Switching off the unit
Disconnect the power plug.
– When the pump is switched off, re-
sidual water in the hose may flow
back and out of the pump intake.
N O T E
Do not use the unit for long-term opera-
tion. Otherwise this will impair the operat-
ing life of the unit accordingly.
N O T E
Rinse the pump with clean water after
use.
REMEDY OF FAULTS
Malfunction Cause
Remedy
Pump does not start.
Power supply interrupted
Check the fuse and electri-
cal plug connections.
Metal contacts soiled
Clean the metal contacts.
Pump switches off after a
short running period.
Overload protection has
switched the pump off due
to overheating.
Clean the intake and
pressure hose.
Allow the pump to cool
down.
Pump does not switch off
Metal contacts soiled
Clean the metal contacts.
The pump is running but is
not delivering, or the deliv-
ered quantity is insufficient
Pressure hose blocked
Route the pressure hose
without kinks
Check the outlet and
clean if necessary
Intake blocked
Clean the intake
Air in the pressure hose
Expel the air from the
pressure hose.
If applicable:
Non-return valve incorrectly
fitted in the pressure hose
or clogged
Correctly fit the non-re-
turn valve.
Clean the non-return
valve.
Impeller defective or worn
Contact OASE
The impeller may only be
replaced by the OASE
Service.