Nantlife Smart Body User manual

Manual is about: Simple Operation High Measuring Accuracy

Summary of Smart Body

  • Page 1

    English smart body scale simple operation high measuring accuracy user manual.

  • Page 2

    1 e n g l i s h n a n t c a r e l l c , 2 9 2 9 n 4 4 t h s t r e e t p h o e n i x , a r i z o n a , 8 5 0 1 8 - 7 2 3 9 - u s a 1 - 8 5 5 - n a n t c a r e - e m a i l : s u p p o r t @ n a n t c a r e . C o m w w w. N a n t c a r e . C o m c o p y r i g h t © r e v i s i o n 0 9 2 0 1 2 smart bod...

  • Page 3

    English english table of contents 1 table of contents 1.1 introduction p 4 1.2 intended use p 4 1.3 safety information p 4 1.3.1 operating the device p 4 1.3.1.1 warnings p 4 1.3.1.2 cautions p 6 1.4 before taking a measurement p 6 2 operating instructions p 7 2.1 know your nantlife body scale p 7 2...

  • Page 4

    4 1.1 introduction thank you for purchasing the nantlife smart body scale. Weight and bmi four load cells measure weight. Bmi is calculated and displayed based on weight. Body composition the scale measures body mass using bioimpedance analysis. Ito electrodes form a pattern on the top of the scale,...

  • Page 5

    English 5 in addition, please note: • to produce precise readings, the device should be placed on a hard and leveled surface. • do not under any circumstances use the device in the bath or the shower. If, however, liquid gets into the device, you must remove the batteries immediately and refrain fro...

  • Page 6

    6 1.3.1.2 cautions • excessive user movement may cause inaccurate readings • all nantlife devices are designed to be compliant with rules and regulations in locations they are sold and are labeled as required. • any changes or modifications to nantlife equipment, not expressly approved by nantlife v...

  • Page 7

    English 7 2 operating instructions 2.1 know your nantlife body scale removable top cover air jack - air plug button lcd display note: the battery compartment is located at the bottom of the body scale caution: substitution of a component different from that supplied might result in measurement error...

  • Page 8

    8 2.3 display symbols symbols operation measure/solution sys (mm/hg) displays systolic value upper value dia (mm/hg) displays diastolic value lower value pulse (1/min) displays pulse pulse rate per minute batteries indicator, empty replace all the batteries mobile wireless data transmission see page...

  • Page 9

    English 9 2.5 batteries replacement when the low battery indicator appears on the display screen, turn off the monitor and remove all the batteries. Replace with 4 new “aa” 1.5v alkaline batteries. Warning: if battery fluid gets in your eyes, rinse with plenty of clean water and contact a physician ...

  • Page 10

    10 2.6 applying the arm cuff caution: read all the information in the instruction manual and any other documents in the box before operating the unit. 1. Open the top cover of the nantlife blood pressure monitor 2. Gently, take the cuff out of the compartment 3. Make sure the air plug is securely in...

  • Page 11

    English 11 3. The cuff starts to inflate automatically. As the cuff inflates, the monitor determines your ideal inflation level. The monitor detects your blood pressure and pulse rate during inflation. The cuff deflates automatically. 4. After a successful measurement, the display will show like the...

  • Page 12

    12 3 care and maintenance 3.1 cleaning if required, wipe the plastic casing with a damp cotton cloth only. Do not use abrasive or volatile cleaners. Important note: the nantlife blood pressure meter cuff cannot be washed or dry-cleaned. Contact us at www.Nantlife.Com for part replacement. 3.2 mainte...

  • Page 13

    English 13 4.2 troubleshooting tips description of the problem solution during the measurement, pressing the button once does not stop the measurement immediately and the cuff does not immedi- ately deflate open the cuff, remove the batteries and do not use the device. Contact the service department...

  • Page 14

    14 5 fcc statement potential for radio/television interference (for u.S.A. Only) this equipment has been tested and complies with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harm- ful interference w...

  • Page 15

    English 15 7 warranty 1. The blood pressure monitor and the arm cuff are warranted to be free from defects in material and workmanship appear- ing within one year from the date of purchase when the moni- tor is used in accordance with the instructions provided with the monitor. Proof of purchase mus...

  • Page 16

    16 8 specifications model bp 4.0 measuring range systole (sys) 70 to 260 mmhg diastole (dia) 30 to 180 mmhg pulse (pulse) 40 to 199 (1/min) operating temperature + 10°c to + 40°c + 50°f to + 104°f operating humidity 15 to 90% rh storage temperature -20°c to 60°c -4°f to + 140°f storage humidity 15 t...

  • Page 17

    English 17 power supply 4 alkaline 1.5v aaa batteries battery life approximately 300 uses starting with new alkaline batteries when inflated to 170mmhg at 73°f (23°c) with standard adult cuff unit dimensions 185mm x 138mm x 100mm 7.3” x 5.4” x 4” weight 980g (34.5oz) not including batteries note: th...

  • Page 18: Wireless Monitoring

    Add more nantlife devices to your wireless monitoring visit us at www.Nantlife.Com.