Napoleon GI3016-N Installation And Operation Instructions Manual

Manual is about: GAS-FIRED VENTED ROOM HEATER INSERT NATURAL AND PROPANE GAS MODEL

Summary of GI3016-N

  • Page 1

    1 w415-0171 / d / 01.06.04 installer: these instructions must be conveyed to and remain with the homeowner. Wolf steel ltd., 24 napoleon rd., barrie, on l4m 4y8 canada • (705)721-1212 • fax(705)722-6031 www.Napoleonfireplaces.Com • ask@napoleon.On.Ca certified under canadian and american national st...

  • Page 2

    2 w415-0171 / d / 01.06.04 10-11 operation / maintenance operating instructions fresh air damper system maintenance 11 blower installation blower replacement instructions 11 adjustments venturi adjustments pilot burner adjustment 12-13 replacements ordering replacement parts replacement parts access...

  • Page 3

    3 w415-0171 / d / 01.06.04 napoleon gas fireplaces are manufactured under the strict standard of the world recognized iso 9001 : 2000 quality assurance certificate. Napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their wor...

  • Page 4

    4 w415-0171 / d / 01.06.04 the fireplace, when installed, must be electrically con- nected and grounded in accordance with local codes. In the absence of local codes, use the current csa c22.1 canadian electrical code in canada or the ansi/nfpa 70 national electrical code in the united states. The b...

  • Page 5

    5 w415-0171 / d / 01.06.04 do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. Porcelain enamelled compo- nents must be handled with care. The baked-on finish is glasslike. If struck, it will chip! Touch-up paint is available through your napoleon dealer. Levellin...

  • Page 6

    6 w415-0171 / d / 01.06.04 remove the se- curing screws lo- cated on either of the firebox sides as illustrated. Remove protective plastic wrap from all four panels. Centre the rear brick panel against the back of the firebox. Place the left brick panel against the left side of the firebox, ensuring...

  • Page 7

    7 w415-0171 / d / 01.06.04 figure 10 figure 11 positioning the logs improperly will cause flame impingement and carboning. Phazer tm logs and charcoal embers, exclusive to napo- leon fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to c...

  • Page 8

    8 w415-0171 / d / 01.06.04 attach the lower glass bracket. Seat the glass inside the bracket and using two screws attach the upper glass bracket, as shown. Assemble the flashing and mount to the inside of the outer shell using 4 securing screws (supplied with the louvre kit). Remove the backing of t...

  • Page 9

    9 w415-0171 / d / 01.06.04 with the bay chassis on a flat surface, insert the front glass (bottom first) and centred to the mitred edges of the chassis. Fit the bevelled edge of the each side glass piece tightly to either edge of the front glass. Secure the glass by bend- ing up the retainer tabs at...

  • Page 10

    10 w415-0171 / d / 01.06.04 if your masonry fireplace is equipped with a fresh air inlet in the floor of the firebrick chamber, the insert is able to take outside air directly into the unit through an opening in its base thereby eliminating the need to use preheated room air for combustion. The flow...

  • Page 11

    11 w415-0171 / d / 01.06.04 3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly. (right brick panel must be removed in order to facilitate burner removal) 4. Check to see that the pilot flame is large enough to engulf t...

  • Page 12

    12 w415-0171 / d / 01.06.04 # part no.Description 1 gz-551 replacement blower 2 w725-0036 natural gas valve c/w adjustable regulator 2 w725-0037 propane gas valve c/w adjustable regulator 3 w455-0004 #36 dms natural gas burner orifice 3 w455-0003 #54 dms propane gas burner orifice 3 w455-0013 #37 dm...

  • Page 13

    13 w415-0171 / d / 01.06.04.

  • Page 14

    14 w415-0171 / d / 01.06.04 gas piping is undersized. Pilot goes out while standing; main burner is in 'off' position. - turn on all gas appliances and see if pilot flame flutters, diminishes or extinguishes, especially when main burners ignite. Monitor supply pressure. - check if supply piping size...

  • Page 15

    15 w415-0171 / d / 01.06.04 main burner goes out; pilot goes out. A - refer to "main burner goes out; pilot stays on" b - chimney down-drafting - wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer. Open windows and/or doors. Start firepla...

  • Page 16

    16 w415-0171 / d / 01.06.04 wolf steel fireplace service history this fireplace must be serviced annually depending on usage. Date service technician name service performed special concerns dealer name.