National Instruments NI 4070 Getting Started Manual - 4. Installing The Software

Manual is about: NI Digital Multimeters

Summary of NI 4070

  • Page 1

    October 2007 373120l getting started guide ni digital multimeters this document contains english and japanese language instructions. This document explains how to install, configure, test, and set up the ni pcmcia-4050, ni pxi/pci-4060, ni pxi/pci/pcie/usb-4065, ni pxi/pci-4070, ni pxi-4071, and ni ...

  • Page 2: Conventions

    Ni digital multimeters getting started guide 2 ni.Com ni-dmm instrument driver ........................................................................................................ 22 ni-dmm examples ....................................................................................................

  • Page 3

    © national instruments corporation 3 ni digital multimeters getting started guide ni 4065 refers to the ni pxi/pci/pcie/usb-4065. Ni 4070 refers to the ni pxi/pci-4070. Ni 4071 refers to the ni pxi-4071. Ni 4072 refers to the ni pxi-4072. Ni 407x refers to the ni 4070, ni 4071, and ni 4072. Dmm digi...

  • Page 4: 2. Unpacking

    Ni digital multimeters getting started guide 4 ni.Com 2. Unpacking (pci, pci express, and pxi devices) the dmm ships in an antistatic package to prevent electrostatic discharge (esd). Esd can damage several components on the dmm. Caution never touch the exposed pins of connectors. To avoid damage wh...

  • Page 5: 4. Installing The Software

    © national instruments corporation 5 ni digital multimeters getting started guide other required items in addition to the kit contents, you also need the following: ❑ 1/8 in. Flathead screwdriver ❑ one of the following configurations: – (pci devices) —a desktop computer with its documentation and on...

  • Page 6: 5. Installing The Hardware

    Ni digital multimeters getting started guide 6 ni.Com 5. Installing the hardware cautions unless you are using a usb device, you must power off the pc or pxi chassis before installing the dmm hardware. To prevent damage due to esd or contamination for all pxi, pci, and pci express devices, handle th...

  • Page 7

    © national instruments corporation 7 ni digital multimeters getting started guide installing a pxi express compatible dmm to determine if your dmm is a pxi or pxi express compatible dmm, refer to figure 2. To install a pxi express compatible dmm, refer to the installing a pxi dmm section using a pxi...

  • Page 8

    Ni digital multimeters getting started guide 8 ni.Com installing a pci dmm to install a pci dmm, refer to figure 3 and complete the following steps. Figure 3. Pci installation 1. Power off and unplug the pc. 2. Remove the pc cover. 3. Insert the pci dmm into an open pci slot. 4. Secure the pci dmm w...

  • Page 9

    © national instruments corporation 9 ni digital multimeters getting started guide installing a pci express dmm to determine pci express slots, refer to figure 4. To install a pci express dmm, refer to the installing a pci dmm section using any pci express slot. Figure 4. Pci express slots installing...

  • Page 10

    Ni digital multimeters getting started guide 10 ni.Com usb cable strain relief you can choose between two strain relief options for your usb dmm: • cable strain relief groove method—press the usb cable into one of the two grooves on the underside of the usb device. Choose the usb cable groove that m...

  • Page 11

    © national instruments corporation 11 ni digital multimeters getting started guide using the usb dmm on a desktop note the plastic guides on the underside of the usb dmm allow stacking on top of other national instruments usb devices, such as the ni usb-5133high-speed digitizer. Do not apply the rub...

  • Page 12

    Ni digital multimeters getting started guide 12 ni.Com panel mounting the usb dmm to mount the usb dmm on a board or panel, complete the following steps while referring to figure 8. Figure 8. Mounting the usb dmm on a panel notes do not apply the rubber feet to the usb dmm when panel mounting. Apply...

  • Page 13

    © national instruments corporation 13 ni digital multimeters getting started guide installing a pcmcia dmm to install the pcmcia dmm, insert the pcmcia dmm into an available pcmcia slot as shown in figure 9. Figure 9. Pcmcia installation 6. Windows device recognition windows recognizes any newly ins...

  • Page 14

    Ni digital multimeters getting started guide 14 ni.Com 7. Configuring and testing in max to configure and test the dmm in max, complete the following steps: 1. Launch max (start»all programs»national instruments»measurement & automation). Max automatically detects the dmm you installed. 2. Expand de...

  • Page 15

    © national instruments corporation 15 ni digital multimeters getting started guide 4. Record the device number or device name assigned to the dmm. You need this when programming the dmm. • (ni-daqmx devices) the assigned device name is appended to the dmm in its configuration tree label. For example...

  • Page 16: 8. Connecting Signals

    Ni digital multimeters getting started guide 16 ni.Com 8. Connecting signals the following sections explain how to connect signals to the dmm front panel connectors for common measurements. For more information about these common measurements, refer to the ni digital multimeters help at start»all pr...

  • Page 17

    © national instruments corporation 17 ni digital multimeters getting started guide dc and ac current figure 12. Ni 4050 signal connections for current measurements note to measure current, the ni 4050 requires the ni csm-200ma or ni csm-10a current shunt module (shown in figure 12), which is availab...

  • Page 18

    Ni digital multimeters getting started guide 18 ni.Com 2-wire resistance figure 14. Ni 4050 signal connections for 2-wire resistance measurements figure 15. Ni 4060, ni 4065, and ni 407x signal connections for 2-wire resistance measurements 1 ni 4060 2 ni pxi/pci/pcie-4065 and ni 407x 3 ni usb-4065 ...

  • Page 19

    © national instruments corporation 19 ni digital multimeters getting started guide 4-wire resistance (ni 4060, ni 4065 and ni 407x only) 4-wire resistance measurements use both pairs of terminals. Use the configuration to measure low resistances accurately by eliminating the effects of lead resistan...

  • Page 20

    Ni digital multimeters getting started guide 20 ni.Com voltage drop across a diode the dmm can excite a device under test and read the resulting voltage drop, which is useful for testing diodes. Figure 18. Ni 4050 signal connections for diode measurements figure 19. Ni 4060, ni 4065, and ni 407x sig...

  • Page 21: 9. Programming The Dmm

    © national instruments corporation 21 ni digital multimeters getting started guide using cables and probes the dmm shipping kit contains a pair of test probes with safety banana plugs. These probes meet international safety requirements, including ul 3111 and iec 1010-1, for the full range of applic...

  • Page 22

    Ni digital multimeters getting started guide 22 ni.Com ni labview signalexpress limited edition ni-dmm 2.7 and later includes a stand-alone, evaluation version of ni labview signalexpress that allows you to quickly configure your ni hardware to acquire, generate or perform hardware comparison using ...

  • Page 23: Appendix A: Front Panels

    © national instruments corporation 23 ni digital multimeters getting started guide appendix a: front panels pxi/pci/pci express/usb the pxi, pci, pci express front panels have four shrouded banana plug connectors and one 9-pin connector. The usb front panel has five shrouded banana plug connectors a...

  • Page 24

    Ni digital multimeters getting started guide 24 ni.Com the banana plug connectors are high-voltage, safety signal connectors. The 9-pin connector labeled aux i/o is a digital signal connector, which carries ttl-level triggering signals for use with external scanning equipment. Refer to the ni digita...

  • Page 25

    © national instruments corporation 25 ni digital multimeters getting started guide appendix b: chassis recommendations and system considerations this appendix specifies the recommended chassis components and conditions for a system that includes national instruments dmms. Pxi chassis recommendations...

  • Page 26: Appendix C: Fuse Replacement

    Ni digital multimeters getting started guide 26 ni.Com additional recommendations for the ni pci-4070 the cooling capability of most industrial and personal computers is less than the cooling capability of a pxi chassis. The ni pci-4060 and the ni pci/pcie-4065 dissipate low enough power that additi...

  • Page 27

    © national instruments corporation 27 ni digital multimeters getting started guide ni 4060 to replace the fuse, complete the following steps. (ni pxi-4060) 1. Remove all front panel connections from the ni pxi-4060. 2. Power down the chassis, and remove the device. 3. View the device at the angle sh...

  • Page 28

    Ni digital multimeters getting started guide 28 ni.Com (ni pci-4060) 1. Remove all front panel connections from the ni pci-4060. 2. Power off the computer, and remove the device. 3. Remove the four screws that secure the top and bottom insulators onto the device, as shown in figure 23. Figure 23. Re...

  • Page 29

    © national instruments corporation 29 ni digital multimeters getting started guide 5. Locate the 5 × 20 mm glass fuse shown in figure 24. Figure 24. Removing the fuse from the ni pci-4060 6. Remove the fuse, and verify the fuse is blown by measuring discontinuity across the fuse using another meter....

  • Page 30

    Ni digital multimeters getting started guide 30 ni.Com ni 4065 1. Remove all front panel connections from the ni 4065. • (ni pxi/pci/pcie-4065) power down the chassis, and remove the device. • (ni usb-4065) disconnect the usb cable from the ni usb-4065. 2. Locate the fuse holder on the ni 4065. • (n...

  • Page 31

    © national instruments corporation 31 ni digital multimeters getting started guide figure 26. Locating the fuse on the ni pci/pcie-4065 figure 27. Locating the fuse on the ni usb-4065 1 fuse holder 1 fuse holder 1 1.

  • Page 32

    Ni digital multimeters getting started guide 32 ni.Com 3. Insert a screwdriver into the slot on the fuse holder. 4. Turn counterclockwise. 5. Pull out the holder, and remove the 5 × 20 mm glass fuse. 6. Verify the fuse is blown by measuring discontinuity across the fuse using another meter. 7. Inser...

  • Page 33

    © national instruments corporation 33 ni digital multimeters getting started guide 6. Locate the fuse slot shown in figure 29. Figure 29. Removing the fuse from the ni pxi-407x 7. Pry the fuse loose from the slot. 8. Verify the fuse is blown by measuring discontinuity across the fuse using another m...

  • Page 34

    Ni digital multimeters getting started guide 34 ni.Com (ni pci-4070) 1. Remove all front panel connections from the ni pci-4070. 2. Power down the chassis, and remove the device. 3. Hold the ni pci-4070 at the angle shown in figure 31, and locate the fuse holder. Figure 31. Locating the fuse on the ...

  • Page 35

    © national instruments corporation 35 ni digital multimeters getting started guide figure 32. Removing the fuse 4. Remove the old fuse. 5. Verify the fuse is blown by measuring discontinuity across the fuse using another meter. 6. Install the new fuse. 7. Push the fuse holder back into the housing a...

  • Page 36

    National instruments, ni, ni.Com, and labview are trademarks of national instruments corporation. Refer to the terms of use section on ni.Com/legal for more information about national instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their resp...

  • Page 37

    Initializ e ೋᦼൻ configure har d ware 䊊䊷䊄䉡䉢䉝䈱᭴ᚑ basic configur ation ၮᧄ᭴ᚑ adv anced configur ation ਄⚖᭴ᚑ read ⺒䉂ข䉍 initiate/fetc h 㐿ᆎ㪆䊐䉢䉾䉼 close session 䉶䉾䉲䊢䊮䈱 ⚳ੌ ni-dmm p rogramming flo w ίυΈρηϋΈέυȜ ni-dmm.