National Instruments NI SCXI -1339 Installation Instructions Manual - Maximum Current

Summary of NI SCXI -1339

  • Page 1

    Installation instructions ni scxi -1339 terminal block for the ni scxi-1129 this guide describes how to install and connect signals to the national instruments scxi-1339 terminal block to configure the scxi-1129 switch module as a dual 4 × 32 matrix. Screw terminals on the scxi-1339 allow you to acc...

  • Page 2: 1. Unpack The Terminal Block

    Ni scxi-1339 installation instructions 2 ni.Com italic italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply. Monospace text in this font denotes text or characters t...

  • Page 3: 3. Connect Signals

    © national instruments corporation 3 ni scxi-1339 installation instructions ❑ long-nose pliers ❑ wire cutter ❑ wire insulation stripper 3. Connect signals to connect the signal(s) to the terminal block, refer to figures 1 and 2 while completing the following steps: caution this module is rated for m...

  • Page 4

    Ni scxi-1339 installation instructions 4 ni.Com figure 1. Scxi-1339 top cover diagram 1 top cover 2 top cover screw 1 2.

  • Page 5

    © national instruments corporation 5 ni scxi-1339 installation instructions figure 2. Scxi-1339 parts locator diagram 4. Install the terminal block to connect the scxi-1339 to the scxi-1129 front panel, refer to figure 3 and complete the following steps: note install the scxi-1129 if you have not al...

  • Page 6: Specifications

    Ni scxi-1339 installation instructions 6 ni.Com figure 3. Installing the scxi-1339 terminal block specifications maximum working voltage maximum working voltage refers to the signal voltage plus the common-mode voltage. Channel-to-earth .....................................150 v, installation catego...

  • Page 7: Maximum Current

    © national instruments corporation 7 ni scxi-1339 installation instructions maximum current maximum current (per channel) .......................................... 2 adc, 2 aac environmental operating temperature............................ 0 to 50 °c storage temperature ..............................

  • Page 8: Ce Compliance

    National instruments, ni, ni.Com, and labview are trademarks of national instruments corporation. Refer to the terms of use section on ni.Com/legal for more information about national instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their resp...