Oase Filtral 5000 UVC Operating Instructions Manual - page 11
11
- GB -
Remove the self-tapping screw (32). Unscrew the clamping screw (34) from the unit head (31) by turning counter-
clockwise. Pull off the quartz glass (33) including the O ring (35) by exerting a slight rotary movement. Pull out the UVC
lamp (36) and replace. Check the quartz glass (33) and the O ring (35) for damage. Insert the quartz glass (33) includ-
ing the O ring (35) against the stop in the unit head (31). Tighten the clamping screw (34) clockwise up to the stop.
Turn in and tighten the self-tapping screw (32).
Assembly of the UVC clarifying unit (Figures R, S)
Check the O ring (37) at the unit head (31) for damage. Place the O ring (37) on the recess at the unit head (31), then
carefully push the UVC water housing (26) against the stop on the unit head (31) by applying light pressure. While
doing so, slightly turn the UVC water housing (26) to ensure that the tenons and the grooves of the bayonet closure
intermesh. Turn the UVC water housing (26) clockwise up to the stop.
Assembly of the unit (Figure T-V)
Pumpe (28) mit Überwurfmutter am UVC-Wassergehäuse (26) festschrauben. Place the bio surface element (23) and
gravel bags (24) in the bottom strainer casing (2). Place the aeration stone (25) between the gravel bags (24). Ensure
that the hose is not kinked. Place the foam filters (3, 22) in the bottom strainer casing (2). Insert the UVC clarifying unit
including the pump (20). Attach the top strainer casing (1) and press it onto the bottom strainer casing (2) until the
clamps engage in the bottom strainer casing. Important: Lead the connection cable (7) through the cable opening in
the bottom strainer casing (2) and route the cable such that pinching is avoided.
Pos: 39 /Pumpen/Schlammsauger/PondoRell/Lagern PondoRell 3000, 5000 @ 5\mod_1161768826819_121.doc @ 28583
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water at a frost-free place. Do not flood the power plug!
Pos: 40 /Pumpen/Schlammsauger/PondoRell/Verschleißteile PondoRell 3000, 5000 @ 0\mod_1127677370702_121.doc @ 6738
Wearing parts
The UVC lamp, the different filters and the rotor are wear parts and are excluded from the warranty.
Pos: 41 /Pumpen/Schlammsauger/PondoRell/Entsorgung PondoRell 3000, 5000 @ 0\mod_1127679338360_121.doc @ 6788
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special disposal. Ask your
specialist dealer.
Pos: 42 /Pumpen/Schlammsauger/Filtral 5000 UVC GB/Störungen Filtral 5000 UVC GB @ 6\mod_1187861039508_121.doc @ 37546
Malfunctions
Malfunction Cause Remedy
The unit is not operating
No mains voltage
Check mains voltage
Excessive pressure losses in the hoses
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Intake openings blocked
Clean housing
Filters clogged
Clean filters
Rotor blocked
Clean rotor
Pond extremely dirty
Remove algae and leaves from the pond,
exchange the water
Delivery insufficient or not consistent,
Cloudy water
Quartz glass tube soiled
Remove UVC filter and clean the quartz glass
tube
UVC lamp does not light up
UVC lamp defective
Replace the UVC lamp
Unit switches off after a short running period
Water temperature too high
Note maximum water temperature of +35°
Pos: 43 /Alle Produkte/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630