North Star 13000 PTOG Owner's Manual

Manual is about: Power Take-Off Generator

Summary of 13000 PTOG

  • Page 1

    P r o v e n p e r f o r m a n c e model 13000 ptog item # 165929 power take-off generator m165929a owner’s manual 13000 ptog any questions, comments, or problems? Call customer service at 1-800-270-0810 hours: m onday - friday 7:30 am to 5:30 pm saturday 7:30 to 11:30 am cst 00293.

  • Page 2: Thank You

    1 thank you thank you for purchasing a northstar power take-off generator. Your machine is designed for long life, dependability, and the top performance you demand. Please take time now to read through this manual so you can better understand the machine’s operation, maintenance and safety precauti...

  • Page 3: Specifications

    2 specifications item number #165929 maximum output 13000 watts (w) continuous output 12000 watts (w) voltage 120 / 240 volt (v) phase single phase (4-wire) frequency 59.0-63.0 hertz (hz) power factor 100 % minimum pto hp 24 hp at 540 rpm input shaft 1 3/8” diameter, 6 spline 120v receptacle (2) 20 ...

  • Page 4

    3 machine component identification ref. Description ref. Description 1 50a circuit breakers 10 120/240v 50a receptacle 2 30a circuit breaker 11 shield 3 20a circuit breakers 12 gear box 4 warning decals 13 grounding screw 5 1 3/8”, 6 spline input shaft 14 mounting holes 6 oil drain plug 15 fan vents...

  • Page 5

    4 generator features references 1-3 circuit breakers. • reference 1 - two 50a push-to-reset circuit breakers. • reference 2 - one 30a push-to-reset circuit breaker. • reference 3 - two 20a push-to-reset circuit breakers. References 4 - warning decals. Read and follow all warnings. References 5 - 1 3...

  • Page 6

    5 reference 17 - breather/oil fill plug. Use sae 90 gear oil. Maintain the correct oil level. Over filling can cause the oil to over heat and damage seals and bearings. The gear box is shipped with temperary plastic plug, remove and replace with the metal breather plug that is in the manual bag. Int...

  • Page 7

    6 choose a location where the generator will not be exposed to rain, snow or direct sunlight. Common places for mounting your pto generator are to a trailer or a cement slab. However you choose to mount the generator, make sure it can get as close to the load as possible. This will make using the ge...

  • Page 8

    7 load application it is important to determine the total electrical load before it is connected to the generator. The two major factors in determining the life of a generator head are: heat build up, caused by overloading the generator and corrosive contaminants, that attack the wiring insulation. ...

  • Page 9

    8 as the electric motor windings. Because the heavy surge of current is required for only an instant, the generator will not be damaged if it can bring the motor up to speed in a few seconds. If difficulties in starting a motor are experienced, turn off all other electrical loads and if possible red...

  • Page 10

    9 grounding - all units must be grounded. Drive a 3/4” or 1” copper pipe or rod into the ground close to the generator. The pipe/rod must penetrate moist earth. Connect an approved ground clamp to the pipe. Run a 8 gauge wire from the clamp to the generator ground screw. Do not connect to a water pi...

  • Page 11: Troubleshooting

    10 troubleshooting problem possible causes possible remedies voltage too low. A) engine speed too slow. B) generator is overloaded. A) increase tractor rpms. B) reduce the load. (see load application section of this manual.) circuit breaker trips. A) defective load connected to generator. B) defecti...