Oertzen Compact 120 K Operation Manual

Manual is about: high pressure cleaner

Summary of Compact 120 K

  • Page 1

    Operation manual compact 120 k 11/06 von oertzen gmbh • ferdinand-harten-str. 10 • 22949 ammersbek • tel. +49 40 604110 • fax +49 40 6041149 www.Oertzen-gmbh.De • info@oertzen-gmbh.De.

  • Page 2

    2 table of content 1. Introduction page 3 2. Safety instructions page 4 - 5 3. Design/configuration/illustration page 6 - 7 4. Start-up/shut-down page 8 - 11 5. Maintenance and care page 12 - 15 6. Electric wiring diagram page 16 7. Technical data page 16 8. Trouble shooting page 17 9. Declaration o...

  • Page 3

    3 1. Introduction with your oertzen high pressure cleaner you have purchased one of the most durable and reliable machines available on the market. Its balanced ratio of water flow (temperature) and working pressure perfectly meets all cleaning requirements. The oertzen high pressure cleaners confor...

  • Page 4

    4 2. Safety instructions the following instructions to be followed before, during and after work: this instruction manual to be read completely before initial start-up. If strictly followed, no dangers should occur. This machine must only be run by qualified adult persons who are fully familiar with...

  • Page 5

    5 before opening the machine in case of malfunction or emergency, switch off by means of the on/off switch and disconnect it from electric power source. Electric power can cause severe injuries. All symptoms of faulty electric components to be taken seriously and possible causes for accidents to be ...

  • Page 6

    6 3. Design/configuration/illustration the hot water cleaners of this series mainly comprise a low speed high pressure inline plunger pump incl. Of safety shut-down system and a high performance oil heating unit with vertical double-shell stainless steel heat exchanger. The high pressure inline plun...

  • Page 7

    7.

  • Page 8

    8 4. Start-up/shut-down before start-up read operation manual and follow instructions. Upon start-up of the high pressure cleaner indoors, proper ventilation and exhaust evacuation to be guaranteed. Relevant safety regulations to be followed. In order to guarantee proper condition of the machine and...

  • Page 9

    9 electric connection connect the unit to a 230 v power source which is protected by 16 a (slow). Extension cables to have a diameter according to vde regulations. Extension cables on reels to be reeled off completely, in order to avoid overheating of the cable reel. Plugs, couplings to be water-pro...

  • Page 10

    10 detergent dosing only detergents approved by oertzen to be used. Use of hazardous detergents or detergents not approved by oertzen ceases warranty and product liability. Depending of kind and composition of detergent, it can be used in cold and hot water mode. Observe manufacturer's instructions....

  • Page 11

    11 after completion of work switch off burner/thermostat switch (23) – pos. "0". Run machine in cold water mode for a couple of minutes. Close spray pistol. The unit to be switched off by means of the on/off switch (2) – pos. "0". De-pressurise the spray pistol by shortly opening and closing. Discon...

  • Page 12

    12 5. Maintenance and care every machine is only as reliable as its maintenance personnel. It is most important that the operator carries out the following maintenance work in shorter time periods than the normal maintenance intervals: high pressure pump first oil change to be carried out after 50 o...

  • Page 13

    13 fuel tank immediately remove dirt deposits in the fuel tank (19), if any. Boiler cleaning if soot is detected in the unit, stop operation at once (danger of explosion). Clean heating coil and pre-heater as required, at least as soon as soot deposits are being found on the heating coil or soot is ...

  • Page 14

    14 maintenance intervals all maintenance intervals stated apply under the provision that the machine will be operated according to design limits and that the machine will be fed with clean water/consumables. Otherwise maintenance intervals to be shortened. Only original oertzen spare parts to be use...

  • Page 15

    15 frost protection frost-protection of the machine is of vital interest, because frost can cause severe damage on the entire system. The best frost protection is to store the machine/accessories in a permanently frost-protected area. If there is a risk of temperatures below freezing point during st...

  • Page 16

    16 6. Electric wiring diagram 7. Technical data technical data compact 120 k flow rate/adjustable 540 l/h unloading pressure * 140 bar max. Working pressure/adjustable 120 bar water temperature/adjustable 30 – 90 °c voltage 1 ~ 230 v total power connected 2,4 kw power consumption 10,5 a heating capa...

  • Page 17

    17 8. Trouble shooting electricity can cause severe injuries. Electrical components thoroughly and frequently to be checked for damages and malfunctions, in order to avoid any cause for accidents. Disconnect the unit from the electrical network during all repair/maintenance work (zh 1/95). Trouble s...

  • Page 18

    18.