NAPCO GEMC Brochure - page 4
Napco Commercial Combo. Burglary/Fire Kits
GEMC-COMBO255KT
255 Point GEM-C Commercial Combo. Fire/Burg System Kit
•24V Panel, 255 Points via commercial addressable, wireless or conventional fire or burg. devices, 4 on board NACs, 8 partitions (No Loop
Isolator/Extender required)
•7 Amp, 24V Power Supply
•Burg. Module, with power supply with built in bus isolator for complete separation of fire and burg power and battery standby operation
•Built in horn/strobe synch. module on each NAC
•Built in dual line communicator; dual onboard serial ports
•Quickloader up/downloading including remote smoke obscuration reporting
•Locking, Large Red Enclosure, 16 x 25” reversible door, with 14.25” x 25” base. Houses up to 32Ah battery backup.
•Menu-driven LCD Fire Keypad mounts anywhere on bus (Also, full keyswitch support)
GEMC-COMBO128KT
128 Point GEM-C Commercial Combo. Fire/Burg System Kit
As above, but with
•24V Panel, 128 Points via commercial addressable, wireless or conventional fire or burg. devices, 4 on board NACs, 8 partitions (No Loop
Isolator/Extender required)
GEMC-COMBO32KT
32 Point GEM-C Commercial Combo. Fire/Burg System Kit
Similar to above, but with
•24V Panel, 32 Points via commercial addressable, wireless or conventional fire or burg. devices, 2 on board NACs, 8 partitions (No Loop
Isolator/Extender required)
•Locking, Medium Red Enclosure, 16 x 17” door, with 14.25” x 16” base. Houses up to 16Ah battery backup.
Napco Commercial Fire Kits
GEMC-FW-255KT
255 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
•24V Panel, 255 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A notification
power
•7 Amp, 24V Power Supply
•Built in horn/strobe synch. module on each NAC
•Built in dual line communicator; dual onboard serial ports
•Quickloader up/downloading including remote smoke obscuration reporting
•Locking, Large Red Enclosure, 16 x 25” reversible door, with 14.25” x 25” base. Houses up to 32Ah battery backup.
•Menu-driven LCD Fire Keypad mounts anywhere on bus. (Also, full keyswitch support)
GEMC-FW-128KT
128 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
As above, but with
•24V Panel, 128 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A notification
power
GEMC-FW-32KT
32 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
Similar to above, but with
•24V Panel, 32 Points via commercial addressable, wireless or conventional fire devices, 2 on board NACs providing up to 4A notification
power
•Locking, Medium Red Enclosure, 16 x 17” door, with 14.25” x 16” base. Houses up to 16Ah battery backup.
Commercial Fire & Burglary Accessories and Options
GEMC-BM/PS
Burg Module with 12V power supply provides isolated 4-wire burg bus for burg keypads and devices, plus 12V power output for aux. devices. In-
dependent Burg. Bell output. Complete separation of fire and burg power, plus indep. burg. battery connection and charger for indep. burg. standby
operation in power failure.
GEMC-BM
Burg Module, isolated 4-wire burg bus for burg keypads and devices, plus 12V power output for aux devices. Indep. Burg bell output.
GEMC-FW-SLC
Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices. Up to 2 connect to GEM-C panel.
GEMC-BSLC
Addressable SLC Burg Module, supports up to 128 addressable SLC burg devices. Up to 2 connect to GEM-C panel.
GEMC-F8ZCPIM
Conventional 8-zone 2-wire fire input module. Plugs into GEM-C panel, for conventional 2-wire smokes or any conventional fire detection device.
Burglary Peripherals
GEMC-BK1
LCD Burglary Keypad for Combo. System, with 4-zone EZM built in (Requires GEMC-BM or BM/PS Module.)
GEMC-BSLC-4PT
Addressable SLC 4 point input expansion module
GEMC-BSLC-1PT
Addressable SLC 1 point input expansion module
GEMC-BSLC-DT
Addressable SLC Commercial Dual Tech Microwave/PIR, 40 x 40’
GEMC-BSLC-PIR
Addressable SLC Commercial PIR, 50 x 50’
GEMC-BSLC-RLY
Addressable SLC Commercial 1 point output module
GEMC-WL-PIR
Gemini Commercial Wireless PIR, 50 x 50’
GEMC-WL-GB
Gemini Commercial Wireless Glassbreak, Acoustic 25’
GEMC-WL-DT
Gemini Commercial Wireless Dual Tech Microwave/PIR, 40 x 40’
Fire Peripherals
GEMC-FK1
LCD Fire Red Keypad
GEMC-WL-SMK
Gemini Commercial Wireless Smoke, Photoelectric
GEMC-WL-HEAT
Gemini Commercial Wireless Heat, 135º F
Common Peripherals – For Commercial Fire and/or Burglary Systems
GEMC-WL-WD2
Gemini Comml Wireless 2-input module converts any UL listed device into a UL wireless device (ex., pull stations or sprinkler supervisories.)
GEMC-REVC
Gemini Commercial Wireless 255 point RF Receiver (up to 4 per system, max.)
GEMC-EZM8
8-point expansion module
GEMC- FPRINT
Parallel printer module
GEMC-RM3008
8 Form C Relay Output Module
GEMC-NL-MOD
Internet Reporting Module
GEMC-RS232
RS232 Adapter for serial output from GEMC Panel
GEMC-OUT8
PGM Output Module, 8 open collector PGM outputs
GEMC-KOTAMPERKT
Merchantile Tamper Kit, for large panel enclosures, supervised.
(Not necessary if housing is recess-mounted.)
Firewolf Peripherals
FWC-FSLC-SMK
Addressable Analog SLC Smoke, photoelectric, head**
FWC-FSLC-HEAT
Addressable Analog SLC Heat, 135ºF, head**
FWC-FSLC-DUCT
Addressable SLC Duct smoke detector, photoelectric
FWC-FSLC-EZM2
Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indepent contact monitoring circuits, for pull
stations, water flow and other dry contact alarm initiating devices.
FWC-FSLC-EZM1
Addressable SLC 1-input conventional module, similar to usage above.
FWC-FSLC-CZM
Addressable SLC single module, for montoring of dry contacts, ie., pull stations and conv. smokes
FWC-FSLC-RM2
Addressable SLC 2-output module (requires 1 SLC address)
FWC-FSLC-ISO
Addressable SLC Short Circuit Module. (Optional use, for certain apps. only; meets Class A, Style 7 loop reqts.)
FWC-FSLC-SOM1
Addressable SLC Fire supervised output module. Application examples: elevator recall, HVAC shutdown, add’l NAC output with power supply
FWC-FSLC-PULL
Addressable SLC Fire Pull Station
FWC-FSLC-PROG2
Tool for address-programming SLC devices
FWC-FSLC-SMK6B
** Smoke/Heat 6" Base, required for FWC-FSLC- SMK and –HEAT devices
Options
GEMC-12V2APS-CF
12VDC Power Supply for Fire Bus, remote supervised. Direct 120VAC connection, supports 2ea. 12V, 7Ah standby batteries.
GEMC-12V2APS-R
12VDC Power Supply for Burg. Bus, remote supervised. Powered by supplied 16.5V, 50VA plug-in transformer, supports 2ea. 12V, 7AH standby
batteries.
GEMC-NAC6
Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16” can, connects to 120VAC, supports 32Ah standby batts.
Supervised, fire bus connection. System Sensor and Wheelock NAC synch. (5 per system, for 20 add’l NAC circuits total.)
GEM-ACM1D
Access Control Module (with power supply, provision for back up battery, in enclosure, plug-in transformer), 1 door kit
GEM-2D
Access Add-on 2 door plug–in PCB for expansion of door capacity in above.
NAPCO COMMERCIAL GEMINI-C & FIREWOLF SERIES SYSTEM ORDERING INFORMATION
1-800-645-9445 www.napcosecurity.com/newproducts.html ©
Napco August 2010. Specifications subject to change A593A