The Fault LED (red) illuminates when a fault occurs. A fault
disables the drive. Causes for a fault are the following:
•
Vsup undervoltage. Refer to the NI 9502 Module Faults
topic in the LabVIEW Help, available by selecting Help»
LabVIEW Help, for more information about this fault.
Caution
Vsup greater than 40 V will result in damage to
the NI 9502.
•
Vsup overvoltage
Caution
Current greater than ±8 A will result in damage
to the NI 9502.
•
Overcurrent
•
Module current sampling fault. Refer to the NI 9502 Module
Faults topic in the LabVIEW Help, available by selecting
Help»LabVIEW Help, for more information about this fault