. 73 cashflow 560 changegiver applications design guide t7 fa, no credit relay (gen. Purpose loom) adaptor looms 3, 4, 5 and 6 are used in conjunction with this loom t8 fd,b74,f 01 ✓ 4 t9 fc,b60,f 08,f33 ✓ 4 t11 fe,f12 ✓ 4 t12 fg,f44 ✓ 4 t13 -- ✓ 4 machine loom 165972002 ff, f26 adapto...

  • Page 80: Bill Validator Interface

    74 ©, mei ., 1996. Cashflow 560 changegiver applications design guide bill validator interface the electro-mechanical and executive products can be used in conjunction with a bill validator. To do so the following elements must be present before commencing an installation: • cashflow ® changegiver p...

  • Page 81: Interface Cable Options

    ©, mei ., 1996. 75 cashflow 560 changegiver applications design guide the successful connection of the changegiver and the bill validator has two phases, that of installing the robust terminal cable into the changegiver, and the connection of that cable to the bill validator. To install the robust t...

  • Page 82

    76 ©, mei ., 1996. Cashflow 560 changegiver applications design guide to connect the bill validator to the changegiver: a) ensure that the required interface cable is available, confirming this with the table on the previous page. Each cable should have its part number on a label attached to it. B) ...

  • Page 83: Bill Validator Interface

    ©, mei ., 1996. 77 cashflow 560 changegiver applications design guide ? ✍ 600 0 - 15 601 - 603 0 - 65,535 611 0 - 65,535 612 0 - 7 613 0 - 7 mei , eskdale road, winnersh triangle, wokingham, berkshire. Rg41 5aq, great britain bill validator interface # $ 1 $ 5 $ 10 1 2 4 + + ? ? ? $ 1 $ 5 $ 10 $ 1 $...

  • Page 84: Ei Offices

    78 ©, mei ., 1996. Cashflow 560 changegiver applications design guide m ei offices www.Meigroup.Com.

  • Page 85: Index

    ©, mei ., 1996. 79 cashflow 560 changegiver applications design guide index a accept gate module 6, 7 acceptor initialising error 47 acceptor module 2, 6, 7, 16, 75 appendix 84 audit fem problems 46 automatic tube float 38 b best change calculation 15 bill validator cable 74 bill validator interface...

  • Page 86

    80 ©, mei ., 1996. Cashflow 560 changegiver applications design guide credit 15 credit relay drive 25 d dangerous environments 1 default inhibits 13 designators 10 discriminator 6 dispalying float value 34 dispalying vend price 34 dispense arms 20 dispenser module 2, 8 dispenser motor failure / jam ...

  • Page 87

    ©, mei ., 1996. 81 cashflow 560 changegiver applications design guide full sensor failure 43 g global coin inhibit 14 h hinge spring 7 home sensors 20 home sensors failure 44 homing dispenser 40 host inhibited 41 host machine problems 41 humidity 66 i inhibit inputs 32 interface compatibility 72 int...

  • Page 88

    82 ©, mei ., 1996. Cashflow 560 changegiver applications design guide power on indicator 34 price line common 25 price line outputs 25 price teach mode 13, 39, 40 product interfaces 21 product operation 5 product overview 2, 3 protocol a errors 42, 43 r reject lever 13 resetting tube counts 38, 39 r...

  • Page 89

    ©, mei ., 1996. 83 cashflow 560 changegiver applications design guide vibration 66 voltage range 35 voltage transients 68 voltage (supply) 68.

  • Page 90: Appendix

    84 ©, mei ., 1996. Cashflow 560 changegiver applications design guide appendix interface drawing mechanical interface drawing number 148324001, consisting of 3 separate sheets, shows details of the following: • reject mechanism & coin routes • mounting details • space envelope.

  • Page 91

    ©, mei ., 1996. 85 cashflow 560 changegiver applications design guide.

  • Page 92

    86 ©, mei ., 1996. Cashflow 560 changegiver applications design guide.

  • Page 93

    ©, mei ., 1996. 87 cashflow 560 changegiver applications design guide.

  • Page 94

    ™ representative:.