National Instruments RMX-4120 User Manual - page 77
2-46
|
ni.com
Chapter 2
Basic Functions
CF12
1
Output-on startup state parameter
CV (CV is prioritized)
CF13
Detection time of OCP activation
0 ms
CF14
1
Current setting limit
ON (the setting is limited)
CF15
1
Voltage setting limit
ON (the setting is limited)
CF16
Panel display brightness setting
7
CF17
Communication monitor timer setting
OFF (Communication monitoring timer off)
CF18
Unused
—
CF19
3
Display setting on slave units for
master-slave parallel operation
OFF (not displayed on slave units)
CF20
LAN interface parameter
LAN (the LAN interface will be used)
CF21
Command language parameter
SCPI
CF22
Emulation parameter during remote
control
NONE (RMX programmable power supply
commands)
CF23
SCPI communication error display
parameter
OFF (not displayed)
CF24
Multichannel (VMCB) domain number
0 (the multichannel function is not used)
CF25
Multichannel (VMCB) channel number
0 (the RMX
programmable power supply
is
used as a master unit on the multichannel
network)
CF41
IP address assignment method
DHCP: ON
AUTO IP: ON
MANUAL IP: OFF
CF47
SCPI-RAW protocol TCP port number
5025
CF52
RS232C baud rate parameter
19.2 (kbit/s)
1
You can only specify this parameter when the RMX programmable power supply is being used as a master unit.
2
0 to 0.5 V or shorted.
3
You can only specify this parameter when the RMX programmable power supply is being used as a slave unit.
Table 2-10.
CONFIG Settings (Continued)
Parameter
Number
CONFIG Parameter
Parameter Description