Remedy of faults
Malfunction
Cause
Remedy
Water is extremely soiled or contaminated.
− Remove algae and leaves from the pond.
− Clean the pond thoroughly.
− Change the water, remove algae and leaves from
the pond.
− Clean the pond thoroughly.
− Change the water.
Insufficient circulation of the pond water.
− Ensure that the pond water is sufficiently recircula-
ted.
− Place the pump in a different position.
− Use a pump with a higher circulation capacity.
Capacity of the UVC lamps is not sufficient.
Change the UVC lamps after 12000 operating hours.
The quartz glass is soiled.
Clean the quartz glass (
→ Cleaning the quartz glass)
The quartz glass is scratched.
− Replace the quartz glass (→ Cleaning the quartz
glass)
− If the profile is worn, replace the cleaning rotor
(
→ Cleaning the quartz glass)
Unit is deactivated.
Exit
O
O
f
f mode and select Eco mode.
Water remains cloudy (green water).
The quartz glass is soiled as the cleaning
rotor is not rotating.
− Inspection: Remove the unit head, switch
on the filter pump and shine a torch into the
casing.
− Clean the cleaning rotor and quartz glass (→ Clea-
ning the quartz glass)
− If the delivery rate of the pump is < 10000 l/h, use
an inlet nozzle for the drive of the cleaning rotor.
− If the profile is worn, replace the cleaning rotor
(
→ Cleaning the quartz glass)
Power plug not connected.
Connect the power plug.
Unit is not functional.
Connection defective.
Check the electrical connection.
Lamp does not light up.
Safety switch-off activated.
For safety reasons, the lamps are deactivated when
the unit is opened.
Defective lamps are indicated on the display by
E
E
r
r
L
L
1
1 or
E
E
r
r
L
L
2
2.
Drips forming at the connection to the
filter.
Seal is not sufficient.
− Check the seating of the seal.
− Tighten the screw connection.
The locking screw has not been undone.
Undo the locking screw.
The unit head cannot be removed.
A vacuum has formed inside the unit.
Switch on the unit and allow it to warm up for a few
minutes. Subsequently pull the power plug and
remove the unit head.
Display of different temperature values
when several OASE units with temperatu-
re display are used.
Tolerance range of the temperature measu-
rement
The temperature probes are precise to
± 1 °C. If other
units with temperature display are operated, the
displayed temperature values may differ from one
another by up to 2 °C.
− Recommendation: The arithmetic mean of all
displayed values produces a useful approximation of
the actual temperature.
− Greater deviations are possible if the units are
exposed to direct sunlight. For this reason, ensure
that the unit is installed such that it is protected from
direct sunlight.