18 - gb - translation of the original operating instructions information about these operating instructions welcome to oase living water. You made a good choice with the purchase of this productfiltoclear 12000/16000/20000/30000. Prior to commissioning the unit, please read the instructions of use c...
Page 10
19 - gb - unit configuration and function description unit configuration figure (b) object 1 water return socket, for the return of filtered pond water 2 water inlet socket, for the inlet of soiled pond water 3 cleaning handle, the foam filters are compressed by pulling the handle up 4 uvc unit head...
Page 11
20 - gb - oase recommend: − as a filter starter: oase biokick. − as a reference value for the fish population in the pond: approx. 60 cm fish length in 1 m³ pond water. − as a pond pump for filtoclear 12000: aquamax eco 8000. − as a pond pump for filtoclear 16000: aquamax eco 10000. − as a pond pump...
Page 12
21 - gb - − the power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to be disposed of. − only operate the unit if no persons are in the water! − the unit, the connections and plugs are not water-proof and must not be routed or installed in water. − ...
Page 13
22 - gb - installation figure (c) 1 ½" hoses or 2" hoses can be connected to the unit. The respective hose connectors are part of our scope of delivery. Recommendation: use 2" hoses to convey the water through the lines at a minimum pressure loss. If you use a filter starter, fill the product into t...
Page 14
23 - gb - commissioning/start-up attention! Sensitive electrical components. Possible consequence: the unit will be destroyed. Protective measure: do not connect the unit to a dimmable power supply. Oase recommends the use of biokick (oase filter starter bacteria): − for the initial start-up − after...
Page 15
24 - gb - maintenance and cleaning removing/inserting the uvc unit head attention! Dangerous electrical voltage. Possible consequences: death or severe injury. Protective measures: switch off the mains voltage prior to carrying out work on the unit. Removing the uvc unit head figure (e) how to proce...
Page 16
25 - gb - − vigurously pull up the cleaning handle (3) several times, then push the handle down against the stop ("pumping" action). The foam filters will be rinsed by this action. − as soon as only clean water appears in the transparent hose connector (20), turn the function switch (5) counter- clo...
Page 17
26 - gb - replacing the uvc lamp attention! Dangerous electrical voltage. Possible consequences: death or severe injury. Protective measures: isolate the unit prior to reaching into the water and carrying out any work on the unit. Secure the unit from being switched on inadvertantly. Attention! Brea...
Page 18
207 tech nisch e dat e n de t yp abm es s ungen g ewic ht bem es s ungs s pannun g leis tu ngs auf na hm e kab el län ge ans c hlüs s e f ilter vo lum en uvc- lam pe m a x . T eic hvolum en w a ss er te m per atur gb t ype dim ens ions w eight rated v olt age po w er c o ns um ption cabl e l eng th ...