Oceanic PROPLUS X Operating Manual

Summary of PROPLUS X

  • Page 1

    1 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) proplus x dive computer operating manual.

  • Page 2: Contents

    2 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) contents notices 3 getting started 5 basics 6 power 6 charging the battery 6 activation 6 quick disconnect hose 7 buttons 9 home menu 10 home menu 11 my info 11 proplus x info 11 setup menu 12 1: brightness set menu 12 2: bl...

  • Page 3

    3 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) limited two-year warranty for details, refer to the product warranty registration card provided. Register on line at www.Oceanicworldwide.Com copyright notice this operating manual is copyrighted, all rights are reserved. It...

  • Page 4: Welcome

    4 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) welcome to oceanic and thank you for choosing the proplus x.

  • Page 5: Getting Started

    5 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) getting started.

  • Page 6

    6 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) basics the proplus x is an easy to use dive computer utilizing a four button interface. Divers may choose between either dive or gauge mode. Though the proplus x is easy to use, you will get the most out of your new proplus ...

  • Page 7

    7 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) quick disconnect hose the quick disconnect allows for convenient removal and storage of your proplus x console. Removal • turn the locking collar counterclockwise to loosen. • then push the hose fitting towards the proplus x...

  • Page 8: Surf

    8 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) symbol meaning 74° f pm 70% battery level (0 - 100%) bluetooth is on surf surface time ft or m depth (feet or meters) dive dive number psi or bar gas pressure gtr gas time remaining ndc no decompression time otr oxygen time ...

  • Page 9: 23 59

    9 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) gas 1 - air fo2 po2 - surf : 23 59 norm 74° f 12:36 pm 70% 0 tl % 3000 psi s1a (v) to menu - (>) to compass 0 dive -- gtr buttons the proplus x utilizes 4 control buttons up, down, left, and right. They allow you to select m...

  • Page 10: Home Menu

    10 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) home menu.

  • Page 11

    11 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) home menu this is a base menu that provides access to general items common to all the operating dive modes. When the proplus x is activated manually, this is the first screen you will see after the welcome screen. When read...

  • Page 12

    12 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) setup menu this menu allows you to adjust the brightness, bluetooth®, set date-time, calibrate compass, and set declination features. (>) to set brightness bluetooth set date, time cal compass set declination home setup men...

  • Page 13

    13 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) b: s et a uto d im while underwater the proplus x screen dims after a set time interval from the last button press. This is done to reduce distractions during the dive and to conserve power. The proplus x allows you to cust...

  • Page 14

    14 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 3: date, time set menu within this menu you can set the formats, date, and time of day. ( date format date time time format date, time set menu m.D select to access controls scroll up scroll down back to setup menu to set a...

  • Page 15

    15 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) c: s et t ime f ormat choose your preferred hour format. (>) to set date format date time time format date, time set menu 12 hr (am, pm) select to access controls toggle setting toggle setting back to set menu to save setti...

  • Page 16

    16 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 5: set declination magnetic declination or variation measures the angle between the earth's magnetic north and true north. The declination value for any region can be found on current geographical charts. By correcting for ...

  • Page 17

    17 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 2/14/13 log data 3 #2 51 date # log 10/28/12 #2 50 10/28/12 #1 49 9/2/12 #1 48 9/1/12 #4 47 9/1/12 #3 49 9/1/12 #2 48 8/1/12 #1 47 fo2 set 32 % max po2 0.86 ata o2 sat (end) 42 % z+ ^ - up list v - down list > - to data 2 (...

  • Page 18: Dive Features

    18 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) dive features.

  • Page 19: 125

    19 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) dtr (dive time remaining) the proplus x constantly monitors no decompression status and o2 accumulation, and will display whichever time is the least amount available as dtr on the no decompression dive main screen. The tim...

  • Page 20: 1261

    20 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) ascent rate bar graph the ar (ascent rate) bar graph provides a visual representation of ascent speed (i.E., an ascent speedometer). When the ascent is faster than the recommended 30 fpm (9 mpm), the bar graph will flash re...

  • Page 21: 10 23

    21 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) safety stop upon ascent to within 5 ft (1.5 m) deeper than the ss (safety stop) depth set for 1 second on a no decompression dive in which depth exceeded 30 ft (9 m) for 1 second, a beep will sound and a safety stop at the ...

  • Page 22

    22 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) audible alarm while operating in norm or gauge mode, the audible alarm will emit 1 beep per second for 10 seconds when alarms strike. During that time, the audible alarm can be acknowledged and silenced by pressing the up b...

  • Page 23: Norm Surface Mode

    23 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) norm surface mode.

  • Page 24: 23 59

    24 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) on the surface before a dive the norm surface main screen will display the surf (surface time), dive number, gas pressure, any residual nitrogen loading, and the selected fo 2 of the breathing gas. The surface time displaye...

  • Page 25

    25 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) last dive data this screen displays essential data from the last dive. If there has been no dive within the current activation cycle, the the max depth and elapsed dive time will be displayed as zero. Norm last dive data ma...

  • Page 26

    26 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) set gas within this submenu you can change the available gas mixes from off, air, or to any nitrox mix between 21 - 100 fo2 (% o2). Nitrox mixes are displayed with their corresponding mod (maximum operating depth) and the c...

  • Page 27: 130

    27 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 1: audible the audible alarm allows you to set audible alarms on or off. Audible depth edt tlbg turn press dtr low press set audible alarm on setting ^ - toggle v - toggle > - save ( controls toggle setting toggle setting t...

  • Page 28: 1139

    28 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 4: tlbg (tissue loading bar graph) this feature allows you to set an alarm to go off at a predetermined percentage of tissue loading bar graph being filled. Audible depth edt tlbg dtr turn press low press set tlbg alarm 80 ...

  • Page 29: 400

    29 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 7: low press the low pressure alarm allows you to set an alarm for when you reach a designated end pressure. You may choose from from 300 to 1500 psi (20 to 105 bar) in increments of 100 psi (5 bar). Note: the low pressure ...

  • Page 30

    30 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 2: units the units feature allows you to select whether imperial (ft, psi) or metric (m, bar) units of measure will be displayed. Units water type deep stop safety stop algorithm conservative sample rate set units of measur...

  • Page 31

    31 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 5: algorithm this feature allows the choice of using the z+ or dsat algorithms, for nitrogen and oxygen calculations. See page 20 for further dual algorithm details. Note: changing the algorithm is blocked during 24 hours a...

  • Page 32

    32 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 7: sample rate the sample rate controls how frequently the proplus x stores a data snapshot for pc download during a dive. Setting options are 2, 15, 30, or 60 second intervals. Shorter intervals will provide a more precise...

  • Page 33

    33 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) norm dive preview gas 1 fo2 po2 al gas 2 fo2 po2 al depth al edt al dtr al water type safety stop = air = 32%, 1.40 = 120 ft = 50 min = 5 min = sea = 15 ft , 3 min ( controls to main menu view preview upon accessing this sc...

  • Page 34: Norm Dive Mode

    34 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) norm dive mode.

  • Page 35: 1261

    35 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) initiating a dive with the proplus x in dive mode, a dive will commence upon descending to 5 ft (1.5 m) for at least 5 seconds. Below is a diagram to help you navigate dive mode functions. Controls to acknowledge alarm to m...

  • Page 36

    36 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) set brightness gas switch more data ds preview dive menu norm 80 % (>) to set adjust select to by % controls scroll up scroll down to dive main to set dive menu set brightness, more data, gas switches, and deep stop preview...

  • Page 37

    37 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) 3: gas switch warning: historically, many accidents and near misses have occurred by switching to the wrong gas at the wrong depth. Do not attempt gas switch decompression dives without proper education and training to do s...

  • Page 38: 1453

    38 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) ar % 11 ds gas 1 - air fo2 po2 - 16 ft norm 74° f 12:36 pm 70% 54 tl % 1453 psi (v) to menu - (>) to compass 32 gtr earmark applied earmark by holding the left button for more than 2 seconds during a dive you can manually r...

  • Page 39: 138

    39 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) complications the preceding information has described standard dive operations. Your new proplus x is also designed to help you to the surface in less than ideal situations. The following is a description of these situation...

  • Page 40: 1198

    40 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) delayed violation 3 if you descend deeper than the maximum functional depth*, the audible alarm will sound. Also, the up arrows, and too deep message will flash. Only dashes will display for current depth and ndc (no decomp...

  • Page 41: 136

    41 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) ar % 0 - gas 1 air fo2 po2 - - - tl % (v) to menu - (>) to compass go up violation 136 ft 1067 psi 18 gtr violation gauge mode (vgm) during a dive during dive mode dives, operation will enter vgm when decompression requires...

  • Page 42: 128

    42 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) alarm if po 2 continues to increase and reaches the alarm set point, the audible alarm sounds again. The po 2 value, go up message, and up arrows will flash during the audible alarm. After the audible alarm is silenced, the...

  • Page 43: 1024

    43 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) warning during decompression when o2 sat reaches the warning level, the audible alarm sounds and the o2 sat value will flash in the middle of the screen. When the audible alarm is silenced, the o2 sat value will alternate w...

  • Page 44: Gauge Mode

    44 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) gauge mode.

  • Page 45: 0 26

    45 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) on the surface before a dive gauge surface main is nearly identical to dive mode. Unlike dive mode, there will be no tissue loading bar graph or gas mix values displayed. Controls to main menu to home menu to compass surf 0...

  • Page 46

    46 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) note: all other gauge mode dive functions are similar to norm mode. See the norm dive mode chapter for further details..

  • Page 47: Compass Mode

    47 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) compass mode.

  • Page 48: North

    48 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) ar % 11 north 12:36 74° f : pm 70% 22 sec ( 54 tl % surf 1 56 147° compass display icons 1 compass mode 2 depth or surface time 3 heading correction arrow 4 heading marker 5 time out countdown 6 heading degrees 7 ascent rat...

  • Page 49

    49 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) overview the proplus x is equipped with an advanced 3d digital compass. Compass mode can be activated while in dive or gauge operation modes by pressing the right button. • the proplus x reverts back to the previous operati...

  • Page 50: 1:56

    50 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) reference 74° f ref 147° 12:36 pm : 1:56 70% 54 tl % ( surf 147° controls to north mode to norm/gauge main to apply earmark to set heading reference main reference/reverse reference the reference modes allow you to select c...

  • Page 51: Reference

    51 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) reference.

  • Page 52

    52 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) uploading/downloading data as previously described (page 13), the proplus x can be paired using the bluetooth® feature. This requires a pc, mac, or mobile device running diverlog software and equipped with bluetooth® functi...

  • Page 53

    53 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) altitude sensing and adjustment altitude (i.E., ambient pressure) is measured upon activation and every 15 minutes until a dive is made. • measurements are only taken when the unit is dry. • two readings are taken, the seco...

  • Page 54: Technical Data

    54 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) technical data.

  • Page 55

    55 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) altitude levels display : range: • sea = level 1 (sea level) 0 to 3,000 feet (0 to 915 meters) • l2 = level 2 3,001 to 5,000 feet (916 to 1,525 meters) • l3 = level 3 5,001 to 7,000 feet (1,526 to 2,135 meters) • l4 = level...

  • Page 56

    56 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) z+ based ndls (hr:min) (imperial) altitude 0 3001 4001 5001 6001 7001 8001 9001 10001 11001 12001 13001 (feet) to to to to to to to to to to to to 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 depth (ft) ...

  • Page 57

    57 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) can be used as • dive computer (air or nitrox) • digital depth gauge/timer dive computer performance • buhlmann zhl-16c based pz+, or dsat based, algorithm. • no decompression limits closely follow padi rdp. • decompression...

  • Page 58

    58 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) numeric displays: range: resolution: • temperature 0 to 140 f (-18 to 60 c) 1 degree • altitude level sea, el2 to el7 1 level • depth, max depth 0 to 330 ft (100 m) 1 ft (0.1 m ) • time to fly 23:50 to 0:00 hr:min* 1 minute...

  • Page 59

    59 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) abbreviations/terms al = alarm ar = ascent rate ata = atmospheres absolute aud = audible bar = metric unit of pressure batt (bat) = battery cal = calibrate (compass cdt (cd) = countdown timer chg = change conserv = conserva...

  • Page 60

    60 proplus x operating manual © pelagic, 2016 doc. No. 12-5655-r01 (8/19/16) inspection / service record serial number: ___________________________________________________________________________________________________ firmware rev: __________________________________________________________________...

  • Page 61: Proplus X