1.4 ELECTRICAL SPECIFICATIONS:
Model
92 PCV
94 PCV
94 CFV
Rated voltage
400V – 3N~ 50 Hz
Total power kW
6,8
13,6
19,6
Power cable
H05RN-F
H05RN-F
H05RN-F
Cross section
5 x 2,5 mm
2
5 x 4 mm
2
5 x 6 mm
2
Dimensions mm
Width
Depth
Height
450
900
250
900
900
250
900
900
850
The data plate contains all necessary information with installation and it is located on the
posterior part near the terminal block of the models.
2. PRELIMINARY INSTALLATION INSTRUCTIONS
The appliance must be positioned in a well-aired room, if possible under a hood to remove
cooking steam thoroughly.
Before starting the appliance, remove all protective film; thoroughly clean the surfaces with a
soft cloth, lukewarm water and detergent, so as to remove all anti-rust products applied
during the manufacturing stage, then dry with a clean cloth.
If the appliance is installed near walls, partition walls, kitchen furniture, decorative panelling,
etc., these should be constructed with fireproof materials or a space of at least 100 mm
should be left free.
Make sure that fire prevention rules are strictly respected.
According to the model our appliances can be floor standing or they can be installed on
cantilever support.
The main switch and the socket must be near the appliance and easily accessible.
Using the levelling feet lay the appliance flat, adjust the height and ensure its stability.
2.1 Regulations, technical rules and general specifications
Comply with the following rules during assembly:
1) accident prevention rules;
2) rules in force in the country where the appliance is installed;
3) carefully read this booklet as it contains important instructions about installation safety,
use and maintenance;
4) keep this booklet for further reference.