Oertzen M 320 Operation Manual

Summary of M 320

  • Page 1

    To be read carefully before start-up! Operation manual m 320 von oertzen gmbh • ferdinand-harten-str. 10 • 22949 ammersbek • tel. +49 40 604110 • fax +49 40 6041149 www.Oertzen-gmbh.De • info@oertzen-gmbh.De 03/08.

  • Page 2: Table Of Content

    2 table of content 1. Introduction page 3 2. Safety instructions pages 4 – 5 3. Configuration/illustration pages 6 – 7 4. Start-up/operation/shut-down pages 8 – 11 5. Maintenance and care pages 12 – 14 6. Technical data page 15 7. Trouble-shooting pages 16 8. Declaration of conformity page 17 m3 20-...

  • Page 3

    3 1. Introduction with your oertzen high pressure cleaner you have purchased one of the most durable and reliable machines available on the market. Its balanced ratio of water flow (temperature) and working pressure meets all cleaning require- ments. The oertzen high pressure cleaners conform to all...

  • Page 4

    4 2. Safety instructions this instruction manual should thoroughly and completely be studied and considered prior to initial start-up of the unit. When strictly following the instructions, no danger should occur. This machine must only be operated by adult persons who are fully familiar with the ope...

  • Page 5

    5 the unit must not be placed or operated in areas jeopardised by fire or explosions. During work at filling stations the “technical rules for flammable liquids (tfbf) to be considered. Consumables to be handled thoroughly and strictly in accordance with all relevant safety regulations and rules of ...

  • Page 6

    6 3. Configuration/illustration the machines of the mobile series consist of a low speed, oil-greased high pressure inline plunger pump, driven by a low-emission 4-stroke motor in v- design. An oil-greased reduction gear flanged between pump and motor reduces the high pressure pump speed. In order t...

  • Page 7

    7.

  • Page 8

    8 4. Start-up / shut-down before start-up: before start-up of a machine of the oertzen mobile series, the following instructions to be followed: operating manual of machine and motor to be read thoroughly and considered. Check correct oil levels of high pressure pump (dip stick (8)), reduction gear ...

  • Page 9

    9 connections water connection the water inlet to be connected to the water distribution network by means of an internally clean, min. ” water hose. Water hose to be flushed before connection. When connecting the unit to the potable water supply, din 1988 to be observed (for short-term connections a...

  • Page 10

    10 start with electric starter choke of the combustion engine to be pulled, respectively lever to be turned. Speed control lever (5) in position “full load”. Starter key to be put into position “start” and starter push button to be pressed. As soon as it has started, open choke until the motor is ru...

  • Page 11

    11 after work reduce motor load by decreasing working pressure (open valve at double lance, respectively by turning the adjusting wheel of the unloader valve counter-clockwise), in order to cool down the motor after work. Close and lock spray pistol. Motor stop: tumbler to be in position "0". Thorou...

  • Page 12

    12 5. Maintenance and care every machine is only as reliable as maintenance is carried out. In order to guarantee reliability and trouble free operation of the machine, it is of vital interest to follow the instructions below: ignoring the required maintenance intervals voids all warranty. Combustio...

  • Page 13

    13 water filter the cartridge filter is arranged in the water inlet and must be inspected prior to start up. Change filter cartridge, if needed. Supply of polluted water or dirty strainer will cause severe damage on the pump and unloader valve. Frost protection proper frost protection of the machine...

  • Page 14

    14 6. Technical data technical data mobil 320 water consumption/adjustable 500 – 1440 l/h max. Operating pressure 325 bar working pressure/adjustable 310 bar power 22 ps/17 kw fuel consumption at full load 7,7 l/h tank volume 20 l oil shortage cut-out standard starting device battery start dimension...

  • Page 15

    15 7. Trouble shooting electrical energy can cause severe injuries. Defective electrical components to be immediately replaced, possible causes for accidents to be eliminated without delay any repair work must only be carried out by qualified personnel. Only original oertzen equipment to be installe...

  • Page 16

    16.