  • Page 1

    Installer : these instructions must be conveyed to and remain with the homeowner. Certified in canada to can/csa c22.2 no. B140.3, b140.1, b140.0 and in the united states conforms to ul std 307a, ansi/ulstd 896 installation and operation instructions for oil-fired cast iron stove mobile home approve...

  • Page 2: Introduction

    Please retain this manual for future reference introduction warning • the stove is an oil-fired stove. Do not burn wood or other materials in this stove. • adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ign...

  • Page 3

    Napoleon oil stoves are manufactured under the strict standard of the world recognized iso9001 quality assurance certificate. Napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete stove is thoroughly ins...

  • Page 4: Installation

    General information nominal heat output oil consumption ** chimney draft required weight flue outlet inside diameter max speed min speed max speed min speed 27,300 btu/hr .25 us gal/hr .073 us gal/hr .06" w.C. .024" w.C. 220 lbs 5 inches 8 kw 0.96 liter/h 0,28 liter/h 15 pa 6 pa 100 kg 125 mm ** 1 p...

  • Page 5

    Location and clearances if the stove is to be installed on a combustible floor, it must be installed on sheet metal or a tile. The oil drip tray, 72636 (not supplied) is a suitable substitute for either of these two pads. Maintain these minimum clearances to combustibles (fig. 2) : a 10 inches (250 ...

  • Page 6: Installation

    Installation do not install in a room used for sleeping. The stove must be firmly bolted to the floor with 1/4 inch lag bolts (fig. 8, p. 8). Minimum clearances to combustibles are as shown in figure 2, page 5. Venting the chimney must be installed in accordance with the manufacturer’s instructions....

  • Page 7: Mobile Home Installation

    There are two types of chimney connectors : a single wall chimney connector may be used for top connection : this connector must be 316 grade 26 gauge stainless steel or 1 mm vitreous enamelled steel and with a 5" (127 mm) diameter. Secure the connector joints with 3 sheet metal screws. The joints a...

  • Page 8: Finishing

    Finishing mounting flue collar and blanking plate the stove is supplied with a connection flue at top. The flue collar is reversible (2 screws) so that the smoke exit can be done at rear or on the top (figure 12 and figure 13, page 9). Leveling the stove four adjusting bolts with caps are supplied a...

  • Page 9

    3 1 4 2 6 5 3 1 1 2 5 3 4 6 7 8 figure 12 figure 13 figure 14 figure 12 - top flue outlet figure 13 - rear flue outlet 1. Blanking plate 2. Burner 3. Flue collar 4. Baffle 5 reflector 6 optional mirrors figure 14 - operating devices 1. Control knob 2. Intake collar 3. Safety lever 4. Control filter ...

  • Page 10: Operating Instructions

    Operating instructions understanding your oil stove furnace oil is fed from the tank to the burner floor (a) where is it ignited by means of a firestarter. The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel. Oil will only burn as a vapour not a l...

  • Page 11: Adjustments

    Shut down 1. Turn the control knob to “0" setting. 2. Lift the safety lever. 3. Turn off the oil tank fuel supply valve. The oil tank fuel supply valve should always be shut off when the oil stove is not in operation. Adjustments oil flow adjustments the oil flow setting is done by the manufacturer ...

  • Page 12: Maintenance

    Maintenance seasonal maintenance weekly - descale push and pull the de-scaling lever in and out as well as turning slightly at the same time completely two or three times. Push in for normal burner operations or before relighting. Every 3 to 4 months - clean burner remove all three catalyser compone...

  • Page 13

    Replacements ordering replacement parts contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. Model...

  • Page 14

    1 2 3 4 5 6 7 8 9 1 0 6 1 1 3 2 1 1 5 1 6 1 7 1 8 1 9 6 0 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 6 2 6 4 2 0 4 0 6 5 6 1 6 0 1 0 6 0 6 0 1 6 3 5 5 5 5 3 3 5 5 6 0 1 4 1 1 1 2 7 8 0 8 0 8 1 1 ...

  • Page 15

    Notes document n° 1043-1 ~ 15/01/2002 15.

  • Page 16: Trouble Shooting

    Symptom problem test solution flames extinguish during lighting. Very cold chimney. No draft established - leave door ajar until fire has caught. - check air supply in the room fire extinguishes once firestarter has burnt off. Fuel tank is empty - fill tank fuel valve is closed. - open valve main ca...