Notifier AFP1010 Manual

Other manuals for AFP1010: User Manual
Manual is about: Fire Alarm Control Panel

Summary of AFP1010

  • Page 1

    Document 50182 07/31/97 revision: a p/n 50182:a3 ecn 96-424 for the notifier am2020/afp1010 and afp-200 fire alarm control panels the lcd-80tm liquid crystal display 12 clintonville road northford, ct 06472 203-484-7161 fax: 203-484-7118 www.Pdf-zoo.Com.

  • Page 2

    Warning: this equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for class a computing device pursuant to sub...

  • Page 3: Table of Contents

    3 document 50182 rev a2 10/28/96 p/n 50182:a2 table of contents section one: lcd-80tm features ..................................................... 4 section two: operating the lcd-80tm ............................................. 6 display patterns ...................................................

  • Page 4

    Document 50182 rev a2 10/28/96 p/n 50182:a2 4 section one: lcd-80tm features the lcd-80tm alphanumeric display module is an ancillary display and control device that may be used with the am2020/afp1010 and afp-200 fire alarm control panels. • 80-character lcd display (backlit under normal & alarm co...

  • Page 5

    5 document 50182 rev a2 10/28/96 p/n 50182:a2 the lcd-80tm operates like a crt terminal without full keyboard capability, but with the advantages of 24 vdc power, wall mount, and multiple terminal location with acknowledge, signal silence and reset. The lcd-80tm has full point-display capacity and r...

  • Page 6

    Document 50182 rev a2 10/28/96 p/n 50182:a2 6 section two: operating the lcd-80tm display patterns the lcd-80tm displays directly the information from the afp-200 or am2020/afp1010 terminal interface without alteration. Note: the alarms pending, troubles pending, alarm count and trouble count inform...

  • Page 7

    7 document 50182 rev a2 10/28/96 p/n 50182:a2 section three: lcd-80tm electrical connections to next lcd-80tm from eia-485 source (refer to table below) lcd-80tm refer to appendix a for shield termination instructions. Important: the lcd-80tm requires the connection of 24 vdc power in addition to th...

  • Page 8

    Document 50182 rev a2 10/28/96 p/n 50182:a2 8 the lcd-80tm can be powered by an mps-24a main power supply or by the afp-200 power supply. The power run to the lcd-80tm must be power-limited but need not contain a power supervision relay since loss of power is inher- ently supervised through loss of ...

  • Page 9

    9 document 50182 rev a2 10/28/96 p/n 50182:a2 appendix a: eia-485 shield terminations the eia-485 circuit must be wired using a twisted-shielded pair cable having a characteristic impedance of 120 ohms, +/- 20%. Do not run cable adjacent to; or in the same conduit as; 120-volt ac service, noisy elec...

  • Page 10: Notes

    Document 50182 rev a2 10/28/96 p/n 50182:a2 10 notes www.Pdf-zoo.Com.

  • Page 11: Notes

    11 document 50182 rev a2 10/28/96 p/n 50182:a2 notes www.Pdf-zoo.Com.

  • Page 12: Limited Warranty

    Notifier ® warrants its products to be free from defects in materials and workmanship for eighteen (18) months from the date of manufacture, under normal use and service. Products are date stamped at time of manufacture. The sole and exclusive obligation of notifier ® is to repair or replace, at its...