Oase Vitronic 11 W Operating Instructions Manual - page 10
- EN -
16
Commissioning/start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Prior to reaching into the water, switch off the mains voltage to all units used in the water.
Switch off the mains voltage prior to carrying out work on the unit.
Prerequisite
Switch the pump on first, then switch on the UVC clarifying unit.
Check all connections for leaks.
Switching ON/switching OFF
Switching on: Insert the power plug into the socket.
– The unit switches on immediately.
Switching off: Disconnect the power plug.
Check the function.
Vitronic 11 W
F
The function display is lit when the UVC lamp is switched on.
Vitronic 18 W / 24 W / 36 W / 55 W
G
The function display is lit when the UVC lamp is switched on.
The transparent stepped hose adapters are lit when the UVC lamp is switched on.
Remedy of faults
Malfunction Cause
Remedy
The performance of the unit is not satisfactory
The water is extremely soiled
Remove algae and leaves from the pond,
change the water
The quartz glass is soiled
Clean the quartz glass
The UVC lamp capacity is exhausted
The lamp must be replaced after 8000 operat-
ing hours
Flow rate is too high
Reduce the pump output
UVC lamp is not lit
Power plug not connected
Connect power plug
UVC lamp defective
Replace the UVC lamp
Connection defective
Check electrical connection
UVC overheated
Vitronic 55: UVC automatically switches on
when it has cooled down
Wear parts
The following components are wear parts and are excluded from the warranty:
UVC lamp, quartz glass and O ring for quartz glass