Nacecare NR17 Owner's Manual

Summary of NR17

  • Page 1

    Nr17/nr20 owners manual attention! Do not use the machine without having read the instructions nacecare solutions 1205 britannia rd e. Mississauga, on, canada l4w 1c7 tel: 1 800 387 3210 fax: 1 800 709 2896 visit us on the web: www.Nacecare.Com.

  • Page 2

    Assembly instructions assembling the handle and tank nr17/nr20 put the handle in vertical position, place its support on the four holes and insert all the screws. Insert the four lock nuts (m8) in the slots placed under the frame. Tighten the bolts one at the time, keeping the four lock nuts in the ...

  • Page 3

    Assembly instructions insert the tank on lower bracket and lower the top bracket until it is resting on the tank. Tighten the bolt on the top bracket with the hand know. Connect the handle cable with the motor cable and the solution tube in the suitable hole placed on the left side of the frame..

  • Page 4

    2 summary summary .........................................................................................................................2 delivery of the machine ..............................................................................................3 technical descripti0n ....................

  • Page 5

    3 the delivery of the machine when the machine is received, ensure to check that all components are in the box and that the machine has not been damaged in transport. This machine has been designed for use on hard floors. Any use of the machine, other than the recommended use is dangerous and could ...

  • Page 6

    4 technical data unit nr17 nr20 machine width inches 17” 20" machine length inches 23.5” 25” machine height (motor) inches 14” 14” machine height (handle) inches 47” 47” brush rpm rpm 154 154 voltage v 115 115 motor power w 1100 1100 frequency hz 60 60 weight lbs 88 88 power cable length ft 50 50 Ø ...

  • Page 7

    5 machine preparation preparing the machine for first use upon delivery of the machine, please ensure that the owner’s manual is read thoroughly. If there is multiple users for the machine, ensure that they have a full understanding of how to use the machine in a safe manner. Water tank assembly put...

  • Page 8

    6 machine preparation the machine must be perfectly horizontal, and vertical on the pad driver/brush. Move the handle from left to right until the chuck drops in to the pad driver/brush. With the safety switch pressed down (b). Activate the motor using the two levers (c) until the chuck and the pad ...

  • Page 9

    7 general safety rules any use of the machine other than the specified uses different from the instructions written here or recommended by nacecare solutions is prohibited and could cause bodily harm. Do not remove or replace the specification plates on the machine for any reason. Before operating t...

  • Page 10

    8 work preparation:manoeuvering the machine by pulling the lever (a) lower the handle until the arms of the user are lightly bent. Using your thumb, push down on the safety lever (b) and then engage the motor with the two levers (c). The safety lever (a) must be pressed down every time before the st...

  • Page 11

    9 on completion of the work disassembly of brush/pad driver during storage, the machine must never rest on the brush or on the pad. The machine weight could permanently damage them. To remove the brush, tilt the machine backwards, with your thumb push down on the safety switch and then pull on the m...

  • Page 12

    10 trouble shooting guide insufficient water on the brush check that the solution valve on the bottom of the tank has no debris in it. Also check the solution hose for debris as well. The machine does not clean efficiently check that the brush/pad is not worn. The brush should be changed when the br...