    Installation instructions hardwire wireless g e m - p 1 6 6 4 control panel/communicator wi1424a 1/06 © napco 2006 r for use with "classic" keypads (gem-rp1cae2, gem-rp2ase2, gem-rp3dgtl and gem-rp4rfc/gem-rp4c) and with "k series" keypads (gem-k1ca, gem-k2as, gem-k3dgtl, and gem-k4rf/gem-k4) "k ser...

  • Page 2

    This manual includes features which are only available in gem-p1664 control panel firmware version 1.0 or later. Napco security systems, inc. 333 bayview avenue, amityville, new york 11701 for sales and repairs, call toll free: (800) 645-9445 for direct line to technical service, call toll free: (80...

  • Page 3

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 3 table of contents introduction ..................................................... 4 general description ................................................ 4 features .....................................................

  • Page 4

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 4 introduction general description napco's gemini gem-p1664 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up t...

  • Page 5

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 5 communicator features compatible with all major receiver formats, including 4/2, sia and point id (except radionics modem ii). Rotary dial and touchtone tm with rotary backup. Three 20-digit telephone numbers. Backup ...

  • Page 6: For All Ul Installations

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 6 specifications gem-p1664 o perating temperature: 0-49°c (32-120°f) input power: 16.5-18.0 vac via class 2 plug-in 20va, 40va or 50va transformer loop voltage: 10-13vdc loop current: 3ma without zone doubling, 2.4ma wi...

  • Page 7

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 7 ordering information system components gem-p1664: residential ul-listed burg and fire control panel. Gem-rp1cae2: 32-character lcd burg & fire keypad with 4 eol zones. Gem-rp2ase2: lcd burg & fire keypad with remote p...

  • Page 8

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 8 smoke detectors, 4-wire: 1. Esl 445at, 445c, 445ct, 445cr, 445crt 2. Hochiki america slg-12 with ybc-rl4-ra base 3. System sensor 2312/24t; 1412; 1412th; 2412th subtract total smoke-detector alarm current from availab...

  • Page 9

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 9 installation mounting control panel choose a mounting location accessible to (a) a continuously-powered ac source, (b) system ground, a steel or copper ground rod, ideally no further away than 10 feet, and (c) telepho...

  • Page 10

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 10 wiring wire keypad(s), zones, expansion zone modules and output devices as shown on the wiring diagram. Note that the wiring diagram contains important information not available elsewhere in this manual. Adding expan...

  • Page 11

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 11 testing the system after installation is completed, test the system as follows. 1. Call the central station to inform them of the test. 2. Initiate an alarm, preferably on a zone that activates a steady siren, and ve...

  • Page 12

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 12 wiring connections battery the red (+) and black (-) flying leads must be connected to a 12vdc 4-7 ah rechargeable battery, to serve as backup power in the event of ac power failure. Note: to calculate the available ...

  • Page 13

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 13 additional ezms available devices 1. Keypads: gem-rp2as & gem-rp1cae2 2. X-10 interface: gem-x10 3. Wired zone expander: gem-ezm816 4. Wireless receivers: gem-recv8, gem-recv16 & gem-recv96 5. Relay module: rm3008 6....

  • Page 14

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 14 the basic zone configuration for the gem-p1664 is 8 zones. Connect as shown above to terminals 13-24. Normally closed (n. C.) devices may be wired in series or normally open (n.O.) devices may be wired in parallel. U...

  • Page 15

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 15 two-wire smoke detectors can only be connected to zones 7 and 8. To use them, select fire zone programming option and select 2-wire smoke detector programming option for the desired fire zone 7 or 8 (refer to the gem...

  • Page 16

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 16 model 368 cord telephone lines connect the model 368 cord as follows: 26 (red = telco ring), 27 (green = telco tip), 28 (gray = home ring) and 29 (brown = home tip). Insert the modular plug into an approved usocrj31x...

  • Page 17

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 17 keypad configuration mode this section will focus on configuring the gem-rp1cae2/gem-k1ca and gem-rp2ase2/gem-k2as keypads. We recommend that either a gem-rp1cae2 or a gem-k1ca keypad be used for programming. Keypad ...

  • Page 18

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 18 compatibility number (not applicable) this feature is not compatible with the gem-p1664 con- trol panel. Do not change this setting. Press the a or r button to continue or press the c button to exit. Ezm address the ...

  • Page 19

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 19 configuring the gem-rp2ase2/gem-k2as and gem-rp3dgtl/gem-k3dgtl keypads up to 7 gem-rp2ase2/gem-k2as keypads may be connected to the panel (keypads 1–7). Each must be configured for a keypad address. In addition, the...

  • Page 20

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 20 basic operation this section provides a brief overview of system operation. For detailed operation, refer to the user's guide furnished with the keypad (see page 7 for a listing of user guides for each keypad) and to...

  • Page 21

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 21 b asic op eratio n r (or a ) and b . Change the zone number using keys 0 through 9 . Enter two digits for the zone number (after entering the first digit, the cursor will automatically advance to the second digit). W...

  • Page 22

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 22 basic op eratio n auto arming (not for ul installations) auto arm allows the user to automatically arm the system at a specified time of the day and on specific days of the week. Schedule a specific closing time on a...

  • Page 23

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 23 global arm/disarm in a partitioned system, any of 4 secured areas may be armed (or disarmed) from the manager's mode (if en- abled). The manager's mode, is a low-security mode of operation. It provides quick access t...

  • Page 24

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 24 display zn bypassed press yes button to display zones that have been deactivated. Press next button to scroll through the zones. Display zn directory press yes button to display a list of all programmed zone descript...

  • Page 25

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 25 b asic op eratio n activate fault find (available with the dealer program code) this troubleshooting aid will help the installer locate swingers. When accessed, two things occur: the loop response of each zone is set...

  • Page 26

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 26 keypad messages the gem-rp1cae2/gem-k1ca keypads can display the below messages. The gem-rp2ase2/gem-k2as will display similar abbreviated messages that may scroll through two screens. Note: see page 7 for a listing ...

  • Page 27

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 27 glossary note: displayed messages shown are for the gem-rp1cae2 and/or gem-k1ca keypads. Other keypad messages are similar but abbreviated. Refer to the gem-p1664 programming manuals (wi1422 and wi1423) for specific ...

  • Page 28

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 28 alarm outputs in ul installations, (1) see time selection for timeout requirements; (2) fire zones must be programmed for pulsealarm output, and the option "change pulse alarm to cadenced alarm" must be programmed. N...

  • Page 29

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 29 auto arm if not closed at end of window. When the start time is reached, the display will notify the occupants that an auto-arm will be initiated in the notification period length of time. After that period has expir...

  • Page 30

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 30 the "pre-alarm warning", then no report will be sent and no messages will be displayed at the keypad. If the area is disarmed during the abort-delay, then an "alarm canceled' will be displayed at the keypad and no re...

  • Page 31

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 31 ask the central station which of these formats to use. Two-digit or 4/2 format. Some central-station receivers require that a four-digit account code followed by a two-digit alarm code be sent in each report. Example...

  • Page 32

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 32 on an open loop. Note: (1) if a zone is programmed for both "day zone open" and "day zone short", either condition must be reset before the other can activate. (2) day zone short will not function if no eol resistor ...

  • Page 33

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 33 security applications. When one or more zones is bypassed, the bypassed reminder on the gem-rp1cae2 keypad will display. Disable code required for easy bypass is enabled by default. Disable function-mode download see...

  • Page 34

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 34 enable alarm output on telco fail only when area(s) armed (alarm output only when armed) allow telephone line fault test to produce an alarm output only when armed. Note: requires "system features: alarm output", "te...

  • Page 35

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 35 zone will go into an instant alarm. If the panel is armed with the entry delays canceled (instant protection), any violation on the exit/ entry zone or the exit/entry follower zone will cause an immediate alarm. Exit...

  • Page 36

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 36 inhibit system trouble audible at keypad (do not program in ul installations) for installations where an audible during a system trouble is not desired, an option, inhibit system trouble audible can be enabled. Regar...

  • Page 37

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 37 jp1: cut to enable keypad tamper. Jp3: note different zone terminal wiring required as shown in wiring diagram. W1 & w3: cut both to disable touch pad backlighting. W2: cut to disable lcd backlighting. Keypad jumpers...

  • Page 38

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 38 lug e15 see "e" lugs memory failure a user or dealer memory error will cause the sounder to pulse, the " sys/trbl " reminder to flash, and the display to read " system trouble/e19-00 service " or " system trouble/e20...

  • Page 39

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 39 installations, do not program more than one "d" before the telephone number. See backup report on telco 2; report telco 3 (double or split reporting). Also see access number for outside line; telephone numbers. Print...

  • Page 40

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 40 external remote mounting, and one module may be used with the gem-p1664 control panel. Use the rm3008, rb3008 or the gem-out8 for 16 independent programmable active low outputs for controlling 32 relay events, which ...

  • Page 41

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 41 sensor watch it supervises designated zones for a lack of activity and will cause a system trouble e-22-xx sensor activity fail if no activity is detected for the programmed period of time. The sensor watch should be...

  • Page 42

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 42 swinger shutdown: swinger shutdown is a common term used in the burglary alarm industry. It is a feature of an alarm panel that prevents multiple false alarms from being generated from faulty detectors (or wiring) by...

  • Page 43

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 43 positive or negative temperature. If the temperature of 0 degrees is required, "negative zero" (-0) degrees must be used (+0 or an empty location is not a valid temperature). To simulate the sensor module, a power su...

  • Page 44

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 44 trouble (open and/or short circuit) on a day zone is indicated by a pulsing sounder; display the day zone(s) in trouble on the lcd. Keypad indications are reset by the c button unless reset day zone with arm/disarm i...

  • Page 45

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 45 glossar y 255 is entered the system will display 000 to request a re-entry. Note: only the panel zones’ integration times are programmable. Ezm’s will continue to use either 50 or 750 ms as selected by jumpers on the...

  • Page 46

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 46 standby-battery calculation worksheet use the procedure given below to determine the required standby battery capacity in ampere-hours (ah). Note: it is not totally accurate to merely multiply the combined standby cu...

  • Page 47

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 47 wiring legend should removal of the circuit board be necessary, use this wiring legend to relocate wire leads to their proper terminals. Enter wire identification number or color code in wire number column and enter ...

  • Page 48: Function Mode

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 48 keypad programming modes ke yp ad program m ing modes: fu nction mode note: functions that are not active, not programmed and/or not applicable to user’s area option will be suppressed and will not display. Due to sp...

  • Page 49: Dealer Mode

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 49 ke yp ad program m ing modes: de aler mode dealer mode condition disarmed armed keypad message if zone faults? * y n/a display zn faults if zone bypasses? Y y display zn bypassed always * y y display zn directory if ...

  • Page 50: Easy Menu Mode

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 50 ke yp ad pr ogr ammi ng modes : eas y me nu mode easy menu mode * initial configuration only (new or memory cleared panel); suppressed thereafter. Normal entry mode for previously programmed panel starts at “ # area ...

  • Page 51: User Mode

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 51 ke yp ad program m ing modes: us er mode user mode * not avialable in gem-rp2as/rp2ase/rp2ase2 keypads. To enter date and time, gem-rp1cae2 keypad (version 6 or greater) must be used. User codes zone descriptions * (...

  • Page 52: Keypad Configuration Mode

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 52 ke yp ad programming mode s: ke yp a d configur ati o n mode keypad configuration mode gem-rp1ca/1cae/1cae2/ gem-k1ca keypads press r (or a ) button enter factory code: 11123 configure: • keypad beep on/off • entry s...

  • Page 53

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 53 cp-01 quick reference chart--sia false alarm reduction feature description programming address location cp-01 features are enabled with one global selection in the panel. Enabled in ez programming exit delay. Minimum...

  • Page 54

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 54 duress code. The panel will not allow duplicate user codes to be programmed. Every user program code may now be selected as an ambush code for area 1 or area 2 by entering a _5 in the area 1 options or area 2 options...

  • Page 55

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 55 the factory program of the gem-p1664 will change with the release of the new version that complies with security industry as- sociation false alarm reduction control panel-01 standard (sia far cp-01). Out of box pane...

  • Page 56

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 56 10. Alarm and pulse alarm time-outs are 15 minutes. 11. Chime is set to 2 seconds. 12. Change pulse alarm to cadence alarm is enabled. 13. Auto reset after burglary output timeout is enabled. If the answer to the que...

  • Page 57

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 57 fcc statement this equipment generates and uses radio-frequency energy and, if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and ...

  • Page 58: Notes

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 58 notes.

  • Page 59

    L napco security systems x gem-p1664 installation instructions wi1424a 1/06 page 59 gem-p1664 wiring diagram gem-p1664 wiring diagram 550ma 550ma (1) 12 model-delay-sec (+) +.

  • Page 60

    X gem-p1664 installation instructions l napco security systems wi1424a 1/06 page 60 napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, a...