Modine Manufacturing POR oil-fired unit Installation Instructions Manual

Manual is about: Oil Fired Unit Heaters

Summary of POR oil-fired unit

  • Page 1

    4-112.3 september, 2008 oil fired unit heaters.

  • Page 2

    2 maximum performance, comfort, and efficiency modine model por oil-fired unit heaters offer an efficient and reliable means of heating, particularly in regions where supplies of other fuels, such as natural gas, may be unavailable, undependable, or interruptible. The units are direct driven propell...

  • Page 3

    3 superior heat exchanger life expectancy long life is due in part to the roll-formed design of the heat exchanger. Stresses caused by thermal expansion and contraction typically concentrate in areas of sharp angular bends or adjacent to welds, all of which are minimized with roll-forming to distrib...

  • Page 4

    Table 4.1 - dimensions (inches) approx. Model a b c d e f g h j k l m y shipping wt. (lbs) por100 27-1/2 35-1/4 28-1/8 25 23-7/8 13-3/4 8-5/8 23-7/8 8 12 38-1/8 16 8 324 por145 27-1/2 35-1/4 28-1/8 25 23-7/8 13-3/4 8-5/8 23-7/8 9-1/2 12 38-1/8 16 8 333 por185 28-5/8 40-1/4 32-3/4 26-1/8 23-7/8 14-3/...

  • Page 5: 4-521.4

    F fiirre e p po ott r re ep plla ac ce em me en ntt 1. Remove louvers by pushing each to the left against the coil spring and pulling out opposite end. 2. Remove access door by removing six (6) brass bolts at top and bottom of access door. Loosen the brass retaining nuts at the right and left edges ...

  • Page 6

    4-530 5h080577a november, 2008 installation instructions cas-2b field control airboot™ outside combustion air kit for model por with beckett model af burner this manual is the property of the owner. Please be sure to leave it with the owner when you leave the job. Modine manufacturing company has a ...

  • Page 7

    Installation – cas-2b field control airboot™ outside combustion air kit 2 4 -530 assembly/installation the recommended procedure for assembly and installation is described as follows: step 1 - airboot™ installation a. Remove the fuel pump, air shutter, and air band from the burner housing. B. Remove...

  • Page 8

    Installation – cas-2b field control airboot™ outside combustion air kit 4-530 3 horizontal level across pivot points vertical diagonal figure 6 sk9555 step 3. Intake air hood location (horizontal ducting) mount intake air hood 12 inches above finish grade. If mounting on the side of a building prone...

  • Page 9

    Commercial products group • modine manufacturing company • 1500 dekoven avenue • racine, wisconsin, usa 53403-2552 phone: 1.800.828.4328 (heat) • www.Modine.Com © modine manufacturing company 2008 4 -530 11/08 litho in usa.