    Swimming pool heat pump unit installation & instruction manual.

  • Page 3

    Contents 1. Preface 1 2. Specifications 2 2.1 performance data of swimming pool heat pump unit 2 2.2 the dimensions for swimming pool heat pump unit 3 3. Installation and connection 4 3.1 installation illustration 4 3.2 swimming pool heat pumps location 5 3.3 how close to your pool? 5 3.4 swimming p...

  • Page 4

    1. Preface 1 in order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before...

  • Page 5

    2 2.Specification 2.1 performance data of swimming pool heat pump unit *** refrigerant : r410a unit model oasis c17br heating capacity kw 17 btu/h 54608 heating power input kw 2.8 running current a 12.8 power supply 230v~/50hz compressor quantity 1 compressor rotary fan quantity 1 fan power input w ...

  • Page 6

    3 2.Specification 2.2 the dimensions for swimming pool heat pump unit model:oasis c17br e a g water outlet Φ40 water inlet Φ40 unit:mm type size oasis c17br a 1156 b 867 c 487 d 447 e 790 f 470 g 430 h 113 i 370 f h i d b c.

  • Page 7

    4 3.Installation and connection 3.1 installation illustration chlorinator cell water outlet valve water supply water inlet sand filter pool water pump (or other type filter) installation items: the factory only provides the main unit and the water unit; the other items in the illustration are necess...

  • Page 8

    5 3.Installation and connection 3.2 swimming pool heat pumps location the unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh air - 2. Electricity - 3. Pool filter piping the unit may be installed virtually anywhere outdoors. For indoor po...

  • Page 9

    6 3.Installation and connection 3.4 swimming pool heat pumps plumbing the swimming pool heat pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass(please set the flow rate according to the nameplate). The water pressure drop is less than 10kpa at ...

  • Page 10

    7 3.Installation and connection 3.5 swimming pool heat pumps electrical wiring note: although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against ...

  • Page 11

    8 4. Usage and operation 1. Function of controller main display area off on f min set temp in 3 temp out mode 2 set aux. Display area 1 4 5 1)button function no symbol name function 1 on/off press this button can start up or shut down the unit, cancel the current operation or back to the upper inter...

  • Page 12

    9 4. Usage and operation 2)display function symbol meaning function cooling it is showed when the unit in cooling mode. Heating it is showed when the unit in heating mode and flashed in defrosting. A automatic it is showed when the unit in automatic mode. Electric- heating it is showed when the unit...

  • Page 13

    4. Usage and operation 10 a ” temp out mode set press “ ” mode set ” temp out mode set mode set 2. The controller usage 2.1 starting up and shutting down in the off interface, press" " for 0.5s can start up the unit, and aux. Display-area shows water outlet temperature; in the running interface, pre...

  • Page 14

    11 4. Usage and operation set 2.3 temperature setting in the main interface,press“ ”or“ ” and the current mode target- temperature flashes, then press“ ”to increase the temp.Value, or press“ ”to decrease it. Press“ mode ”can save setting parameter and back to the main interface; press“ ”can not save...

  • Page 15

    12 4. Usage and operation temp in c temp mode out set press“ ” flashing ” temp in c temp mode out set press“ to save hour value setting ” flashing temp in c temp out mode set ” temp in c temp mode out set press“ ” to save minute value setting temp in c temp mode out set hour minute flashing flashing...

  • Page 16

    13 4. Usage and operation on c press“ ” temp in for 2 second temp out mode set press“ ” flashing on press“ or“ ” ” in temp c temp out mode set 2.5 timer setting in the main ”hold on 2 seconds and "on" is flashing, at this time, you can set the timer on(means the unit timer is on) ,then ”again and ho...

  • Page 17

    14 4. Usage and operation flashing flashing flashing temp in temp out on off c mode set press“ ” temp in temp out on off c mode set press“ ” flashing flashing or“ ” flashing flashing on on off off temp in temp out c mode set press“ ” temp in temp out c mode set press“ ” or“ ” flashing flashing the t...

  • Page 18

    15 4. Usage and operation 2.6 cancel the timer setting press“ ”for 2s and "on" is flashing , at this time, press ”to cancel the setting of timer on; it is the same way to cancel the setting of timer off . For example: the timer on/off has been set "on" is flashing on on temp off c press“ ” temp off ...

  • Page 19

    16 4. Usage and operation 2.4 keyboard lock to avoid mis-operation, please lock the controller after parameter setting. At the main interface, press“ ”for 5 seconds, the keyboard will be locked. When the keyboard is locked, press“ ”for 5 seconds, the keyboard will be unlocked. Notes: when the unit i...

  • Page 20

    17 4. Usage and operation 3. Parameter table meaning default remark heating inlet target temp. 27℃ adjustable cooling inlet target temp. 27℃ adjustable auto inlet target temp. 27℃ adjustable remark: the wire controller can display the temperature unit as "℉" or "℃" according to the unit model you bo...

  • Page 21

    18 5. Maintenance and inspection malfunction table the common failure cause and solution. Malfunction display canse solution water inlet temp. Sensor failure p01 the water inlet temp. Sensor is open or short circuit check or change the water inlet temp. Sensor water outlet temp. Sensor failure p02 t...

  • Page 22

    19 6.Appendix 1.Connection of pcb illustration connections explanation: no. Symbol meaning 1 out1 compressor of system1(220-230vac) 2 out2 water pump(220-230vac) 3 out3 4way valve (220-230vac) 4 out4 high speed of fan motor(220-230vac) 5 out5 low speed of fan motor(220-230vac) 6 ac-n neutral wire 7 ...

  • Page 23

    6.Appendix 20 caution & warning 1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer.(for europe market) 2. This appliance can used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experie...

  • Page 24

    21 6.Appendix (2) cable specification 1. Single phase unit nameplate maximum current phase line earth line mcb creepage protector signal line no more than 10a 2×1.5mm 2 1.5mm 2 20a 30ma less than 0.1 sec n×0.5mm2 10~16a 2×2.5mm 2 2.5mm 2 32a 30ma less than 0.1 sec 16~25a 2×4mm 2 4mm 2 40a 30ma less ...

  • Page 25

    22 6. Appendix 6.2 explosive view of the unit model: oasis c17br 8 9 10 11 12 13 14 15 16 17 18 19 7 20 6 21 22 5 23 4 3 2 1 33 32 31 30 29 28 27 26 25 24 no. Code name quantity no. Code name quantity 1 20000-110278 compressor 1 19 2000-3509 fan motor capacitor 1 2 32009-210606 chassis 1 20 2000-351...

  • Page 26

    Note:.

  • Page 27

    Oasis technologies ltd ph 09 5358891 www.Oasisheatpumps.Com.

  • Page 28

    Correct disposal of this product this marking indicates that product should not be disposed with other household wastes throughout the eu. To prevent possible harm to the environment to human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material...