Ocean Aire AIR BOSSR410A User Manual

Manual is about: Portable Air-Cooled Spot Cooler

Summary of AIR BOSSR410A

  • Page 1

    Engineering, installation and service manual pac60 pac12 air boss portable air-cooled spot cooler r410a models.

  • Page 2

    Table of conents page general description …................................. 1 product data and specifications ............ 2 unit description standard features.................................. 3 applications / operation.......................... 4 electrical...........................................

  • Page 3

    Nomenclature p ac 24 1 2 portable voltage air-cooled phase 1 or 3 nominal capacity capacity rating nominal capacity 12..........12,000 btu/hr 18..........18,000 btu/hr 24..........24,00 btu/hr 36..........36,000 btu/hr 60……...60,000 btu/hr general description the oceanaire airboss is a portable air-...

  • Page 4: Airboss

    2 airboss deluxe air-cooled portable air conditioners specifications subject to change without notice model: pac 1211 1811 2412 3612 3632 3634 6012 6032 6034 cooling capacity 1 11,800 16,800 24,020 36,050 36,050 36,050 60,050 60,050 60,050 voltage (v/phase) at 60hz 115/1 208-230/1 208-230/1 208-230/...

  • Page 5

    Standard features cabinet the airboss series cabinet is constructed of 18 gauge steel with a gray polyester powder coated finish that will compliment any decor. The entire cabinet is insulated with a sound- absorbing insulation for cool, quiet comfort. All units come equipped with handles and swivel...

  • Page 6: “Hot”

    4 applications spot cooler the air boss can be used in an open environment to cool specific objects or "spots". Spot cooling is a convenient and economical way to provide air conditioning where cooling the entire space is impractical. Cool air is discharged from the unit and is directed where it is ...

  • Page 7

    Service cord all airboss series units are equipped with the standard ten foot long service cord with plug configurations and receptacle requirements as shown in this chart. Pac1211, pac1811, pac2412 and pac3612 units come with lcdi (leakage current detection & interruption) devices that serve as a m...

  • Page 8

    6 condensate reservoir tank for air boss models pac12, pac18, pac24 and pac36, a 5-gallon polyethylene tank is provided standard, to collect condensate. The tank is located in the lower, front section of the unit. A high water level cut-out switch is used to stop the compressor and condenser fan aut...

  • Page 9: Accessories

    7 ck-12pl (2 req’d for 2dcp-4 ck-12 ck-16 2dda-6 2dda-10 2dda-16 2nk-1 2nk-2 2nk-3 dep-10 2dep-12 dep-16 2dcp-1 2dcp-2 2dcp-4 air boss unit accessories.

  • Page 10

    Pac – air boss accessories nozzle kit 2nk-1 (2 x 4-inch) pac12 2nk-2 (2 x 6-inch) pac18, 24 2nk-3 (2 x 8-inch) pac36, 60 evaporator return air plenum dep-10 (10-inch round) pac12 2dep-12 (12-inch round) pac18, 24 dep-16 (16-inch round) pac36, 60 discharge duct adapter 2dda-6 (6-inch round) pac12 2dd...

  • Page 11

    Accessories ceiling panel duct kit, ck-12, ck-16 a ceiling panel kit is available for discharging the condenser air above a drop ceiling.. The ceiling panel duct kits are furnished with a white vinyl coated flexible duct that allows for convenient installation. A 2ft x 2ft ceiling duct- panel is inc...

  • Page 12

    Accessories discharge air nozzle kit assembly (2nk) the optional discharge nozzle kits are used to direct the condi- tioned air to a specific target area. By concentrating the airflow, the nozzles increase the air velocity towards production lines to cool personnel or equipment. In server rooms, the...

  • Page 13: 2Dcp-1 And 2Dcp-2

    Accessories condenser return air plenum, 2dcp condenser return air plenums are available for installations where it is required to duct air to the inlet of the condenser. The plenum easily attaches with one screw to the back of the unit, and is provided with flange(s) for connecting 12-inch flexible...

  • Page 14

    Accessories evaporator return air plenum, dep evaporator return air plenums are available for installations where it is required to duct air to the inlet of the evaporator. The evaporator return air plenums allow the user to connect round duct (flexible or rigid) to the return air intake to reduce a...

  • Page 15

    Accessories discharge duct adapter, 2dda and dda discharge duct adapters are available for applications where ducted evaporator discharge is required. The adapters can be easily installed on the unit without fasteners, and be installed for either vertical or horizontal ducting. The standard discharg...

  • Page 16: Warranty

    Installation instructions receiving—inspection : upon receiving your air boss unit, inspect the packaging for any damage. All units are shipped on a skid, and packaged in a triple-wall carton for added protection. In shipment, some wear may occur on the packaging. If the packaging is heavily damaged...

  • Page 17

    Thermostat operation fan when the power is connected, the lcd screen on the thermostat will illuminate. Pressing the fan button once, will turn on the evaporator fan blower. To turn the blower off, push the fan button once again. Cooling mode Ä to operate unit for cooling, push mode button to displa...

  • Page 18

    Replacement procedure for parts it is recommended that all oceanaire units be serviced by a licensed technician warning—to avoid injury, disconnect unit power prior to servicing a. Fan motors 1. Remove cabinet's left-side panel (when looking at the front of the unit). 2. Evaporator fan motor—disconn...

  • Page 19

    Troubleshooting guide the following steps and procedures are recommended for correcting the problems indicated. In the event that the problem can not be corrected, service may be required. Service should be performed by a qualified air conditioning service technician problem: unit does not power up ...

  • Page 20

    18 preventive maintenance airboss spot coolers are designed to last a long time and to give maximum performance and reliability with minimum maintenance. To prolong the life of the unit, regular maintenance must be performed as specified below: blower motors the motors on all units have permanently ...

  • Page 21: Pac     Interior

    Pac interior high pressure switch condenser blower condenser coil capillary tube strainer control box casters evaporator blower motor capacitors evaporator coil evaporator drain pan condensate tank condensate tank tray water level detection control 19.

  • Page 22

    20 piping schematic air-cooled spot cooler suction line discharge line filter/ drier access valves compressor evaporator blower condenser coil evapotator coil capillary tubes hp reset air air condenser blower refrigerant flow.

  • Page 23

    Condensate tank full switch nc no com o a cean ire optional condensate pump kit pc-1p (115v) or pc-2p (208-230v) install safety switch in low- voltage loop replacing condensate tank full switch 21.

  • Page 24

    O a cean ire www.Oceanaire-inc.Com condensate tank “full” switch nc no com plug l15-30p optional condensate pump kit pc-2p (208-230v) install safety switch in low-voltage loop replacing condensate tank full 22.

  • Page 25

    O a cean ire www.Oceanaire-inc.Com condensate tank full switch nc no com plug l16-20p optional condensate pump kit pc-2p (208-230v) install safety switch in low-voltage loop replacing condensate tank full 23.

  • Page 26

    24.

  • Page 27

    O a cean ire www.Oceanaire-inc.Com plug l15-30p 25.

  • Page 28

    26 o a cean ire www.Oceanaire-inc.Com plug l16-20p.

  • Page 29: Use Of Extension Cords

    27 use of extension cords caution: for model pac1211 an extension cord can be used provided it is rated at least 15 amps @ 115 volts with grounding-type attach- ment plug and grounding type connector (load fitting) for model pac1811 an extension cord can be used provided it is rated at least 20 amps...

  • Page 30: Notice

    28 three phase monitor three-phase units can be equipped with monitors for motor protection. The oceanaire three-phase monitor safeguards the unit against incorrect compressor rotation, low-voltage and/or loss of power in any one of the power legs. The monitor is installed in the control box and is ...

  • Page 31

    Manufacturer’s limited warranty the manufacturer (oceanaire, inc.) warrants to the original owner that the product will be free from defects in material or workmanship for a period not to exceed one (1) year from date of installation. If upon examination by the manufacturer the product is shown to h...

  • Page 32: Useful Information

    Useful information model: serial number: date purchased: installed by: for technical support, or to locate a distributor for service parts, contact oceanaire at (847) 583-0311. Please indicate the model number and serial number of the unit to assure proper information and service parts..