    Diesel engine exhaust and some of its constitu- ents are known to the state of california to cause cancer, birth defects, and other reproductive harm. — california — proposition 65 warning: northern lights 4420 14th avenue n.W. Seattle, wa 98107 tel: (206) 789-3880 fax: (206) 782-5455 copyright © 20...

  • Page 3

    Im1000 01/13 1 proprietary information this publication is the sole property of northern lights, inc. It may not be reproduced in whole or part without the expressed written permission of northern lights, inc. © northern lights, inc. 2008. All rights reserved. Litho u.S.A. Publication number: im1000...

  • Page 4

    Im1000 02/13 2.

  • Page 5

    Im1000 02/13 introduction this manual will explain installation procedures for northern lights marine generator sets. The instructions are general in nature and intended to be used only as guidelines. If you have questions, please contact your local dealer or factory offi ce. The installation of a m...

  • Page 6

    Im1000 02/13 4.

  • Page 7

    Im1000 02/13 l, m, nl 673 d, t, a, l, w, h l -northern lights propulsion engine (lugger) m - northern lights marine generator set nl - northern lights industrial generator set model number of base engine block d = naturally aspirated t = turbocharged a = aftercooled & turbo l = long stroke w = auxil...

  • Page 8

    Im1000 02/13 • turn the coolant tank cap slowly to relieve pressure before removing. Add coolant only when the engine is stopped and cool. • mount fi re extinguisher near engine. • always disconnect the battery ground strap before making adjustments. • operate engine in properly ventilated areas. • ...

  • Page 9

    Im1000 02/13 electric motors and appliances containing electric motors usually require up to ten times the running wattage during starting. A good rule of thumb when working with motor loads is to take the running wattage of the largest motor and multiply that by ten. Then add the running wattage of...

  • Page 10

    Im1000 02/13 the two main elements that decide where a generator should be located are 1 the availability of space, and 2 the adequacy of structural support. Thought should be given to ventilation, cooling and exhaust systems as well, and these areas will be covered later. The generator is usually l...

  • Page 11

    Im1000 02/13 figure 2: exhaust manifold above load water line figure 4: exhaust manifold below load water line figure 3: exhaust manifold at load water line exhaust system 9.

  • Page 12

    Im1000 02/13 exhaust system general there are two basic types of exhaust systems used in marine generator set installations: a) wet exhaust - the exhaust gases are cooled by the addition of water from the engine cooling system at some point along the exhaust system. The exact point at which the wate...

  • Page 13

    Im1000 02/13 failing to follow these instructions when installing a certifi ed engine in a vessel violates federal law (40 cfr 1068.105(b)), subject to fi nes or other penalties as described in the clean air act. If the exhaust manifold is signifi cantly below the water line, causing a rise of great...

  • Page 14

    Im1000 02/13 figure 5:keel cooling keel cooling or skin cooling keel cooling or skin cooling is a closed circuit method of cooling that uses only fresh water. Engine heat is dissipated by passing coolant through tubes fi tted to the outside of the hull (keel cooling), or incorporated as part of the ...

  • Page 15

    Im1000 02/13 extreme care is required in the design and installation of fuel systems. Fuel leakage presents a fi re and explosion hazard. Follow u.S.C.G. Codes and use only components that are specifi ed for marine applications. Each northern lights generator has a fuel manifold with connections for...

  • Page 16

    Im1000 02/13 noise control in a boat, noise is transmitted two ways, through the air or through the hull. Proper installation can control noise from both sources. Northern lights generators have rubber isolation mounts which connect the unit to a rigid base frame. The frame contains an integral drip...

  • Page 17

    Im1000 02/13 northern lights generators utilize negative ground electrical systems. The negative (-) terminal of the battery should be connected to the cap screw on the bell housing near the starter. In the case of a “fl oat- ing ground”, however, do not connect the negative (-) terminal to the engi...