Novar NOVAR-1xxx NRC Operating Manual

Manual is about: Power Factor Controller and Remote Controller

Summary of NOVAR-1xxx NRC

  • Page 1

    Kmb systems, s.R.O. Dr. M. Horákové 559, 460 06 liberec 7, czech republic tel. +420 485 130 314, fax +420 482 736 896 email : kmb@kmb.Cz , internet : www.Kmb.Cz 10/2013 remote controlled target pf and remote controlled outputs compensation systems based on novar line power factor controllers novar-1...

  • Page 2: List Of Contents

    Novar-nrc kmb systems 2 list of contents 1. Application.................................................................. 4 1.1 remote controlled target power factor compensation systems ..................................................4 1.2 remote controlled outputs compensation systems .............

  • Page 3

    Novar-nrc kmb systems 3 3.3.6 parameter 20 – alarm status.......................................................................................................17 3.3.7 parameter 21 – instrument failure status ...................................................................................17 3.3....

  • Page 4: 1.  Application

    Novar-nrc kmb systems 4 1. Application 1.1 remote controlled target power factor compensation systems when connecting major sources to medium voltage network, a remote control of reactive power is often required. One possibility is to control target power factor using pulse signals from distributor ...

  • Page 5

    Novar-nrc kmb systems 5 detailed description of the novar power factor controllers can be found on the manufacturers website at www.Kmbsystems.Eu ..

  • Page 6: Controllers

    Novar-nrc kmb systems 6 2. The „novar1xxx nrc“ special version power factor controllers the „nrc“ special version is available for following novar power factor controller (pfc) models : 1106, 1114, 1206, 1214 ( marking example : novar1214 nrc). The 1414 and 1312 models can be delivered with limited ...

  • Page 7

    Novar-nrc kmb systems 7 tab. 2.1 : novar-1xxx nrc additional and affected parameters # name range step default comment 1 (7) target pf for metering rate 1 (2) actual remote controlled target pf 0.80 l ÷ 0.80 c „ex.Xx“ format indicates remote controlled target pf value in the „rcc“-mode 0.01 0.98 l i...

  • Page 8

    Novar-nrc kmb systems 8 2.1.2 remote controlled outputs – the „i/o“ mode the novar1xxx nrc pfc is connected to the nrc86 remote controller (optionally to more of such controllers) through a rs-485 communication link. Capacitor (or choke) contactors are not connected to the pfc outputs but to corresp...

  • Page 9

    Novar-nrc kmb systems 9 if the metering rate 2 control is enabled and any of the rcc-modes is set simultaneously, the target pf is remote controlled by external nrc86 unit only when the metering rate 2 (tariff 2) just active.In such case, the actual value of remote controlled pf with preceding „e“ c...

  • Page 10

    Novar-nrc kmb systems 10 note 1 : the fifteen-minute average value of the active current iact is not displayed, you can check the actual value of the active current iact only. So you must take in mind appriopriate delay in the alarm activation and deactivation when checking its behaviour. Note 2 : w...

  • Page 11

    Novar-nrc kmb systems 11 2.4 parameters 50, 51, 52 – instrument address, communication rate and communication protocol / nrc86 response timeout parameter 50 specifies the instrument address for remote control and monitoring of the pfc with the retis ot the envis program. But this function cannot be ...

  • Page 12

    Novar-nrc kmb systems 12 in principle, one of two remote control modes can be activated - either the i/o or the rcc mode : • rcc mode the rcc mode (remote controlled cos ϕ ) is designated for remote control of target power factor value. Simultaneously, a remote controlled outputs can be driven by ad...

  • Page 13

    Novar-nrc kmb systems 13 in both of the remote control modes, actual state of the master pfc broadcast can be activated. These options are identified with additional decimal point. When set, the pfc broadcasts its complete actual state (all measured quantities actual values, outputs state etc.) duri...

  • Page 14

    Novar-nrc kmb systems 14 3. Nrc 86 remote controller the unit is designed for power factor compensation systems either with remote controlled pf or with remote controlled outputs. The unit operates in combination with special version of novar power factor controller – novar1xxx nrc. The unit is avai...

  • Page 15

    Novar-nrc kmb systems 15 3.2 operation 3.2.1 remote controlled power factor (cosinus) mode – the „rcc“ mode up to five pulse signals can be connected to the nrc86 unit. A pulse of correct duration on one of inputs 1 ÷ 5 is evaluated as target pf serial number request. The unit saves the number into ...

  • Page 16

    Novar-nrc kmb systems 16 the parameter value is controlled and refreshed with each command received from a novar1xxx nrc pfc, it is not necessary to set it manually. In case of power failure, the last valid value of the parameter is stored in the unit memory and automatically loaded after the power ...

  • Page 17

    Novar-nrc kmb systems 17 3.3.3 parameter 05 – number of processed outputs (in i/o mode) the parameter is relevant in i/o mode only (it is not displayed in rcc mode). It defines how many of the unit outputs starting from o1 output will be used as remote controlled outputs. As default, the parameter i...

  • Page 18

    Novar-nrc kmb systems 18 3.3.8 parameter 30 – logic inputs status for logic inputs status and functionality checking actual state of all logic inputs i1 ÷ i8 is displayed in the parameter. The inputs states are displayed in order from left to right (the leftmost is i1 , the rightmost i8). Character ...

  • Page 19

    Novar-nrc kmb systems 19 3.4.3 logic inputs the nrc86 unit can have up to 8 galvanically isolated logic inputs (depending on unit model). The inputs are passive – a voltage of appropriate level ( specified in technical parameters, see below ) must be applied. For direct voltage inputs the applied vo...

  • Page 20: 4.  Putting In Operation

    Novar-nrc kmb systems 20 4. Putting in operation 4.1 remote controlled target pf compensation systems for remote controlled power factor the nrc86-85 24 vdc remote controller is needed. If remote controlled outputs using additional nrc86 units in cascade necessary too it is better to use the nrc86-0...

  • Page 21

    Novar-nrc kmb systems 21 9. Check and optionally change remotely controlled target pf values in parameter 80 of all pfcs. Finally, it is recommended to check functionality of the whole system : step-by-step apply a pulse on the i1÷ i5 inputs of the nrc86 and check response of all connected pfcs. 4.2...

  • Page 22

    Novar-nrc kmb systems 22 • the nrc86 unit(s) should not indicate any alarm or the external alarm only can be active ( the alarm of supervisory pfc, transmitted to the unit(s)) finally, it is recommended to check the remote control failure (no. 15) actuation alarm functionality, for example by discon...

  • Page 23: 5.  Connection Examples

    Novar-nrc kmb systems 23 5. Connection examples remote controlled target pf compensation system with nrc86 remote controller xn 1 2 xyw x113 + - 9 10 11 12 13 14 2 25 + r1 r2 r3 r4 r5 napájení 24 vdc regulace jalového výkonu signalizace regulace jalového výkonu s1 s2 s3 s4 s5 26 27 28 29 + = + + - 1...

  • Page 24: Nrc86 Remote Controllers

    Novar-nrc kmb systems 24 remote controlled outputs compensation system with two nrc86 remote controllers n o v a r 1 1 1 4 n r c 1 a n r c 8 6 -0 7 2 3 0 v a c l 1 l 2 l 3 n 1 0 a c 1 c 7 r e m o te c o n tr o lle r 7 1 2 3 4 5 6 8 20 : 21 : f a il s ta te 30 : in pu t st a te a la rm s ta te 1 : m ...

  • Page 25

    Novar-nrc kmb systems 25 combined remote controlled target pf and remote controlled outputs compensation system with nrc86 remote controllers, wireless remote outputs connection block diagram x n x y w x 1 1 3 n a p á je n í 2 4 v d c r e g u la c e ja lo v é h o v ý k o n u s ig n a li z a c e re g...

  • Page 26

    Novar-nrc kmb systems 26 6. Nrc86 remote controller technical specifications parameter nrc86 model nrc86-85 24vdc nrc86-07 230vac aux. Supply voltage, power 18 ÷ 36 v dc, 4w 80 ÷ 275 v ac, 43 ÷ 67 hz, 5 va 100 ÷ 300 v dc, 5 w number of output relays 5 7 output relay load rating 250 v ac / 4 a 110 v ...

  • Page 27: Warranty Certificate

    Novar-nrc kmb systems 27 7. Maintenance, troubleshooting nrc86 remote controller does not require any maintenance. For reliable operation you only have to comply with the operating conditions specified and prevent mechanical damage to the instrument. In the event of the product’s breakdown, you have...