    Installer: these instructions must be conveyed to and remain with the homeowner. Fax: (705)722-6031 email: ask@napoleon.On.Ca web: www.Napoleon.On.Ca ws-415-108 / 09.29.97 model os10 installation and operation instructions for oil-fired cast iron stove wolf steel ltd., rr#1, 9 napoleon rd., barrie, ...

  • Page 2: Table Of Contents

    2 table of contents pg 2-4 introduction warranty general information care of enamelled parts care of glass 4-7 installation unit specifications locations and clearances safety precautions draft air outside air chimney specifications chimney connection chimney installation adding chimney sections 7 f...

  • Page 3

    3 napoleon oil stoves are manufactured under the strict standard of the world recognized iso9001 quality assurance certificate. Napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete stove is thoroughly i...

  • Page 4

    4 general information nominal heat oil consumption ** chimney draft required weight flue outlet output max speed min speed max speed min speed outside diameter 34,130 btu/hr .275 us gal/hr .055 us gal /hr 20 pa 6 pa 260 lbs 5 inches 10 kw 1.25 litre/h ¼ litre/h @ .08 w.C.G @.024 w.C.G. 118 kg 120-12...

  • Page 5

    5 location and clearances if the stove is to be installed on a combustible floor, it must be placed on a approved noncombustible hearth pad, that extends the full width and depth of the unit - 24½" x 21½" (620 mm x 544 mm). Maintain these minimum clearances to combustibles: a (side wall to side of s...

  • Page 6

    6 chimney specifications if the chimney is ‘cold’, the normal combustion cycle will not work. A cold chimney may be caused by disuse, being too large, not insulated, being external or not high enough. Exterior chimneys cool rapidly, causing poor draft and condensation. Chimney connector the stove sh...

  • Page 7

    7 adding chimney sections add chimney sections, twist locking (clockwise) securely, to the required height. Safety requirements dictate that the chimney must be at least 3 feet (915 mm) higher than the highest point where it passes through the roof and at least 2 feet (610 mm) higher than the highes...

  • Page 8

    8 operating instructions understanding your oil stove furnace oil is fed from the tank to the burner floor (a) where is it ignited by means of a firestarter. The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel. Oil will only burn as a vapour not a...

  • Page 9

    9 lighting instructions proceed once installation is complete and all necessary instructions have been followed: when lit for the first time, the stove will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing and the "burn-in" of internal paints and lubrica...

  • Page 10

    10 b a c adjustments oil flow adjustments always burn the stove on low for at least 15 minutes before attempting to adjust the flow. Turn the screw only a quarter turn at a time. Wait 10 to 15 minutes between adjust- ments to allow the fire to stabilise. The oil flow setting is done by the manufactu...

  • Page 11

    11 a - control knob b - thermostat control c - oil level regulator d - safety lever e - filter f - main float g - safety float h - filter cavity a b e h g f c d figure 13 maintenance weekly - descale push and pull the de-scaling lever in and out as well as turning slightly at the same time completel...

  • Page 12

    12 door gasket replacement check the door gasket periodically to ensure the seal is functioning properly and the door fits tight. Replace the gasket if necessary. Replacements ordering replacement parts contact your dealer or the factory for questions concerning prices and policies on replacement pa...

  • Page 13

    13.

  • Page 14

    14 trouble shooting problem test solution symptom flames extinguish during lighting. Very cold chimney. No draft established - leave door ajar until fire has caught. Fire extinguishes during use. Fuel tank is empty. - fill tank flame is excessely large, smokey and sooty. Fuel adjustment made too qui...