Northern Stoker 30-30 Owner's Manual - Maintenance Schedule
15
DAILY (DURING THE HEATING SEASON):
ROUTINE
LOCATION IN THE MANUAL/ACTION
Each morning, restart or refuel the fire in the Northern
Stoker. Turn OFF combustion chamber blower fan when
refueling! Once refueled, turn ON combustion chamber
blower fan (Toggle Switch on upper right corner of structure).
Press the “START” button (C) on Electronic Control
System.
Pages 6 , 7
Turn OFF combustion chamber blower fan when
refueling!
Clear any flammable debris 8’ (2438 mm) around the front,
back and sides.
Page 2
Visually check that the Circulator Pump is functioning
Page 4
WEEKLY (DURING THE HEATING SEASON):
ROUTINE
LOCATION IN THE MANUAL/ACTION
Ash removal and clean out augers.
Page 9
Observe light layer of soot, fly ash or creosote on the
combustion chamber walls, chimney flue, chimney connector
or chimney and remove.
Page 9
Top up with water to ensure there is not an air lock.
Page 4
MONTHLY (DURING THE HEATING SEASON):
ROUTINE
LOCATION IN THE MANUAL/ACTION
Inspect and top up the system water level. Check for any
leakage around fittings.
Page 4
ANNUALLY (USUALLY SPRING SHUTDOWN):
ROUTINE
LOCATION IN MANUAL/ACTION
Place a chimney cap over the chimney to keep rain out,
inspect silicone caulking, door hardware and gaskets.
N/A
IMPORTANT! This maintenance schedule is recommended however, depending on the
usage, seasonal climate and fuels used, you the owner may need to step up the frequency of
the routines listed here to ensure a properly functioning Northern Stoker.