Nothern Industrial Tools 102181 Owner's Manual - page 5
Page: 5 of 8
OPERATION
Set Up
Fig. 1
1. You will need to prepare a 1/4" air connector (sold separately) to connect to the Air Inlet.
First, wrap the 1/4" air connector (not included) with pipe thread seal tape before
connecting to an Air Source Hose (not included).
2. Attach air hose to the Air Inlet on the Oscillating Sander. Note: If you are not using an
automatic oiler system, before operation, add a few drops of Pneumatic Air sander Oil to
the airline connection. Add a few drops more after each hour of continual use.
3. Set the air pressure on your compressor to 90 PSI. Do not exceed the recommended air
pressure of 90 PSI.
4. Check the air connection for leaks.
MAINTENANCE
WARNING:
Make sure the air sander is disconnected from its power source before
attempting any maintenance, cleaning, or inspection.
•
Maintain your air sander.
It is recommended that the general condition of any air sander be
examined before it is used. Keep your air sander in good repair by adopting a program of
conscientious repair and maintenance in accordance with the recommended procedures found
in this manual. If any abnormal vibrations or noise occurs, turn the air sander off immediately
and have the problem corrected before further use. Have necessary repairs made by qualified
service personnel.
•
Cleaning.
Use only soap and a damp cloth to clean your air sanders. Many household cleaners
are harmful to plastics and other insulation. Never let liquid get inside a air sander.