  • Page 1

    Standard duty double lever arm application for frame reveals to 6-7/8” (175mm) stop (push) side of door installation for handed (not reversible) units door openings 85° to 110° use series 6920 / 6921 door openings 111° to 180° use series 6930 / 6931 80-9369-0120-020 (09-08 ) right hand door left han...

  • Page 2

    80-9369-0120-020 (09-08) • u.L. Labeled fire or smoke barrier door assemblies require that the 120vac (60hz) power input to the powermatic™ door operator be supplied through normally closed alarm contacts of the alarm system/alarm panel. • power input to powermatic door operator must be 120 vac (60h...

  • Page 3

    80-9369-0120-020 (09-08) general fasteners for frame hollow metal door frame reinforcing frame material 12 ga. .1046 14 ga. .0747 16 ga. .0598 18 ga. .0478 (2.66) (1.90) (1.52) (1.21) recommended 12 ga. .1046 10 ga. .1343 10 ga. .1343 8 ga. .1644 (2.66) (3.41) (3.41) (4.18) min. Required 18 ga. .047...

  • Page 4

    80-9369-0120-020 (09-08) • determine hand of door from illustration on page 3. • using template, locate and prepare holes in the frame and door: – 7/8" (22mm) diameter holes for conduit, for power input and for switch/sensor wires. On new construction these holes will generally be drilled by the fra...

  • Page 5

    80-9369-0120-020 (09-08) activation mode – (push and go) functions – power operator / power assist: • rotate the “sc” valve counter-clockwise to adjus opening speed (por) or opening force (pas). • rotate the “pa”valve clockwise if needed to adj st pressure. (see illustrations on page 2 for dip switc...

  • Page 6

    80-9369-0120-020 (09-08) general product information (see illustrations on page 2 for location of switch and valves.) function and operation sequence • selector mode switch • "sc" speed control valve • "pa" pressure adjustment valve – this is a three (3) position switch that has positions marked "of...

  • Page 7

    80-9369-0120-020 (09-08) 7 pas dn t2 t1 pinion timing pulley screw els board pulley led timing belt pinion timing pulley cw ccw els board timing instructions: **note: if led should turn off during the above procedure without any significant movement of els board pulley, this is not a problem. The ti...

  • Page 8

    80-9369-0120-020 (09-08) 8 troubleshooting because of the sophisticated nature of the powermatic product, there are a number of steps during the installation procedure that if overlooked or misapplied, can create incorrect functioning or a complete failure of operation. • door closing force is insuf...