1 © napco 2005 patented oi309 10/05 r using your napco freedom f-tpg garage touchpad home security system f-tpg_oi309.06_user_anch... Page 1 friday, october 28, 2005 15:16 composite.
2 congratulations on your purchase of a new freedom garage door security sys- tem. This revolutionary new concept in residential security makes using your system easier than ever before possible, because the system uses its computerized control panel to continually monitor the status of your garage ...
3 t ab l e o f c o n t e n t s table of contents introduction ..............................................................................2 testing the system ..................................................................2 garage touchpad indicators ...............................................
4 ready armed stay fire tbl • g ar ag e t o u c h p ad i n d i c at o r s the green ready light shows the status of the zones in your system: on indicates that all zones are secure and the system is ready to be armed. Flashing indicates that at least one zone is open. To determine the open zone, cou...
5 g ar ag e t o u c h p ad c o n t r o l s stay button- press to arm system in the stay mode. Perimeter devices such as windows and doors will be protected, while interior protective devices such as motion sensors will be de-activated, allowing free movement throughout the premises. Away button- pre...
6 ar m i n g w h e n l e av i n g 1 check the garage touchpad indicators. The green ready light should be on-steady, indicating that the system is ready to arm. • if the green ready light is blinking, this indicates that a zone is faulted. The ready light is blinking out the zone number of the open ...
7 b y p as s i n g f au l t e d z o n e s if you are trying to arm with a faulted zone or zones, the green ready light will be blinking out the number of the faulted zones. If you cannot repair the zone(s), they may be temporarily removed from the system, or bypassed, using the fol- lowing procedure...
8 ar m i n g w h e n s t ay i n g h o m e arming in the stay mode allows you to remain home with the perimeter protection active and the interior protection off, so that you may move freely about the premises. 1 check the garage touchpad indicators. The green ready light should be on-steady, indicat...
9 ar m i n g an d l e av i n g w i t h o t h e r s s t ay i n g 1 check the garage touchpad indicators. The green ready light should be on-steady, indicating that the system is ready to arm. • if the green ready light is blinking, this indicates that a zone is faulted. The ready light is blinking ou...
10 e x i t i n g w i t h t h e s y s t e m al r e ad y ar m e d 1 press the stay button on the touchpad. The armed indicator will light and stay will begin to flash, indicating that you have up to 3 minutes to exit through the garage and close the door. 2 open the garage door from the inside. System...
11 e x i t i n g w i t h t h e s y s t e m al r e ad y ar m e d 1 press the away button on the touchpad. The armed indicator will begin to flash, indicating that you have up to 3 minutes to exit through the garage and close the door. 2 open the garage door from the inside. System will disarm. 3 exit...
12 e m e r g e n c y b u t t o n s the emergency buttons, if programmed, are always active, whether the system is armed or disarmed. The emergency button must be held down for 3 seconds to activate the emergency alarm and transmit the signals to central station. Police emergency hold down the police...
13 d i s ar m i n g t h e s y s t e m disarming when returning home: when returning home, opening your garage door (by pressing a1 or a2 on your keyfob) from the outside will automatically disarm the system. The red armed light will go out and the green ready light will turn on. If an alarm has occu...
14 if an alarm occurs while you are at home: the garage touchpad siren will sound and the red armed light will flash. Proceed with caution! If you suspect that an intruder may still be in the premises, leave immediately and call authorities from a neighbor's telephone. To silence the alarm, insert y...
15 if a fire is detected, the siren will sound a distinct pulsating tone and the fire indicator on the ga- rage touchpad will be flashing. If a fire alarm does occur: * note: this feature may not apply to your system. Consult your installer to determine if your system includes fire protection. 1 if ...
16 f i r e p r o t e c t i o n preparing a fire escape plan even with the most advanced fire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your building. Show two exits - a front or back door and a window from each room. (make sure the window wo...
17 your freedom alarm system is constantly monitoring its own components, as well as all critical services, such as ac power and the telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble occurs, the garage touchpad will caution y...
18 system trouble error codes tbl flashes / touchpad beeps ready flashes trouble condition action 6 none lost key mode this is a reminder that the system has been put into the lost key mode ([stay] & [away] pressed simultaneously). While in this mode, the system can only be disarmed with your f-ifob...
19 the space below is for recording the descriptions of the zones in your system. • if the system has a faulted zone, count the number of ready light flashes and refer to the list below to see which zone is open and secure it (close the door or window, etc.). • if an alarm has occurred, count the nu...
20 the f-ifob is a uniquely coded digital key which performs the following functions when inserted into the f-ifob slot on the ga- rage touchpad: • disarm an armed system • silence an active alarm • reset a fire alarm the master f-ifob supplied with your system will perform all of these functions, p...
21 lost opener mode in the event that your garage door remote control (or key that operates your garage door opener) is lost or stolen, the system may still be used by arming in the lost garage door opener mode. In lost garage door opener mode, the system may be armed as usual, how- ever opening the...
22 federal communications commission (fcc) part 68 statement this equipment complies with part 68 of the fcc rules. On the front cover of this equipment is a label that contains, among other information, the fcc registration number and ringer equivalence number (ren) for this equipment. If requested...
23 warning! The limitations of this alarm system while this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variet...
24 warning! The limitations of this alarm system (continued) • even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect them- selves from the situation. In the case of a monitored alarm system, authorities may not respond appropriately. • thi...
25 napco limited warranty napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, at its option, repair or replace any product failing to ope...
26 written, are either merged herein or are expressly cancelled. Napco neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall napco be liable for an amount ...
27 the following statement is required by the fcc radio and television interference this equipment has been tested and found to comply with the limits for a class-b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interf...
28 333 bayview avenue amityville, new york 11701 for sales and repairs, (800) 645-9445 for technical service, (800) 645-9440 publicly traded on nasdaq symbol: nssc r © napco 2005 f-tpg_oi309.06_user_anch... Page 28 friday, october 28, 2005 15:16 composite.