Oasis ELITE AC14 Installation And Instruction Manual

Manual is about: SWIMMING POOL HEAT PUMP UNIT

Summary of ELITE AC14

  • Page 1

    Swimming pool heat pump unit installation & instruction manual.

  • Page 2

    Contents 1. Preface 2. Specifications 2.1 performance data of swimming pool heat pump unit 2.2 dimensions for swimming pool heat pump unit 2.3 how to disassemble the units 2.4 3. Installation and connection 3.1 installation of system 3.2 swimming pool heat pumps location 3.3 how close to your pool? ...

  • Page 3

    1. Preface in order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before y...

  • Page 4

    2 2.Specification 2.1 performance data of swimming pool heat pump unit *** refrigerant : r410a unit heating capacity heating power input running current power supply compressor quantity compressor fan number fan power input fan rotate speed fan direction noise water connection water flow volume wate...

  • Page 5

    2.Specification 2.1 performance data of swimming pool heat pump unit *** refrigerant : r410a unit heating capacity heating power input running current power supply compressor quantity compressor fan number fan power input fan rotate speed fan direction noise water connection water flow volume water ...

  • Page 6

    2.2 the dimensions for swimming pool heat pump unit 2.Specification 4 oasis elite ac9/oasis eliteac14/ 375 623 956 552 water inlet 40 water outlet 40 11 4 350 356 18.5 oasis elite ah9/oasis eliteah14.

  • Page 7

    Oasis eliteac18 5 2.Specification 1116 886 500 790 460 511 400 11 6 water inlet 40 water outlet 40 / oasis eliteah18.

  • Page 8

    6 2.3how to disassemble the units. 2.Specification attention: 1. Please be careful when handle with the front plate in case of damage; 2. During this process, please attention to protect the wire between the button on the front plate and electrical box. Pull up the front plate move forward the front...

  • Page 9

    7 2.Specification 2. 1. Pull out power cord from the electrical box, and fix it at the place "a" as showed in the first image below; after fixing it at "a", draw it out from the bottom of the heat pump as showed in the second image. A power cord power cord 2.4 how the power cord go.

  • Page 10

    Installation items: the factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer. 3.1 installation illustration attention: please follow these steps when using for the first tim...

  • Page 11

    The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh air - 2. Electricity - 3. Pool filter piping the unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier. Unlike a gas heater, it has no draft ...

  • Page 12

    3.4 swimming pool heat pumps plumbing location: connect the unit in the pool pump discharge (return) line downstream of all filter and pool pumps, and upstream of any chlorinators, ozonators or chemical pumps. Standard model have slip glue fittings which accept 32mm or 50 mm pvc pipe for connection ...

  • Page 13

    3.5 swimming pool heat pumps electrical wiring note: although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit. ...

  • Page 14

    12 4. Usage and operation 1.Function of controller main display area aux. Display area 1 2 3 4 1 4 5 3 temp in set c f a min on off temp out vol mode set 2 mode set clock 1 button function no symbol name function on/off mode up press this button can start up or shut down the unit, cancel the current...

  • Page 15

    13 a electric- heating on off timer on timer off it is showed when the unit sets the timer on it is showed when the unit sets the timer off in out temp temperature vol f min fahrenheit c set symbol meaning function cooling heating automatic it is showed when the unit in cooling mode. It is showed wh...

  • Page 16

    14 2. The controller usage 2.1 starting up and shutting down press for 0.5 second can switch between unit on and unit off water outlet temperature actual mode display off unit 2.2 modes switching if it is cold/ heat unit, in the main interface, you can switch different modes of cooling, heating, aut...

  • Page 17

    A 15 4. Usage and operation 2.3 t emperature setting press or press or to change the value press to save value setting cooling target temperature mode set temp in c temp out mode set set temp c temp out mode set set temp c temp out mode set temp in c temp out mode set mode set 2.4 clock setting in t...

  • Page 18

    4. Usage and operation temp in c temp out mode set temp in c temp out mode set press hour minute flashing temp in c temp out mode set flashing press temp in c temp out mode set press or temp in c temp out mode set press to save hour value setting temp in c temp out mode set press or temp in c temp o...

  • Page 19

    17 2.5 timer setting in the main interface press hold on 2 seconds and "on" is flashing, at this time, you can set the timer on means the unit timer is on then press again and hold on 2 seconds and "off" is flashes you can set the timer off means the unit timer is off . If you want cancel the timer ...

  • Page 20

    18 temp in c temp out mode set on flashing off temp in c temp out mode set press on press or off temp in c temp out mode set on off temp in c temp out mode set on off press press or temp in c temp out mode set on off temp in c temp out mode set press on off the timer on and off has been set flashing...

  • Page 21

    19 2.6 cancel the timer setting press for 2s and "on" is flashing at this time, press to cancel the setting of timer on; it is the same way to cancel the setting of timer off . For example temp in c temp out mode set on off the timer on/off has been set press for 2s temp in c temp out mode set on of...

  • Page 22

    20 2.4 keyboard lock to avoid mis-operation, please lock the controller after parameter setting. At the main interface, press for 5 seconds, the keyboard will be locked. When the keyboard is locked, press for 5 seconds, the keyboard will be unlocked. Notes: when the unit is in alarming state, the ke...

  • Page 23

    21 28 28 27 meaning heating inlet target temp. Adjustable adjustable adjustable 3. Parameter table cooling inlet target temp. Auto inlet target temp. Remark default 4. Usage and operation.

  • Page 24

    4. Power button operating instructions 4.1 when the power button is lighted, it shows that the unit is at work. You can press the power button to turn it off, then the light will also be off. 4.2 when the light of power button is out, it shows that the unit is stand by. You can press the power butto...

  • Page 25

    23 check the water supply device and the release often. You should avoid the condition of no water or air entering into system, as this will influence unit's performance and reliability. You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of clogged fi...

  • Page 26

    5.2 trouble shooting guide 5. Maintenance and inspection 24 pc1001 temp. Is too much different between water-inlet and outlet antifreezing under cooling mode the primary anti-freezing protection start. The second anti-freezing protection start malfunction ambient temp. Sensor failure communication f...

  • Page 27

    6.Appendix 4 4 3 3 out1 out2 cn2 cn1 out3 ac-n cn19 cn4 cn3 gnd 12v net gnd di01 gnd gnd gnd gnd gnd gnd gnd gnd gnd ai01 out4 out5 pc1001 pc1001 di02 di03 di04 di05 gnd di06 ai02 ai03 ai04 ai05 gnd ai06 cn1 cn2 cn6 cn19 5v cn16 gnd 21 22 23 24 primary transformer secondary transformer without use e...

  • Page 28

    1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer. For europe market 2. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have be...

  • Page 29

    (2) cable specification 6.Appendix 27 when the unit will be installed at outdoor, please use the cable which can against uv. 1. Single phase unit 10~16a 16~25a 25~32a 32~40a 40 ~63a 63~75a 75~101a 101~123a 123~148a 148~186a 186~224a phase line mcb creepage protector signal line 2 n 0.5mm nameplate m...

  • Page 30

    2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 34 27 32 oasis eliteac9 6.Appendix 28.

  • Page 31

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 code 2004-1437 20000-140150 2004-1445 20000-140150 2000-3603 2004-1445 2000-3505 2000-3909 2000-3501 20000-370003 95005-310145 2001-3630 ...

  • Page 32

    2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 32 34 27 33 oasiselite ac14 6.Appendix 30

  • Page 33

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 code 2004-1437 20000-140150 2004-1445 20000-140150 2000-3603 2004-1445 2000-3505 2000-3909 2000-3501 20000-370003 20000-360006 95005-3101...

  • Page 34

    19 25 20 21 22 23 24 18 26 27 28 1 2 4 3 5 17 16 15 38 29 32 31 33 30 35 36 37 34 oasiselite ac18 6.Appendix 32 8 6 7 9 13 10 12 11 14.

  • Page 35

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 code 20000-140150 2004-1444 2000-3603 20000-140179 2001-3605 32009-210285 20000-110208 32009-210313 2000-3524 2000-3502 2000-3676 20000-...

  • Page 36

    2 3 4 5 6 7 8 9 10 11 15 16 17 18 19 20 21 22 23 24 26 27 28 29 31 25 30 oasis eliteah9 6.Appendix 34 12 13 14.

  • Page 37

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 code 20000-140150 2004-1445 20000-140150 2000-3603 2000-3505 2000-3909 2000-3501 20000-370003 95005-310145 2001-3630 4000-3901 part name ...

  • Page 38

    2 3 4 5 6 7 10 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28 29 30 32 25 31 oasiseliteah14 6.Appendix 36.

  • Page 39

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 code 20000-140150 2004-1445 20000-140150 2000-3603 2000-3505 2000-3909 2000-3501 20000-370003 20000-360006 95005-310145 2001-3630 4000-39...

  • Page 40

    19 24 20 21 22 23 18 25 26 27 8 6 1 2 4 3 5 7 9 13 10 17 16 12 11 15 14 37 28 31 30 32 29 34 35 36 33 oasiseliteah18 6.Appendix 38.

  • Page 41

    No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 no. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 note 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 2 code 2004-1444 2000-3603 20000-140179 2001-3605 32009-210285 20000-110208 32009-210313 2000-3524 2000-3502 2000-3676 20000-360006 95005-...

  • Page 42

    Note.

  • Page 44

    Code 20150616-0001.