Description
1. Intake Filter
2. 1st stage
3. Inter-cooler 1st stage
4. 2nd stage
5. Inter-cooler 2nd stage
6.
3rd stage
7.
Inter-cooler 3rd stage
8.
4th stage
9.
Inter-cooler 4th stage
10. Oil indicator
4. TECHNICAL DATA
Compressor unit
ATLANTIC 100
Operating pressure
PN 200
PN300
Delivery *
100 L/min.
100 L/min.
Final pressure safety valve
225 Bar
330 Bar
Compressor block
ATLANTIC 100
Number of stages
4
Number of piston
4
Cylinder bore stage 1
60 mm
Cylinder bore stage 2
38 mm
Cylinder bore stage 3
19 mm
Cylinder bore stage 4
9,5 mm
Piston stroke
23 mm
Intermediate pressure stage 1
2,5 Bar
Intermediate pressure stage 2
15 Bar
Intermediate pressure stage 3
55 - 65 Bar
Intermediate pressure stage 4
225 - 330 Bar
Oil capacity
0,350 L.
Oil Type
SHELL CORENA P150
Max permissible ambient temp.
-5°C Min. +45°C Max. (+25°F Min. +113°F Max.)
Max permissible inclination of compressor
20°
Max dampness
80%
Max sea level
2000 m sea level
Weight
25 Kg.
Drive engine
Mono phase
Three phase
Type engine
110–240 Volt / 50–60 Hz
230-400 Volt / 50-60 Hz
Power
3,0 Hp 2poli
Speed
2850 r.p.m.
Type of enclosure
IP 55
Current rating
16,5 A (240 Volt) – __,_ A (110 Volt)
Petrol engine
ROBIN EX17 6,0 Hp 4 Stroke
Switch on/off
MANUAL
Cubic capacity
169 ml.
Power
2,9 Kw-4,00 HP / 3600 r.p.m.
5. SAFETY MEASURES
5.1. Fundamental safety notices:
Important instructions concerning the endangerment of personnel, technical safety and operating safety will be specially emphasized by
special marks placing on the machine.
For safety reasons you can find some components mounted on the compressors in order to prevent damages. These parts must not be
changed or removed in any case. Before please consult our technician.