National Railway Supply ERB-C 12/201 Installation, Operation And Service Instructions

Manual is about: Shelf-Mount Solid State Chargers

Summary of ERB-C 12/201

  • Page 1

    Www.Nationalrailwaysupply.Com 1 01434j national railway supply installation, operation and service instructions for erb-c shelf-mount solid state chargers erb-c models 12/201, 12/501 & 24/301 battery chargers please save these important safety and operating instructions for correct operation of the ...

  • Page 2

    Www.Nationalrailwaysupply.Com 2 01434j programmable options to personalize the charge profile. The charger can be programmed to charge batteries within a cell range of: 1 to 8 cells (models 12/201 and 12/501), or 1 to 18 cells (model 24/301) for gel cell, liquid lead-acid, and valve-regulated batter...

  • Page 3

    Www.Nationalrailwaysupply.Com 3 01434j warning: improper jumper connection may cause severe damage to the charger and the battery. Configure the jumpers for your ac voltage source (refer to the jumper diagram below). Place the ac and grounding ring terminals on the binding posts and tighten the post...

  • Page 4

    Www.Nationalrailwaysupply.Com 4 01434j adhesion, the battery surface must be cleaned with isopropyl alcohol. Ideal application temperature range is between 70 and 100 °f. Initial application to surfaces at temperatures below 50 °f is not recommended. Under cold conditions, the surface should be warm...

  • Page 5

    Www.Nationalrailwaysupply.Com 5 01434j up or down buttons. Holding the up or down buttons will also advance through the functions. Press enter. Response: the function will be executed and continue to display the function number or the display will show the present value in a programmable function. (...

  • Page 6

    Www.Nationalrailwaysupply.Com 6 01434j 12 error codes this function gives numbers that represent problems that have occurred with the charger. If a printer is connected to the charger, error messages will be printed. For a detailed explanation of the error messages, refer to item 10. The error codes...

  • Page 7

    Www.Nationalrailwaysupply.Com 7 01434j 25 "-40.0" minimum compensation temperature this function limits the temperature compensation at the value set so that the charger output voltage no longer changes at any temperature lower than the set value. This function has to be set along with the temperatu...

  • Page 8

    Www.Nationalrailwaysupply.Com 8 01434j 11. Printer option warning: the printer output is not isolated from the battery. The printer must be isolated from ground and from the battery terminals. Use an ac grounding adapter, number gcl3-749. With the rs-232 cable option, a printer can be connected to t...

  • Page 9

    Www.Nationalrailwaysupply.Com 9 01434j voltage per cell, 1.00 to 3.00 volts enter: 100 to 300 number of cells, 1 to 12 cells (models 12/201 and 12/501) enter: 1 to 12 for lead-acid batteries, use 1 to 8 number of cells, 1 to 24 cells (model 24/301) enter: 1 to 24 for lead-acid batteries, use 7 to 15...

  • Page 10

    Www.Nationalrailwaysupply.Com 10 01434j 16. Charger specifications model erb-c 12/201 erb-c 12/501 erb-c 24/301 ac input voltage 115vac (100-128) or 230vac (200-256) ac input current (full power) 115vac 5.2 amps 14.6 amps 16.5 amps 230vac 2.6 amps 7.8 amps 8.25 amps ac input frequency 60 – 100 + 5% ...

  • Page 11

    Www.Nationalrailwaysupply.Com 11 01434j 17. Parts list the following is a list of all the parts found in the national railway supply battery chargers. When replacing a part, use only original factory replacement parts of the correct size and rating. Erb-c models description 12/201 12/501 24/301 tran...

  • Page 12

    Www.Nationalrailwaysupply.Com 12 01434j 18. Wiring diagram.