NAPCO FREEDOM F-64TPBR Operating Manual

Manual is about: Bedroom Touchpad Home Security System

Summary of FREEDOM F-64TPBR

  • Page 1

    1 r operating guide for your napco freedom f-64tpbr bedroom touchpad home security system © napco 2006 patented oi319a 9/06 freedom f-64tpbr touchpad f-64tpbr_oi319a.03_user_... Page 1 friday, september 15, 2006 10:39 composite.

  • Page 2

    2 the napco freedom f-64tpbr bedroom touchpad is a “ smart ” interactive menu-driven touchpad with an integral motion sensor, inte- gral siren, and integral speaker designed for your napco control panel. Its alphanumeric screen not only displays the status of your sys- tem, the speaker also provides...

  • Page 3: Table of Contents

    3 t ab l e o f c o n t e n t s table of contents introduction ................................................................ 2 testing the system .................................................... 2 f-64tpbr touchpad controls and indicators .. 4 arming stay: protecting yourself at home.... 6 nig...

  • Page 4

    4 f - 6 4 t p b r t o u c h p ad c o n t r o l s & i n d i c at o r s 1 4 5 6 7 8 9 13 14 20 15 17 18 19 21 22 10 11 12 16 4 2 3 f-64tpbr_oi319a.03_user_... Page 4 friday, september 15, 2006 10:39 composite.

  • Page 5

    5 f - 6 4 t p b r t o u c h p ad c o n t r o l s & i n d i c at o r s lcd window – 32 character lcd displays system status messages, zone descriptions, system troubles, etc. Status light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured, the light will be off ...

  • Page 6

    6 ar m i n g s t ay : p r o t e c t i n g y o u r s e l f at h o m e arming in the stay mode allows you to remain home with the perimeter protection active but with the interior protection off, so that you may move freely within the premises. 1 check the touchpad indicators. The green status light m...

  • Page 7

    7 arming in night mode allows you to remain home with all perimeter and interior protection active--except for the f-64tpbr touchpad pir. If the f-64tpbr touchpad is located in the bedroom, you may move about the bedroom freely. 1 check the touchpad indicators. The green status light must be on-stea...

  • Page 8

    8 ar m i n g s t a y f r o m n i g h t m o d e when already armed in night mode (see page 7), you can arm in stay mode from night mode by simply pressing the stay button. As described on page 6, arming in the stay mode allows you to remain home with the perimeter protection active but with the inter...

  • Page 9

    9 b y p as s i n g f au l t e d z o n e s if you are trying to arm with a faulted zone or zones, the lcd display will clearly indicate which zone(s) are faulted. If you cannot repair the zone(s), they may be temporarily removed from the system, or bypassed, using the following procedure: 1 press the...

  • Page 10

    10 e m e r g e n c y b u t t o n s emergency buttons (only available if programmed). Fire emergency hold down the fire button to alert the central station of a fire emergency. * (fire emergency programmed? Yes no) auxiliary emergency hold down this button to alert the central station of an auxiliary...

  • Page 11

    11 d i s ar m i n g t h e s y s t e m disarming when home (when armed night or stay): to disarm the system. Press the disarm / reset button on the f-64tpbr touchpad. • this function is available only when armed in the night mode or stay mode. • note: if the system is armed in the away mode (interior...

  • Page 12

    12 if an alarm occurs while you are at home: the touchpad siren will sound and the red armed light will flash. The lcd display will read "alarm". Proceed with caution! If you suspect that an intruder may still be in the premises, leave immediately and call authorities from a neighbor's telephone. To...

  • Page 13

    13 if a fire is detected, the siren will sound a distinct pulsating tone and the lcd window will flash the word fire . If a fire alarm does occur: 1 if a fire is in progress, evacuate the premises immediately! Call the fire department from an outside phone. 2 if there is no evidence of a fire, press...

  • Page 14

    14 f i r e p r o t e c t i o n preparing a fire escape plan even with the most advanced fire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your building. Show two exits - a front or back door and a window from each room. (make sure the window wo...

  • Page 15

    15 t o u c h p ad m e n u m o d e the touchpad can provide access to a wide assortment of utility functions, each displayed on the touchpad lcd window in a prompting “yes/no” format. 1 to enter touchpad menu mode, press menu . 2 to skip a function, press no . 3 to select and execute a function, answ...

  • Page 16

    16 continue to chime when system is armed. Change keypad beep volume - when the touchpad buttons are pressed or when an entry warning activates, the touchpad beeper sounds. This function allows the touchpad beeper volume to be adjusted. Press yes to increase, press no to decrease. Selections are hig...

  • Page 17

    17 activate fault find - activates a multiple diagnostic test report. For installer's use only . If accidentally enabled, press reset to exit. Note: this selection only appears with a master i-fob inserted in the touchpad. Reset system tbl - system troubles display and sound at the touchpad. Correct...

  • Page 18

    18 activate download - for installer's use only. If accidentally enabled, press reset to exit. Note: this feature is disabled while armed. Note: this selection only ap- pears with a master i-fob inserted in the touchpad. Activate lost key mode - in the event that the keys to your deadbolt are lost o...

  • Page 19

    19 u s e r p r o g r am m o d e user program mode your installer has programmed into your system a uniquely coded digital master i-fob that can be used to not only disarm the system and silence the siren, but also allows access to the user program mode . User program mode allows you to program vario...

  • Page 20

    20 to the right. 2. Repeat this process to increment (or decrement) the minute as needed. Press en- ter move the cursor to the right and press the yes or no buttons to toggle between " a " and " p " (for am and pm). When finished, press menu to save and proceed to the next option, " enroll master i-...

  • Page 21

    21 to the system. Create a user i-fob as follows: 1. Obtain a new i-fob from your security professional (order part f-ifob ). 2. With “ create user i-fob y/n ” displayed in the lcd window, press " y " and the lcd window will request to insert the new i-fob into the touchpad. 3. After 5 seconds, the ...

  • Page 22

    22 s y s t e m t r o u b l e e r r o r c o d e s your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem should occur, the sys tbl (system trouble) icon will display on the left side of touchpad window along with one o...

  • Page 23

    23 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e04-nn wireless transmitter supervisory failure a problem has been detected with a wireless transmitter. Call installing company for service e05-nn wireless transmitter low battery the battery in a wi...

  • Page 24

    24 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e10-nn touchpad response failure call installing company for service. E11-nn touchpad tamper a keypad or touchpad has been removed from the wall. Call installing company for service if problem cannot ...

  • Page 25

    25 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e19-00 user program memory error call installing company for service. E20-00 dealer program memory error call installing company for service. E21-00 system shutdown call installing company for service...

  • Page 26

    26 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e40-00 rf self test failure a wireless motion sensor on the zone indicated has failed its automatic self test routine. Call installing company for service. E41-nn fire trouble a problem has been detec...

  • Page 27

    27 u s e r i - f o b l i s t • the space below is for recording the names of those in possession of user i-fob's in your system. If an i-fob is lost, be sure to delete its i-fob number from the system (using the procedure on the previous page) as soon as possible. I-fob number area name u __ __ u __...

  • Page 28

    28 federal communications commission (fcc) part 68 statement this equipment complies with part 68 of the fcc rules. On the front cover of this equipment is a label that contains, among other information, the fcc registration number and ringer equivalence number (ren) for this equipment. If requested...

  • Page 29

    29 warning! The limitations of this alarm system while this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variet...

  • Page 30

    30 warning! The limitations of this alarm system (cont'd) • even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect them- selves from the situation. In the case of a monitored alarm system, authorities may not respond appropriately. • this e...

  • Page 31

    31 napco limited warranty napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, at its option, repair or replace any product failing to ope...

  • Page 32

    32 written, are either merged herein or are expressly cancelled. Napco neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall napco be liable for an amount ...

  • Page 33

    33 the following statement is required by the fcc radio and television interference this equipment has been tested and found to comply with the limits for a class-b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interf...

  • Page 34: Notes

    34 notes f-64tpbr_oi319a.03_user_... Page 34 friday, september 15, 2006 10:39 composite.

  • Page 35: Notes

    35 notes f-64tpbr_oi319a.03_user_... Page 35 friday, september 15, 2006 10:39 composite.

  • Page 36

    36 333 bayview avenue amityville, new york 11701 for sales and repairs, (800) 645-9445 for technical service, (800) 645-9440 publicly traded on nasdaq symbol: nssc r © napco 2006 f-64tpbr_oi319a.03_user_... Page 36 friday, september 15, 2006 10:39 composite.