NCR 7460 Manual - Preface

Other manuals for 7460: User Manual
Manual is about: Retail Terminal

Summary of 7460

  • Page 1

    Ncr 7460 retail terminal release 1.1 site preparation 18 b005-0000-1281 issue b.

  • Page 2

    The products described in this book are licensed products of ncr corporation. Ncr is a registered trademark of ncr corporation. Pentium is a registered trademark of intel corporation. It is the policy of ncr corporation (ncr) to improve products as new technology, components, software, and firmware ...

  • Page 3: Preface

    Preface this is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully. It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with ncr specification...

  • Page 4: About This Book

    2 about this book this book provides site preparation information for terminal components. Peripheral component and ac wiring site preparation information is not provided in this book. The associated reference documents are listed in the “related site preparation data” section. This book contains th...

  • Page 5

    3 no comment, suggestion, or advice offered or not offered about preparation of the site, nor any inspection of the site, whether before of after preparation, is to be taken as approval of the location of the site and equipment or its preparation. Ncr will not be liable in respect to any comment, su...

  • Page 6: References

    4 references • ncr 7460retail terminal hardware user’s guide (b005-0000-1280) • ncr fitclient software user's guide (b005-0000-1235) • ncr 7460 retail terminal parts identification manual (b005-0000-1282) • ncr 7460retail terminal hardware service guide (b005-0000-1338).

  • Page 7: Table Of Contents

    5 table of contents introduction 1 interpreting the model number (example) .................. 2 related site preparation data......................................... 3 how to order................................................................... 4 customer responsibilities ..........................

  • Page 8: Revision Record

    6 cable routing considerations 20 mounting consideration 21 mounting considerations 22 wall mounting the 7460 23 wall mounting the complete unit .............................. 24 wall mounting the lcd operator display only........ 25 7460 system cables ..................................................

  • Page 9

    7 radio frequency interference statements federal communications commission (fcc) information to user this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of fcc rules. These limits are designed to provide reasonable protection against ...

  • Page 10: Declaration Of Conformity

    8 declaration of conformity manufacturer's name ncr corporation manufacturer's address ncr corporation retail solutions division— atlanta 2651 satellite boulevard duluth, ga 30096-5810 type of equipment information technology equipment model number class 7460 electrical ratings (input) 100-120 v/200...

  • Page 11: Introduction

    1 introduction 18443 this document provides the information necessary to prepare a site to ncr specifications prior to installing a terminal. The site must be properly prepared before the terminal is installed because site preparation deficiencies may be difficult to detect and correct after install...

  • Page 12

    2 interpreting the model number (example) 18042 language 01 = international english power required 80 = 110 -240 vac 50/60 hz ncr model 74xx 20 1 x 80 operating system 2 = windows (nt, 98) industry 0 = 1 = self service 2 = processor 21 = pentium w/ 12.1" lcd std. 31 = pentium w/ 12.1" lcd scan 22 = ...

  • Page 13

    3 related site preparation data ac power and communications wiring title order number ncr ethernet communications wiring guide bst0-2118-82 ncr terminal ac power wiring guidelines bst0-2115-53.

  • Page 14: How To Order

    4 how to order information products are available through several different channels. You need an order form if you are using fax, e-mail, or mail order. Order forms are available to ncr personnel through quicklook. In quicklook, click on forms & templates , then select information products order fo...

  • Page 15: Customer Responsibilities

    5 customer responsibilities before the system can be installed, the customer must do or provide the following: • when required by ncr, provide the ncr customer services representative with appropriate drawings that indicate: − location of the equipment − site wiring (power and communications, paths ...

  • Page 16: Lan Communications

    6 ac store wiring requirements the customer must provide suitable ac power for the web kiosks, associated equipment, and devices. A dedicated unswitched power line dedicated to the ncr equipment installation is recommended. Refer to the workstation and peripherals ac wiring guide (bsto- 2115-53) for...

  • Page 17

    7 system configuration diagram 19154 lan ethernet 7460 retail terminal 5992 signature capture rs-232 peripherals 5945 electronic payment terminal transaction printers parallel/ serial ps/2 kbd 7158 7194 7892 bi-modal presentation scanner 2189 dvi cash drawer rs-232 keyboard 5972/5973 customer displa...

  • Page 18: Physical Considerations

    8 physical considerations this section presents the following information: • operating and service clearance requirements • display mounting considerations • component weights • airflow requirements • power requirements.

  • Page 19: Ncr 7460 Dimensions

    9 ncr 7460 dimensions 18494 292 mm (12 in.) 324 mm (12.75 in.) 324 mm (12.75 in.) 368 mm (14.50 in.) 343 mm (13.50 in.) 134 mm (5.25 in.) 203 mm (8 in.).

  • Page 20

    10 7453-k005 cash drawer 18038 455.6 mm ( 17.94in.) 108 mm (4.25 in.) 450.9 mm (17.75 in.) 263.5 mm (10.375 in.) operating and service clearance for drawer ncr 2189 cash drawer 16676 133 mm (5.25 in.) 330 mm (13 in.) (18.25 in.) operating and service clearance for drawer 464 mm 527 mm (20.5 in.).

  • Page 21

    11 ncr 2113 cash drawer 17310 96 mm (3.75 in.) 400 mm (15.75 in.) 450 mm (17.75 in.) 254 mm (10 in.) operating and service clearance for drawer ncr 7194 thermal receipt printer 16492 130 mm (5.10 in.) 157 mm (6.20 in.) 85 mm (3.30 in.) 212 mm (8.3 in.) 187 mm (7.4 in.).

  • Page 22

    12 ncr 7158 thermal receipt/impact printer 165 mm (6.50 in.) 336 mm (13.25 in) 229 mm (9.00 in) 305 mm (12.00 in.) 17307 ncr 7196 thermal receipt printer 108 mm (4.25 in.) 140 m (5.50 in.) 146 mm (5.75 in.) 254 mm (10.00 in.) 17306.

  • Page 23

    13 ncr 5972-1000 2x20 remote customer display 262 mm (10.3 in.) 15708 95 mm (3.75 in.) 506 mm (22.1 in.) 30 mm (1.2 in.) 95 mm (3.75 in.) 119 mm (4.7 in.).

  • Page 24

    14 integrated 5973 international vfd customer display 350 mm (13.8 in.) 45 mm (1.8 in.) 95 mm (3.75 in.) 95 mm (3.75 in.) 110 mm (4.3 in.) 262 mm (10.3 in.) 17236a.

  • Page 25

    15 ncr 2336-k007 external cd-rom drive 23 mm (0.9 in.) 155 mm (6.1 in.) 218 mm (8.6 in.) 16951 note: allow 75 mm (3 in.) clearance in the back of the ncr 2336-k007 external cd-rom drive for connector and cable clearance..

  • Page 26: Component Weights

    16 component weights the following table shows the component weights for each integrated component. Retail terminal components weight kg. Lbs. 7460 terminal 7.3 16.1 7460 lcd (operator display only) 2.9 6.4 7460 base unit (no lcd operator display) 4.6 10.1 2189/2113 cash drawer 9.5 20.9 7453-k005 ca...

  • Page 27: Ventilation Clearance

    17 ventilation clearance leave the minimum clearances shown below for proper cooling conditions for the terminal. Ncr 7460 18494d 76 mm (3 in.) 25 mm (1 in.) minimum vertical clearance minimum horizontal clearance.

  • Page 28: Power Requirements

    18 power requirements base module contain a three-wire, single-phase, selectable 120/240 volt ac, 120 watt power supply. The following tables show operating specifications for the power supply. Maximum input power specifications 120 volt 240 volt voltage ranges 90 - 136 vac 198 - 257 vac frequency 5...

  • Page 29

    19 item description 3.3 vdc 5.0 vdc 12 vdc external power source required keyboards 0.30 display 2x20 vfd powered from serial port 0.50 display 2x20 lcd powered from serial port (+12v to +5v conversion in cable) 0.10 5992 signature capture device 0.80 5945 electronic payment device 0.50 7892 present...

  • Page 30

    20 cable routing considerations external cables are routed through the bottom of the unit behind the msr. 1. Remove the msr by elevating the unit and pulling down and out on the msr housing as illustrated below: 2. Route cable and return msr to the as found position. 18474 pull down and out msr typi...

  • Page 31: Mounting Consideration

    21 mounting consideration a tilt mount terminal can be installed on a flat horizontal surface or a flat vertical surface. 18443 shown below is the base unit option without the operator lcd. The lcd mount access cover snaps off and on. 18831 lcd mount access cover.

  • Page 32: Mounting Considerations

    22 mounting considerations tilt mount terminal can be installed on a flat horizontal surface or a flat vertical surface. 18443.

  • Page 33: Wall Mounting The 7460

    23 wall mounting the 7460 the 7460 unit or the operator display can be installed on a flat vertical surface. 18835 7460 wall mount operator display mount.

  • Page 34

    24 wall mounting the complete unit to install a wall mount on a flat vertical surface, use the 7460-k533 wall mount bracket kit . 1. Secure the wall plate to the wall with lag screws (4) into the studs or with hardware of similar strength. The recommended viewing height for the terminal is 1.2 m (48...

  • Page 35

    25 wall mounting the lcd operator display only to flush mount the operators display on a flat vertical surface, use the k502 flush mount bracket kit . 18832 flush mount flush mount w/lcd cable penetration through wall.

  • Page 36

    26 1. Secure the wall plate to the wall with lag screws (4) into the studs or with hardware of similar strength. The recommended viewing height for the terminal is 1.2 m (48") from the floor to the center of the screen. Note: if routing cable through the wall drill a hole in the wall for the cable. ...

  • Page 37: 7460 System Cables

    27 7460 system cables corporate id part number description 1416-c372-0006 497-0409394 dual cash drawer (y cable) 1416-c266-0040 497-0407943 9 pin female to 9 pin female rs-232 1416-c266-0152 497-0409379 7193 rs-232 50' 9 pin female to 9 pin female 1416-c337-0010 497-0407427 rs-232 interface, integra...

  • Page 38: Environmental Requirements

    28 environmental requirements barometric pressure the 7460 retail terminal is designed to operate within the following barometric pressure conditions: • maximum operating altitude: 3000 m (9843 ft) • operating range of pressure: 105 kpa to 69 kpa (15.2 lb./in. To 10.0 lb./in.) temperature the 7460 r...

  • Page 39

    Appendix a: transient protection ac power line transient protection in the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced onto power lines. Such transient energy ca...

  • Page 40

    A-2 appendix a: transient protection • be listed by the accepted safety organization for the country involved (ul, csa, vde, etl, and so on) and the installation must conform to local, state, and national electrical codes and regulations. Data line transient protection the nature of the transient ph...

  • Page 41: Index

    Index —5— 5973 international vfd customer display, 14 —c— cable routing considerations, 20 cd-rom drive, 15 communications, 6 configuration diagram, 7 customer display, 14 customer responsibilities, 5 —d— dimensions, 9 dimensions and weight weight, 16 —e— environmental requirements, 28 barometric pr...

  • Page 42

    7196 thermal receipt printer, 12 —t— temperature, 28 —v— ventilation clearance, 17 —w— weight, 16 wiring requirements, 6.

  • Page 44

    B005-0000-1281 june 2001 printed on recycled paper.