National Vacuum Equipment 607 challenger series Owner's Manual And Operating Instructions - System Requirements
10
| 607 Challenger
Series
www.natvac.com | 800.253.5500
System Requirements
High Quality Components
•The 607 Challenger is a high performance vacuum pump and
requires compatible, high quality components as manufactured by
NVE
Shutoffs
•We recommend an 8” cage and a 6” S S ball which is standard in
all of our primary and secondary shutoffs
Hose
•Use 3” or larger hose to plumb your system We recommend you
use a hose that can withstand high temperatures such as hot tar-
asphalt hose
Pressure and Vacuum Relief Valves
•A properly adjusted pressure relief and vacuum relief valves should
also be incorporated in the system between the secondary shutoff
and the pump
•The relief valves should be set to where the pump operates at a
maximum temperature of 375 degrees Fahrenheit
1. Remove the protection cap “A”
2. Turn the spring-tighter “B”, through a spanner “C”,
Clockwise to increase the pressure, Anti-clockwise
to reduce the pressure
3. Once obtained the desired pressure, screw down the lock nut “D”
4. Screw down the protection cap and fix it using the rings “E” situated
on the valve body and on the cap
1
2
3
Picture 1. 1. Unscrew the lock nut “A”
2. Turn the spring-tightener “B”
Picture 2. Once obtained the desired pressure, screw down the lock nut “A”
Picture 3. Fix the setting, using the rings “C” Situated on the body and on the spring tightener
Pressure and Vacuum
Relief Valve Setting
Instructions
Vacuum Relief Valve
Pressure Relief Valve