Modine Manufacturing PD/BD Installation Instructions Manual

Other manuals for PD/BD: Installation Instructions Manual

Summary of PD/BD

  • Page 1

    For units being converted from natural gas to propane gas concurrently follow carefully the propane conversion instructions, found in bulletin 75-511, using the proper high altitude main burner orifices called out in this literature (75-535) instead of the orifices in propane conversion kit. Selecti...

  • Page 2

    2 75-535.11 table 2.1 - natural gas - 2001 to 4500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”, “h”,“i”, & ,“o” ➀ ➁ table 2.2 - natural gas - 4501 to 5500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”, “h”,“i”, & ,“o” ➀ ➁ model model size type 30 50 75 100 125 130 150 170...

  • Page 3

    3 75-535.11 table 3.1 - natural gas - 5501 to 6500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”, “h”,“i”, & ,“o” ➀ ➁ table 3.2 - natural gas - 6501 to 7500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”, “h”,“i”, & ,“o” ➀ ➁ ➀ all conversion kits have the same base part numb...

  • Page 4

    4 75-535.11 table 4.1 - propane gas - 2001 to 4500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”,“h”,“i”, & ,“o” ➀ ➁ table 4.2 - propane gas - 4501 to 5500 ft. Elevations - pd/bd, pdp/bdp, psh/bsh, model series “d”,“h”,“i”, & ,“o” ➀ ➁ model model size type 30 50 75 100 125 130 150 170 1...

  • Page 5

    5 75-535.11 model model size type 30 50 75 100 125 130 150 170 175 200 225 250 280 300 340 350 400 pd/bd 30 50 75 100 125 - 150 - 175 200 - 250 - 300 - 350 400 kit suffix -31 -106 -78 -59 -46 - -77 - -109 -79 - -48 - -40 - -42 -86 drill size 54 49 43 49 45 - 43 - 46 44 - 41 - 43 - 43 44 orifices in ...

  • Page 6: Warning

    6 75-535.11 conversion of any unit is the responsibility of, and the risk of the person making the conversion. Installation step 1 turn off all electricity and gas to unit. Pd/bd, pdp/bdp, pv/bv models lower bottom pan to expose burner and manifold (see figure 6.1). “d”, “h”, “i”, & “o” models (not ...

  • Page 7

    7 75-535.11 figure 7.1 - pdp high efficiency ii unit heater figure 7.3 - high altitude conversion label figure 7.2 - lifting flame step 5 on the high altitude conversion label (see figure 7.3) write the drill size, as stamped on orifice, with a permanent marker. Be sure to check correct orifice size...

  • Page 8

    75-535.11 table 8.1 - high altitude kit cross reference (3h # to item code) cross reference figure 8.2 - typical serial plate unit heater for industrial / commercial use aerotherme pour usage industriel / commercial model number numero de modele 0 to 2000 ft. 0 et 610 m. (in canada) 2000 to 4500 ft....