    Gem-p800 installation instructions control panel/communicator wi850a 8/97 © napco 1997 ® wi850a page 1 tuesday, september 16, 1997 08:01.

  • Page 2

    2 wi850a gem-p800 installation instructions *hqhudo ,qirupdwlrq the gemini gem-p800 control panel provides up to 6 hardwired/wireless zones, a 2-wire fire zone and 2 wireless only zones. Up to eight 4-digit user codes can be programmed. Ambush, when selected, uses user 8 code as an ambush code. The ...

  • Page 3

    3 6shflilfdwlrqv &xuuhqw 9rowdjh 5dwlqjv alarm output ---------------------------burg: 12 vdc, 2a (max.) fire: 12 vdc, 65 ma output current limiting --------------burg/fire: 2.25 a aux power: 750 ma combined standby current: --------350 ma maximum (remote pwr, aux output, pgm) 4 hour standby:-------...

  • Page 4

    4 wi850a gem-p800 installation instructions mfg 4-wire smoke detector 2-wire smoke detector smoke detector base sentrol 449at 449c 449crt 449cst 449csrt 449csrh 449csst 449clt 449cslt 449cte 741u 742u 712u 722u 732u 711u 721u 721ut 731u 701u 702u 702re 702ru system sensor 1112 2112 2112t 2112tsrb 21...

  • Page 5

    5 3urjudpplqj wkh 3dqho refer to gem-p800 programming instructions (wi851) defaulting the panel 1. Remove power from the panel. 2. Remove all wiring from terminal 15 (pgm) and terminal 3. 3. Connect terminal 15 (pgm) to terminal 3. 4. Apply power to the gem-p800 control panel. 5. After a few seconds...

  • Page 6

    6 wi850a gem-p800 installation instructions ,qvwdoodwlrq mounting the panel mount the panel close to an unswitched ac source, a cold-water pipe ground, and a tele- phone line connection. Mounting the keypad a keypad should be located near an exit/entry door. To remove the keypad from the backplate, ...

  • Page 7

    7 burglary zone wiring napco’s ez zone doubling tm is simple. Each terminal has 2 zones, use an e (2.2 k) type zone doubling resistor for the primary zone and a z (3.9 k) type zone doubling resistor for the secondary zone. Wire zones as shown in the wiring diagram (pg. 27). All resistors must be ins...

  • Page 8

    8 wi850a gem-p800 installation instructions keypad leds armed led definition armed on instant mode rapid flash zone in alarm flashing status led definition ready to be armed on zone faulted off trouble led definition ac failure flashing system trouble(s) on fire led definition fire alarm flashing fi...

  • Page 9

    9 tone. Enter a valid arm/disarm code, then press . If a valid arm/disarm code is entered, the keypad will beep 6 times, indicating the panel has been disarmed. The red armed led will go out. If an incorrect arm/disarm code is entered, the keypad will sound a 1-second tone, indicating incorrect entr...

  • Page 10

    10 wi850a gem-p800 installation instructions of 1234, program the 4-digit user 1 code through dealer programming [95]. User 1 arm/disarm code is also used to program user codes 2 - 8. By default, the user 1 code cannot be re- programmed by the user. If it is necessary to change the user 1 code, it c...

  • Page 11

    11 keypad will chime on any zone that has not been selected as an exit/entry follower zone, home/ away with delay zones, or 24 hour zone. + user 1 code - user program mode keypad sleep mode on/off enter this command to turn the keypad sounder on/off. When the keypad is in sleep mode all keypad sound...

  • Page 12

    12 wi850a gem-p800 installation instructions remote activation using napco’s quickloader software (version 3.26 or higher), follow the instruc- tions below: from the status screen press f6 select miscellaneous control select enable signal strength logging uploading signal strength information from t...

  • Page 13

    13 cally be unbypassed and any subsequent violations of the zone will cause an alarm condition. [04]24-hour protection a zone that provides protection at all times, whether or not the system is armed. [05]40 ms loop response normally loop response is 750 ms, select this option to change the loop res...

  • Page 14

    14 wi850a gem-p800 installation instructions [15]line cut time-to-fail enable this feature by programming the de- lay time required to declare a line cut failure. Programming 000 will disable line cut detec- tion. [16]wireless supervisory timer a transmitter will send a transmission every time it is...

  • Page 15

    15 [22]miscellaneous features 1 (1) abort delay - program to allow a 15 second delay (except 24 hour zones) after a zone trip before reporting. Disarm the system within 15 seconds to prevent report- ing. (2) easy exit/easy arm- enables command. While the system is armed, entering this command allows...

  • Page 16

    16 wi850a gem-p800 installation instructions 7hohskrqh 1xpehu 3urjudpplqj [30]subscriber id number for 4/2 format enter a 4 digit number. If 3/1 format is required, enter a 3 digit number, then press the key to blank the last digit. [31]telephone number 1 program the phone number to be dialed for te...

  • Page 17

    17 (2) battery restore - program to activate a battery restore report. (3) trouble restore - program to activate a trouble restore report. (4) fire restore - program to activate a fire restore report. [39]opening/closing report, telco 1 select users required to send opening and closing reports to te...

  • Page 18

    18 wi850a gem-p800 installation instructions pager alarm data is the same as 4/2 format with the exception that the 2 digit report code is transmitted before the 4 digit sub- scriber id. [47]leading digits pager pin number - if a pin number is required by the paging system, program the pin number in...

  • Page 19

    19 [63]system report codes program a 2-digit report code for keypad fire, keypad aux, keypad panic, test timer, ac fail, low battery, trouble and fire. [64]system restore code the code sent when a system condition restores. The second digit of the 2-digit restore code is the second digit of the sys-...

  • Page 20

    20 wi850a gem-p800 installation instructions find mode) or saved to the log (see signal strength logging mode - pg. 11). [71-78] wireless transmitters enter the rf id# and the point number that is to be mapped to the zone. Programming example map point 1 of a window door transmitter with an rf id# o...

  • Page 21

    21 are pressed when the system is armed with exit/entry follower zones or home/away with delay zones that have been bypassed. 8 interior program an 8 in the aux 1 and/or aux 2 option to bypass exit/entry follower zones or home/away with delay zones when the or buttons on the keyfob are pressed (only...

  • Page 22

    22 wi850a gem-p800 installation instructions 5. Enter standby mode by entering r . The computer is now in standby site at the site perform the following three steps: 1. Arm the panel. 2. Disarm the panel. 3. Enter . The panel will now call the download computer running pcpreset. Pcpreset will answer...

  • Page 23

    23 6\vwhp 7urxeohv use the system trouble chart on the following page to determine the specific system trou- ble(s). During normal panel operation the system trouble led has the following two modes of operation: steady 1-7 possible trouble groups, ac is present flashing 1-7 possible trouble groups, ...

  • Page 24

    24 wi850a gem-p800 installation instructions keypad beeps or system flashes zone led on system trouble condition cause/action 1 beep 1 ac power failure this trouble will occur if ac power is not present. Ensure that the transformer is connected to an unswitched power source. 2 low battery if there h...

  • Page 25

    25 7urxeohvkrrwlqj 1. The bell output drops to about 3 volts in alarm. The battery/bell circuit is protected by a pc board trace which may have burned open by reversal of the battery leads. It is on the back of the pc board just adjacent to the red & black battery leads. Send in for ser- vice if thi...

  • Page 26

    26 wi850a gem-p800 installation instructions 8. How do i remove keypad sounder on alarm? The keypad sounder follows the burg out- put. If you need to remove the keypad sounder, then you must remove the burg output from that zone. 9. Transmitters not responding? Open transmitter case - keypad should ...

  • Page 27

    27 16 vac 20 va transformer napco trf12 (or equivalent see wi850). Class 2 transformer. Do not connect to switched outlet. -4 +5 +6 gem-p800 terminals 1 2 +3 gem-recv-xp8 red + black e1 e2 rechargeable battery 12 vdc 4ah or 7ah this equipment should be installed in accordance with chapter 2 of the n...

  • Page 28

    28 wi850a gem-p800 installation instructions napco limited warranty napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, at its option, re...