Oceanic DataMax Sport Owner's Manual

Manual is about: Dive Computer DRB

Summary of DataMax Sport

  • Page 1

    Datamax sport owner’s guide (model drb).

  • Page 2

    Ii copyright notice this owner’s guide is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from oceanic.* datamax sport owners guide, do...

  • Page 3

    Iii owner’s guide overview i. The datamax sport is easy to use you’ll see that just a quick glance at the “sport” shows your total dive status. The green, yellow, and red graphic diver interface makes under- standing the datamax sport extremely simple. Ii. Detailed operation guide detailed informati...

  • Page 4

    Iv contents i. The datamax sport is easy to use ............................ 1 introduction ......................................... 2 ii. Detailed operation guide ............................................ 9 operational modes ............................ 10 the sport at a glance ...................

  • Page 5

    The datamax sport is easy to use.

  • Page 6

    2 introduction the datamax sport was designed to be extremely easy to use and under- stand. This owner’s guide is divided into five sections designed to make it easy to learn how to use the “sport.” the first two sections will show you how it performs in most diving situations. Section three describ...

  • Page 7

    3 planning your dive surface mode shows how many dives you have made, your depth, surface interval, and residual nitrogen. Once a minute, it alternates with another display called the “pre dive planning sequence” (fig. 2). When planning your next dive, the pre dive planning sequence provides adjuste...

  • Page 8

    4 made up of two bar graphs that have green, yellow and red markers to indicate normal, caution, and danger zones, respectively. The two graphic displays represent ascent rate and nitrogen loading. When underwater, you can make quick status checks by glancing at the two bar graphs and making sure th...

  • Page 9

    5 if you have not entered decompression, a safety stop made between 15-20 feet is strongly recommended as a standard procedure before completing your ascent. Many divers do this to provide a wider zone of caution from the no- decompression limit. The tissue loading bar graph gives a visual represen-...

  • Page 10

    6 planning for the next dive after reaching three feet upon ascent, the surface mode will display once again. It alternates with the pre dive planning sequence after ten minutes have elapsed. The pre dive planning sequence will show adjusted no- decompression limits based on the nitrogen absorbed du...

  • Page 11

    7 logging your dives immediately after a dive, various information is stored in the datamax sport’s memory that can be accessed in the “dive log mode.” recalling this information gives you a chance to record it in your log book. Up to 9 dives are stored and can be accessed by pressing the activation...

  • Page 12

    8 diving. The datamax sport follows one of the more conservative of these, cited by divers alert network (dan); that divers wait at least twelve hours before flying in pressurized commercial aircraft, and at least 24 or more if making repetitive multi-day or decompression dives. The datamax sport ea...

  • Page 13

    Detailed operations guide.

  • Page 14

    10 operational modes the datamax sport operates in ten different modes. The visual differ- ence between modes is quite evident depending on when you view the display. Even so, mode labels identify the various displays to eliminate confusion. 1. Diagnostic mode/activation diagnostic mode is displayed...

  • Page 15

    11 warning - if the words “low batt” appear immediately after activation, oceanic strongly recommends that you do not dive until you have obtained battery replacement - especially if you are starting out on a multi-day dive trip. Although there will usually be enough voltage to complete one full day...

  • Page 16

    12 warning – the pre dive planning sequence predicts only no- decompression times for subsequent dives. Depending on tank size and air consumption, you may have less time available than shown in the pdps because of air limitations. Pdps no-decompression times are displayed only for depths where ther...

  • Page 17

    13 sion dive mode is replaced every 15 seconds with alternate dive mode for two seconds (fig. 11). Alternate dive mode displays maximum depth (noted by the mode label “max ft”, elapsed bottom time (“bottom”), and temperature. You can easily tell when you are viewing the alternate dive mode because t...

  • Page 18

    14 decompression time displays the total number of minutes required at all ceilings combined. The tissue loading bar graph displays the ceiling depth that you must stay below. After entering decompression, you must immediately change the focus of your dive to getting back to the surface. Upon seeing...

  • Page 19

    15 yellow caution zone or green no decom zone. At the end of all decompres- sion dives, you must focus on reducing your tissue loading as much as possible - by spending as much time as you can at your final safety stop and on the surface - before your next dive. 7. Violation modes the datamax sport ...

  • Page 20

    16 dive log mode displays dive #, maximum depth (noted by mode labels “max ft”), and total bottom time (underneath the mode label “bot- tom”). It will also show the tissue loading bar graph reading that was recorded at the end of the dive. It also shows the maximum ascent rate value reached in the v...

  • Page 21

    17 ing four hours after the last dive has ended to assist you with deciding when enough surface time has elapsed to fly. It is part of the pre dive planning sequence and shows the letter “f” with a countdown timer below that starts at 20 hours (fig. 14). Twelve hours after the last dive, the dive co...

  • Page 22

    18 dive. Above water, you will view the pre dive planning sequence, surface, and time to fly modes. Become familiar with all ten modes so that you understand exactly what the datamax sport is telling you. Informational displays each datamax sport numeric or graphic display represents a unique piece ...

  • Page 23

    19 graphic diver interface ™ two different bar graphs are located around the perimeter of the datamax sport lcd (fig. 17). They are color coded green, yellow, and red to denote normal, caution and danger zones, respectively. The graphic diver interface allows you to make quick status checks underwat...

  • Page 24

    20 variable ascent rate indicator ™ - vari the variable ascent rate indicator (vari) occupies the bottom portion of the datamax sport display (fig. 17b). The purpose of the vari is to assist the diver in preventing too rapid an ascent by providing a visual indication of ascent speed. The bar graph i...

  • Page 25

    21 maximum allowable nitrogen levels developed by merrill spencer. Repetitive diving control is based upon experiments designed and conducted by dr. Ray rogers and dr. Michael powell in 1987. Diving science and technology ® (dsat), a corporate affiliate of padi ® , commissioned these experiments and...

  • Page 26

    22 flying after diving in 1990 the undersea and hyperbaric medical society published a set of guidelines aimed at minimizing the possibility of decompression sickness due to flying too soon after diving. The uhms suggests 1 divers using standard air tanks and exhibiting no symptoms of decompression ...

  • Page 27

    23 there can be a guideline that represents the best estimate for a conservative . . . Surface interval for the vast majority of divers. There will always be an occasional diver whose physiological makeup or special diving circumstances will result in the bends.” the time to fly display (fig. 19) pr...

  • Page 28

    24 ft ft surface surface datamax sport ® ® ° ° f f surface mode no-decompression dive decompression dive delayed violation tlbg & vari fig. 20 –the datamax sport at–a–glance ft ft ndc ndc plan plan datamax sport ® ® ft ft ndc ndc datamax sport ® ® max max ft ft bottom bottom datamax sport ® ® ° ° f ...

  • Page 29

    Handling the extremes.

  • Page 30

    26 handling the extremes datamax sport maximum depth the datamax sport will display a maximum depth of 249 feet. If you exceed that depth, the depth, max depth, and dive log readouts will display “ ” signifying that you descended out-of-range (fig. 21a). For that dive, you will not see a numeric dep...

  • Page 31

    27 practical to stay within the 11 minutes of no-decompression time allowed at 130 feet. If you exceed 160 feet, watch the sport closely because you will enter decompression rapidly. The tissue loading bar graph will alert you when entering decompression by entering the red zone (fig. 22) and chang-...

  • Page 32

    28 violation modes if you exceed certain limits, the datamax sport will not be able to tell you how to get back to the surface. These situations will make the sport enter violation mode and must be avoided at all costs. They push decompression theory to the limits and can result in loss of some data...

  • Page 33

    29 ft ft dec datamax sport ® ® conditional violation – ascending shallower than decompression ceiling the datamax sport will enter a conditional violation mode if you ascend shallower than the decompression ceiling indicated by the tissue loading bar graph (fig. 23). A momentary rise above the ceili...

  • Page 34

    30 begins, the tissue loading bar graph will recede towards the caution zone. Upon entry into the caution zone the sport will revert to ndc mode. Permanent violation modes if you exceed the boundaries of a conditional violation mode, or exceed a 40 ft. Stop requirement, one of two permanent violatio...

  • Page 35

    31 time display. To get back to the surface, the diver must ascend to just deeper than 40 feet staying as close to 40 feet as possible without causing the dec time display to flash. The dec digits may flash at depths slightly deeper than 40 feet in some situations. If this happens, descend to the sh...

  • Page 36

    32 window, it is still possible to get back to the surface with the assistance of the datamax sport. As previously described, you would then need to follow the ceiling toward the surface as the tissue loading bar graph recedes toward the caution zone. Upon reaching zero decompression time remaining,...

  • Page 37

    33 ft ft datamax sport ® ® bottom bottom violation mode. The sport offers no indication of how much time spent underwater would result in the need for greater than a 40 foot decompression ceiling. Watch the display closely to keep from exceeding the tissue loading bar graph’s capabilities and losing...

  • Page 38

    34 above water, gauge mode is indicated by the lack of a pre dive planning sequence or time to fly display. Twelve hours after surfacing, a countdown timer with “triple dash” display will inform you of the number of hours remaining before normal operation can resume (fig. 27). Caution zone – c.Z. Wh...

  • Page 39

    35 what to do if your dive computer quits working because a dive computer is an electronic, battery powered instrument, the possibility that it may quit working unexpectedly is very real - even with new, highest quality batteries. While no-decompression diving, if you find that any major piece of eq...

  • Page 40: 32° F

    36 operating temperature the datamax sport will operate in almost any temperature diving environment in the world (fig. 28) - between 32 ° to 140 ° degrees fahrenheit (0 ° to 60 ° celsius). You may notice the liquid crystal display becoming sluggish at extremely low temperatures. This is normal and ...

  • Page 41

    37 that you carry a chemical lightstick (fig. 29) on all low light dives or a back- up dive light, in case of primary light failure. Sharing the datamax sport the datamax sport provides information based upon your personal dive profile and therefore must not be “shared” between divers. You should ne...

  • Page 42

    38 (this page intentionally left blank).

  • Page 43

    Care and maintenance.

  • Page 44

    40 care and maintenance the datamax sport is a sensitive electronic instrument. Although it has been designed to survive the rigors of diving, it still must be handled carefully to protect from shock, excessive heat, chemical attack, and tampering. The datamax sport is protected by an outer rubber b...

  • Page 45

    41 between your computer and first stage allowing easy removal when not in use (if you have a console version). This allows you to keep the sport nearby when recording dives in your log book or planning the next dive. During the dive keep the datamax sport protected from abuse underwater by using th...

  • Page 46

    42 annual dealer inspections & factory service like all oceanic instrumentation, the datamax sport should be inspected annually by an authorized oceanic dealer. They will perform a depth accuracy test, function check, and routine inspection for damage or wear. To keep the two-year limited warranty i...

  • Page 47

    43 warning - never pressure test the datamax sport in an air envi- ronment. Doing so may damage the depth sensor; possibly result- ing in erroneous depth or time readings. The datamax sport must be placed completely underwater when being pressure tested to protect the depth sensor. If your local fac...

  • Page 48

    44 ft ft surface surface datamax sport ® ® batt batt low low 6. If you have any questions regarding datamax sport service, call oceanic customer service at (510) 562-0500 or email service@oceanicusa.Com. Low batt display the low batt display on the datamax sport lcd alerts you to the impending need ...

  • Page 49

    45 datamax sport battery replacement instructions removing the module from its boot 1. If the module is in a wrist boot, it will be necessary to peel the lips of the boot downward off the gauge while applying pressure from underneath, working it out slowly. If in a console, bend the rubber console b...

  • Page 50

    46 battery removal & installation warning - removal of the datamax sport's batteries will clear all stored memory of tissue loading. If you have been diving immedi- ately prior to replacing the batteries, you must wait 24 hours before diving again. 1. Apply a nickel or quarter (not a screwdriver) to...

  • Page 51

    47 battery compartment and discard, regardless of age or amount of use. Closely examine the metal contacts inside the battery compartment, checking closely for any signs of stress (bending) or breakage. Also, look for any signs of corrosion which may indicate the entrance of moisture into the unit. ...

  • Page 52

    48 flush with the outer surface of the caseback. Returning the module to its boot 1. Orient the module over the hole in the boot, and dip the bottom edge into the hole while pressing the top edge with the palm of your hand. Stop pressing when the bottom ridge has just entered the rubber boot 2. Corr...

  • Page 53

    Reference.

  • Page 54

    50 no. Of segments tissue half–time display as seen by diver max max max max ft ft m m ndc ndc datamax sport ® ® max max ft ft m m ndc ndc datamax sport ® ® max max ft ft m m ndc ndc datamax sport ® ® max max ft ft m m ndc ndc datamax sport ® ® max max ft ft m m ndc ndc datamax sport ® ® max max ft ...

  • Page 55

    51 dives deeper than 90 feet, or decompression dives. Datamax sport decom- pression predictions are therefore based on u.S. Navy theory due to the present unavailability of statistical data. Therefore, pay special attention to the following warnings. Warning – oceanic advocates responsible diving pr...

  • Page 56

    52 fig. 36 – no-decompression limits – datamax sport vs. U.S. Navy tables depth datamax u.S. Sport-e navy feet mins. Mins. 30 260 – – 35 – – 310 40 136 200 50 78 100 60 55 60 70 40 50 80 31 40 90 25 30 100 20 25 110 17 20 120 13 15 130 11 10 140 9 10 150 8 5 160 7 5 170 ––* 5 180 ––* 5 190 ––* 5 * t...

  • Page 57: No-Decompression

    100 ft. 120 ft. 140 ft. 80 ft. 60 ft. 40 ft. 20 ft. 0 ft. 160 ft. 10 minutes 20 30 40 50 0 180 ft. 200 ft. 100 ft. 120 ft. 140 ft. 80 ft. 60 ft. 40 ft. 20 ft. 0 ft. 160 ft. 10 minutes 20 30 40 50 0 180 ft. 200 ft. Fig. 38 – decompression violation limits no-decompression fig. 37 – maximum no-decompr...

  • Page 58

    54 decompression violation limits as described on pages 28 – 33, the datamax sport has two permanent violation modes that will result in the loss of some computer functions if entered. These are termed, delayed and immediate violation modes. Figure 38 shows a chart which details where those limits o...

  • Page 59

    Notes.

  • Page 60

    56 specifications no-decompression model basis • modified haldanean algorithm • 12 tissue compartments data base • diving science and technology (dsat) – rogers/powell performance • tissue compartment half-times (in mins.) spencer’s “m”-values 5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480 • r...

  • Page 61

    57 special displays occurrence • diagnostic display activation • out of range 250+ feet • gauge mode countdown timer 12 – 24 hours after violation • external calibration access (ea) if activation button is held for six seconds during last dive in dive log. Operational performance function accuracy •...

  • Page 62

    58 do you really know how to use the datamax sport? Test your knowledge of how to operate the datamax sport by checking true ( t) or false ( n n f) in pencil. An- swers are found on the bottom of the next page and in the owner’s guide on the pages listed in parentheses. 1. __ t __ f your two-year wa...

  • Page 63

    59 19. __ t __ f gauge mode occurs after a permanent violation mode has been entered. (pg. 33) 20. __ t __ f the dive log display retains the last day’s dives indefinitely until the next dive begins. (pg. 15) 21. __ t __ f you won’t enter violation mode if you require a decom ceiling greater than 40...

  • Page 64: Divelog Instructions

    Dive no. Dive site location date visibility purpose buddy buddy cert. # today cumulative 2 84 1994 ® © ® divelog instructions 100 ft. 120 ft. 140 ft. 80 ft. 60 ft. 40 ft. 20 ft. 0 ft. 160 ft. 10 minutes 20 30 40 50 0 180 ft. 200 ft. Dive site name city, state or country today’s date vis in feet or m...

  • Page 65: Divelog

    ® divelog max ft bottom log datamax sport ® ® today cumulative 1994 ® © 100 ft. 120 ft. 140 ft. 80 ft. 60 ft. 40 ft. 20 ft. 0 ft. 160 ft. 10 minutes 20 30 40 50 0 180 ft. 200 ft. Dive no. Dive site location date visibility purpose buddy buddy cert. # profile: pdps plan actual.

  • Page 66

    62 glossary the following are diving terms that you should become familiar with. Many definitions given below apply specifically to the datamax sport. Algorithm - a step-by-step mathematical formula designed to accomplish a particular result (i.E. Dive time remaining in the datamax sport) altitude d...

  • Page 67

    63 dcs - abbreviation for decompression sickness, i.E., “the bends” dec - abbreviation for decompression decompression ceiling - the shallowest depth a diver may reach upon ascent without risking decompression sickness (also see tlbg) decompression stop - the depth(s) at which a diver must pause dur...

  • Page 68

    64 modular dive computer - a dive computer that is not connected to the diver’s air supply multiplexing display - a display on an instrument that alternates to show different information relating to separate events multi-level dive - a type of dive profile where the diver spends various times at dif...

  • Page 69

    65 square wave dive - a type of dive profile where the entire dive is spent at one depth between descent and ascent tissue - see compartment tissue compartment - see compartment tissue loading bar graph ™ - a graphic display of simulated nitrogen absorption on oceanic dive computers tlbg - abbreviat...

  • Page 70

    66 index a accuracy 57 activation 2, 57 accidental underwater 10 how to 10 alternate dive mode 3, 12 altitude algorithm 56 diving 7, 21 range 21, 57 b battery automatic shut-off 10 life expectancy 57 low batt display 44 replacement 45-48 boot 40 c care & maintenance 40 caution zone 19, 34 cautions i...

  • Page 71

    67 g gauge mode 15, 33 glossary 62 graphic diver interface 3, 56 tissue loading bar graph 19 variable ascent rate indica- tor 20, 56 i immediate violation mode 32 informational displays 18 installation 2 introduction 2 l low batt display 44 m maintenance after dive 41 annual inspection 42 before div...

  • Page 72

    68 t tables, u.S. Navy 52 temperature 7 test 58 testing depth accuracy 42 time to fly 7, 16 tissue compartment 20 tissue half-times 50, 56 tissue loading bar graph 4, 13, 19, 27, 34 training ii turning on display 10 u u.S. Navy tables 52 underwater activation 10 v variable ascent rate indica- tor 4,...

  • Page 73

    69 datamax sport annual inspection record serial number _______________ date of purchase _____________ purchased from ______________ to be filled in below by authorized dealer: date dealer name & number technician name r e s p o n sible d iv e r the code of the responsible diver: as a responsible di...

  • Page 74

    70 datamax sport annual inspection record to be filled in below by authorized dealer: date dealer name & number technician name decompression rules are not meant to be bent responsible.

  • Page 75: Responsible Computer Diving

    Responsible computer diving • always make your deepest dive first • always make the deepest part of every dive, first • check your computer often • do a safety stop on every dive • adequate surface interval between each dive • adequate surface interval between each day of diving (12 hours or until y...

  • Page 76

    © 2002 design 1999 doc. No. 12-1868,r1 (4/99) oceanic usa 2002 davis street san leandro, ca. 94577 usa phone: 510/562-0500 fax: 510/569-5404 web: http://www.Oceanicusa.Com.