NA OMEGA + User Manual - page 15
Omega Dimmer series User manual version 1.0 09.2011
15
limits from 50 to 100%.
"Patch" - DMX channel setup for each output channel individually. Use buttons and encoder to
asigne each output a specific DMX address:
Example:
"Output 7"
"DMX in 401"
"Lamp Dynamic" - a lamp on / off time settings. For lamp life increasing. Settings are set equal
for all output channels:
- for DMX Control from DMX input,
- for test mode,
- and from external analogue encoders.
"Lamp ON time "
"= 30 msec " - default
"Lamp OFF time "
"= 0 msec " - default
"Curve " – Lamp control curve selection. The first 5 options corresponding to different lamp
management curves, but the last ("Non-dim") - for Relay mode:
"Square "
"Linear " - default
"Lin-Law"
"NACurve"
"S-Curve"
"Non-dim" - for Relay mode
"Engineer menu"
- engineering settings. PIN2 required (****).
Engineering menu, default settings
"Total channels" - Output channel count. Actual count of connected outputs. The limit from 1 to
48.
"NonDimm setting" - Relay mode setup individually for each output channel using the graphical
editor.
"Period register" - Phase control period. Default = 580th
"Fan control" - Fan control. Are set the following parameters:
"Fan slow Temp" – Minimum speed temperature,
"= 45 C " - default
"Fan fast Temp" – Maximum speed temperature,
"= 70 C " -default
"Lamp off Temp" – Regulators shut-off temperature,
"= 95 C " -default
"Minimum speed" - Minimum speed (20 - 100 %)
"= 33 % " -default
"Fan off delay" – Fan off time delay (0-30 min).