Moeller MFD-CP4 Manual

Manual is about: Power supply/Communication module

Summary of MFD-CP4

  • Page 1

    Moeller gmbh industrieautomation hein-moeller-straße 7–11 d-53115 bonn e-mail: info@moeller.Net internet: www.Moeller.Net © 2002 by moeller gmbh subject to alteration awb2528-1548gb doku/doku/eb 10/04 printed in the federal republic of germany (xx/xx) article no.: 262671 easy800 a a think future. Sw...

  • Page 2

    All brand and product names are trademarks or registered trademarks of the owner concerned. 1 st published 2004, edition date 10/04 © moeller gmbh, 53105 bonn authors: dieter bauerfeind, jörg mattke editor: thomas kracht translator: terence osborn all rights reserved, including those of the translat...

  • Page 3

    I before commencing the installation • disconnect the power supply of the device. • ensure that devices cannot be accidentally restarted. • verify isolation from the supply. • earth and short circuit. • cover or enclose neighbouring units that are live. • follow the engineering instructions (awa) of...

  • Page 4

    Ii • measures should be taken to ensure the proper restart of programs interrupted after a voltage dip or failure. This should not cause dangerous operating states even for a short time. If necessary, emergency- stop devices should be implemented. • wherever faults in the automation system may cause...

  • Page 5

    1 10/04 awb2528-1548gb about this manual 3 explanation of terms 3 other manuals 4 writing conventions 4 1 about the display/operator system 5 target readership 5 proper use 5 overview 6 – display/operator system at a glance 8 type references 9 operating principles 10 main menu 11 2 installation 13 m...

  • Page 6

    2 10/04 awb2528-1548gb 3 commissioning 29 switching on 29 initial commissioning 30 4 use 31 point-to-point connection 31 net operation 32 connection faulty 33 graphic mode on the remotely operated device 33 5 settings 35 station selection 35 setting the menu language 36 changing the lighting 37 chan...

  • Page 7

    3 10/04 awb2528-1548gb about this manual this manual describes the installation, commissioning and possible settings on the display/operator system. Explanation of terms the display/operator system described here consists of the mfd-cp4 power supply/communication module, the mfd-80.. Display/operato...

  • Page 8

    About this manual 4 10/04 awb2528-1548gb other manuals the mfd-cp4 can be connected to easy500, easy700, easy800 or mfd-cp8... Basic units. These easy basic units are described in separate manuals (awbs): • easy500/700 (awb2528-1508gb) • easy800 (awb2528-1423gb) • mfd-titan, multi-function display (...

  • Page 9

    5 10/04 awb2528-1548gb 1 about the display/operator system target readership the mfd-cp4 must only be installed and connected up by trained electricians or persons familiar with the installation of electrical equipment. A specialist knowledge of electrical engineering is needed for commissioning. Wh...

  • Page 10

    About the display/operator system 6 10/04 awb2528-1548gb overview the display/operator system can be connected with easy500, easy700, easy800 or mfd-cp8... Basic units to implement the following tasks: • display on the mfd-cp4 of the status or text display of the connected basic unit. • remote opera...

  • Page 11

    Proper use 7 10/04 awb2528-1548gb figure 1: system overview ( legend a page 6) del ok al t esc a b c d e c d.

  • Page 12

    About the display/operator system 8 10/04 awb2528-1548gb display/operator system at a glance the display/operator system consists of the power supply unit/communication module and the display/operator unit display and operator unit figure 2: display/operator unit a del button b graphic display c alt...

  • Page 13

    Type references 9 10/04 awb2528-1548gb power supply/communication module figure 3: power supply/communication module a power supply b serial interface for point-to-point connection type references a b mfd - cp4 - xxx supplied connection cable for interface (optional) 500 = mfd-cp4-500-cab5 800 = mfd...

  • Page 14

    About the display/operator system 10 10/04 awb2528-1548gb operating principles the buttons of the display/operator unit have the following functions: go to next menu level select menu item activate, modify, save your entry return to last menu level cancel your entry since the last ok Í Ú ú í change ...

  • Page 15

    Type references 11 10/04 awb2528-1548gb main menu status display connection establishment in progress... * * i .2..5....... Nt1 p- mo 08:00 q..34.... Run text display status or text display of the connected device main menu current selection flashes in the mfd-cp4 menu cursor Í Ú cursor Í Ú cursor Í...

  • Page 16

    12 10/04 awb2528-1548gb setting values special function selection mode: black rectangle flashing or entry mode: number flashing press ok to toggle between selection and entry modes. Press ok or esc to move from entry mode to selection mode of the main menu Í Ú change value the result of the value ch...

  • Page 17

    13 10/04 awb2528-1548gb 2 installation the mfd-cp4 must only be installed and connected up by trained electricians or a person familiar with the installation of electrical equipment. The mfd-cp4 is installed in the following order: • mounting, • connecting the serial interface, • connecting the powe...

  • Page 18

    Installation 14 10/04 awb2528-1548gb figure 4: minimum clearance to mfd-cp4 fitting the protective membrane for special applications such as in the food industry, the operator unit must be protected against the ingress of dust, liquids etc. In this case fit the protective membrane over the display/o...

  • Page 19

    Mounting 15 10/04 awb2528-1548gb figure 5: fitting the protective membrane a protective membrane b display and operator unit a b caution! Ensure that the membrane fits snugly in the groove of the display/operator unit. Otherwise a proper seal cannot be guaranteed and particles may enter underneath t...

  • Page 20

    Installation 16 10/04 awb2528-1548gb figure 6: correct position of the protective membrane mounting the protective cover the protective cover is provided for using the device in aggressive environments. This protects the display and the operator unit against mechanical damage or destruction. Protect...

  • Page 21

    Mounting 17 10/04 awb2528-1548gb x first remove the front frame before mounting. Figure 7: removing the front frame the protective cover can be mounted in two different positions. X choose the position that is most suitable for the application at hand and your requirements. Figure 8: position of the...

  • Page 22

    Installation 18 10/04 awb2528-1548gb x mount the protective cover as shown in the figure. Figure 9: mounting the protective cover sealing the protective cover figure 10: sealing the protective cover the grip handle of the protective cover is provided with holes that can be used in any mounting posit...

  • Page 23

    Mounting 19 10/04 awb2528-1548gb mounting the display/operator unit (front mounting) x drill and punch out two 22.5 mm diameter holes in the front plate. The diameter is the same as is normally required for control circuit devices. Figure 11: drill holes for the mfd h the protective membrane or the ...

  • Page 24

    Installation 20 10/04 awb2528-1548gb x fit the display/operator unit in the punched fixing holes. Figure 12: mounting the display/operator unit x tighten the display/operator unit with the m22-ms combination box spanner (a figure 13). The tightening torque must be between 1.2 and 2 nm h ensure that ...

  • Page 25

    Mounting 21 10/04 awb2528-1548gb figure 13: screw fastening the display/operator unit figure 14: rear of the mounted display/operator unit removing the display/operator unit (front mounting) x unscrew the fixing element and remove the display/ operator unit. 2 x.

  • Page 26

    Installation 22 10/04 awb2528-1548gb mounting the power supply/communication module figure 15: mounting the power supply/communication module.

  • Page 27

    Terminals 23 10/04 awb2528-1548gb removing the power supply/communication module use a screwdriver with a 100 x 3.5 mm slot width. X insert the screwdriver into the lug of the fixing shaft catch. X lever out the slide catch. X pull out the power supply/cpu module from the fixing shafts. Figure 16: r...

  • Page 28

    Installation 24 10/04 awb2528-1548gb connecting the power supply dc power supply mfd-cp4 figure 17: power supply on the mfd cable protection provide cable protection (f1) of at least 1 a (slow) on the mfd-cp4. H the required connection data for the mfd-cp4 is provided in the section “technical data”...

  • Page 29

    Terminals 25 10/04 awb2528-1548gb connecting the connection cable the mfd-cp4 is provided with a serial interface. This is used for point-to-point communication between the mfd-cp4 and an easy500, easy700, easy800 or mfd-cp8.. If there is no pc connected to these devices. Selecting a suitable connec...

  • Page 30

    Installation 26 10/04 awb2528-1548gb connecting the connection cable x remove the interface cover carefully. X use a screwdriver to press down the recess next to the terminal and connect the wires of the connection cable to the terminals in the order stated . Proceed accordingly in the reverse order...

  • Page 31

    Terminals 27 10/04 awb2528-1548gb x fit the connection cable plug into the easy basic unit. Figure 19: fitting the connection plug a to the easy basic unit left:easy800/mfd, right: easy500/700

  • Page 32

    28 10/04 awb2528-1548gb.

  • Page 33

    29 10/04 awb2528-1548gb 3 commissioning switching on before switching on check that the power supply and the connection cable are properly connected: – terminal +24 v: voltage +24 v – terminal 0 v: voltage 0 v if you have already integrated devices into a system, secure any parts of the system conne...

  • Page 34

    Commissioning 30 10/04 awb2528-1548gb initial commissioning when you switch on the display/operator system for the first time, you will be asked to select the menu language. X select the required menu language and confirm the setting by pressing the ok button. X press esc to exit language selection....

  • Page 35

    31 10/04 awb2528-1548gb 4 use you can use the display/operating system for a point-to- point connection or in the easy-net network. Easy-net operation is only possible in combination with easy800/mfd devices. Point-to-point connection figure 20: possible point-to-point connection via the serial inte...

  • Page 36

    Use 32 10/04 awb2528-1548gb net operation mfd-cp4 mfd-cp4 easy 8.. Easy 8.. Mfd-cp8.. Mfd-cp8.. Easy 8.. Easy 8.. Pc h communication via easy-soft is not possible if a network station (easy800 or mfd-cp8) is connected with a pc and an mfd-cp4 is accessing this device. This also applies to program up...

  • Page 37

    Graphic mode on the remotely operated device 33 10/04 awb2528-1548gb connection faulty if the connection is faulty or interrupted, the mfd-cp4 will display the message “connection establishment in progress...” continuously. This message may, however, also be due to an incorrect com setting (a sectio...

  • Page 38

    34 10/04 awb2528-1548gb.

  • Page 39

    35 10/04 awb2528-1548gb 5 settings the following settings to the connected basic unit can be made via the display/operator system. Station selection pressing the “*” activates the main menu of the display/ operator system. X press the “*” button. The main menu will appear. X select the com menu item...

  • Page 40

    Settings 36 10/04 awb2528-1548gb x exit the com menu with esc. You can leave the main menu at any time by pressing the “*” button. When the main menu is left, the mfd-cp4 tries to establish connection to the selected device. The status and text display of the remotely operated device is displayed as...

  • Page 41

    Setting the menu language 37 10/04 awb2528-1548gb changing the lighting if the main menu of the display/operator system is not active, press the “*” button to enter the menu. X use the Í and Ú buttons to select the lighting menu item. The cursor moves to the percentage value of the lighting. X press...

  • Page 42

    Settings 38 10/04 awb2528-1548gb changing the contrast if the main menu of the display/operator system is not active, press the “*” button to enter the menu. X use the Í and Ú buttons to select the contrast menu item. The cursor moves to the percentage value of the contrast. X confirm with ok. Use t...

  • Page 43

    39 10/04 awb2528-1548gb 6 appendix dimensions mfd-80.. Display/operator unit mfd-80-xm protective membrane mfd-80-xs protective cover 32 17 20 13.7 86.5 30 g 0.2 62 86.5 28.25 28.25 mfd-cp... 22.3 +0.4 30 88.5 22.5 88.5 86.5 25 95.

  • Page 44

    Appendix 40 10/04 awb2528-1548gb mfd-cp4 power supply/communication module technical data general ambient conditions 75 58 36.2 30 22.5 22.5 climatic conditions (damp heat constant to iec 60068-2-78; cyclical to iec 600618-2-30) (cold to iec 60068-2-1, heat to iec 60068-2-2) ambient temperature inst...

  • Page 45

    Technical data 41 10/04 awb2528-1548gb ambient mechanical conditions pollution degree power supply/cpu module 2 display/operator unit 3 degree of protection (en 50178, iec 60529, vbg4) power supply/cpu module ip20 display/operator unit ip65 display/operator unit with protective cover ip65 display/op...

  • Page 46

    Appendix 42 10/04 awb2528-1548gb mfd-80.. Display/operator unit / dielectric strength overvoltage category ii measurement of the air clearance and creepage distance en 50178, ul 508, csa c22.2, no 142 dielectric strength en 50178 tools and cable cross-sections power supply terminal solid and flexibl...

  • Page 47

    Technical data 43 10/04 awb2528-1548gb mounting 2 22.5 mm (0.886 in) holes display fastened with two fixing rings maximum tightening torque of the fixing rings [nm] 1.2 to 2 power supply by means of mfd-cp4 power supply/communication module lcd display type graphic/monochrome visible area w x h mm 6...

  • Page 48

    Appendix 44 10/04 awb2528-1548gb mfd-xm-80 protective membrane mfd-80-xs protective cover dimensions w x h x d mm 88 x 88 x 25 inches 3.46 x 3.46 x 0.98 weight g 25 lb 0.055 mounting is fitted over the display/keypad (with titan front ring) dimensions w x h x d mm 86.5 x 94 x 25 inches 3.41 x 3.41 x...

  • Page 49

    Technical data 45 10/04 awb2528-1548gb mfd-cp4 power supply/communication module dimensions w x h x d mm 75 x 58 x 36.2 inches 2.95 x 2.28 x 1.43 weight g 164 lb 0.362 mounting fitted on the fixing shaft of the display power supply rated voltage rated value v dc, (%) 24, (+20, –15) permissible range...

  • Page 50

    46 10/04 awb2528-1548gb.

  • Page 51

    10/04 awb2528-1548gb 47 index b baud rate ............................................................11 c cable protection ..................................................24 commissioning ....................................................29 communication via easy-soft .............................

  • Page 52

    Index 10/04 awb2528-1548gb 48 mounting display/operator unit ....................................19 power supply/communication module ..........22 protective cover ...........................................16 protective membrane ...................................14 mounting the display/operator un...

  • Page 53

    Index 49 10/04 awb2528-1548gb u use ........................................................................5.

  • Page 54

    10/04 awb2528-1548gb 50