2.1
VDR Installation
The E100V float free memory capsule should be mounted in an
external position where it will not be impeded when the float
free mechanism is automatically activated, irrespective of the
orientation of the vessel when it is sinking. The position should
be as high as possible on the vessel, but in a position where it
can still be accessed to manually release and test the E101V.
The ARH101 base should be mounted on a flat surface using
the four screws provided at the positions shown in the
dimensional drawing opposite.
2.1.1
VDR Connection
The E101V Float Free Capsule connects to the Main VDR system via a dedicated Ethernet
connection. Please consult the VDR manufacturers User and Installation Manuals for
further details of integration of the E101V with the VDR. The cable from the E101V housing
should be connected as described below. The E101V memory capsule is completely
isolated from the EPIRB battery and must be connected to either the ships supply (10.8-
31.2Volts DC) or Power Over Ethernet (POE). Please follow the connection diagrams
carefully to ensure correct operation.
•
Feed the cable from the ARH101 housing through the gland of one half of the supplied
waterproof cable housing and connect the RJ 45 connector as shown in the
accompanying table and diagram.
From Float Free
To VDR Network
ARH101
RJ45
POE
Ships Supply
Wire Colour
Pin
Wire Colour
Function
Wire Colour
Function
White/Orange
1
White/Orange
Rx+
White/Orange
Rx+
Orange
2
Orange
Rx-
Orange
Rx-
White/Green
3
White/Green
Tx+
White/Green
Tx+
Blue
4
Blue
DC+(POE)
Do not connect
5
Do not connect
Do not connect
Green
6
Green
Tx-
Green
Tx-
7
Do not connect
Do not connect
Brown
8
Brown
DC-(POE)
Do not connect
White/Blue
-
Do not connect
White/Blue
+ve (24V)
White/Brown
-
Do not connect
White/Brown
-ve (0V)
Screen
Ground