Oertzen M 400 Operation manual

Manual is about: Cold Water High Pressure Cleaner with Combustion Engine

Summary of M 400

  • Page 1

    Operation manual cold water high pressure cleaner with combustion engine m 400 m 500 to be read carefully before start-up! Von oertzen gmbh • ferdinand-harten-str. 10 • 22949 ammersbek • tel. +49 40 604110 • fax +49 40 6041149 www.Oertzen-gmbh.De • info@oertzen-gmbh.De.

  • Page 2: Table Of Content

    2 table of content 1. Introduction page 3 2. Safety instructions pages 4 – 5 3. Configuration/illustration pages 6 – 7 4. Start-up/operation/shut-down pages 8 – 12 5. Maintenance and care pages 13 – 14 6. Technical data page 15 7. Trouble-shooting pages 16 8. Declaration of conformity page 17 m4 00-...

  • Page 3

    3 1. Introduction by buying the oertzen equipment you have purchased one of the most durable and reliable high pressure cleaners available on the market. Its balanced ratio of water flow (temperature) and working pressure perfectly meets all cleaning requirements. The oertzen high pressure cleaners ...

  • Page 4

    4 2. Safety instructions the following instructions to be followed before, during and after work: this instruction manual to be read completely before initial start-up. If strictly followed, no danger should occur. This machine must only be run by qualified adult persons who are fully aware of possi...

  • Page 5

    5 before opening the machine in case of malfunction or emergency, switch off by means of the on/off respectively the emergency stop switch. Electric power can cause serious danger. All symptoms of defective electrical components to be taken seriously and eliminated immediately. Repair works only to ...

  • Page 6

    6 3. Configuration/illustration the machines of the mobile series consist of a low speed, high pressure inline plunger pump, driven by a low-emission 4-stroke engine in v-design. In order to extend the engine lifetime, an oil shortage cut-out is installed, which switches off the engine in case the o...

  • Page 7

    7.

  • Page 8

    8 4. Start-up / shut-down before initial start-up: in case the high pressure pump is secured against oil loss during transport with a plug, this plug to be replaced by the oil dip stick included in our scope of supply. Otherwise heavy damage on the pump set will be the result. Water inlet (6) and hi...

  • Page 9

    9 connections water supply connect water inlet (6) of the machine to water source with a clean hose (diameter see table page 9). Before connecting water supply hose, rinse it thoroughly. In case of connection to the potable water distribution, observe din 1988 (for momentary connections use a backfl...

  • Page 10

    10 operation from production month 07/2005 on the mobile series is equipped with an emergency stop switch (2 a). In case of emergency push emergency stop switch. After elimination of cause emergency stop switch to be released by pulling it out, otherwise machine cannot be re-started. For starting th...

  • Page 11

    11 the engine is additionally equipped with a recoil starter for emergency, in case e.G. The battery trips, which must be used as follows (devices to be handled as described before: start procedure reverse start • turn ignition key clockwise into position "1". • take handle and carefully pull out un...

  • Page 12

    12 every machine is only as reliable as maintenance is carried out. In order to guarantee reliability and trouble free operation of the machine, it is of vital interest to follow the instructions below: ignoring the required maintenance intervals voids all warranty. Combustion engine maintenance ins...

  • Page 13

    13 battery maintenance work to be carried out according to manufacturer’s instructions. Check acid level every week. Refill distilled water whenever needed. Water filter the cartridge filter (5) is arranged in the water inlet (6) and must be inspected prior to start up. Change filter cartridge, if n...

  • Page 14

    14 6. Technical data technical data mobil 400 mobil 500 water consumption/adjustable 500 – 1320 l/h 500 – 1020 l/h unloading pressure 405 bar 520 bar working pressure/adjustable 385 bar 500 bar power rating 22 ps/16,2 kw 22 ps/16,2 kw fuel consumption at full load 7,7 l/h 7,7 l/h tank volume 20 l 20...

  • Page 15

    15 7. Trouble shooting electric power can cause severe injuries. Defective electrical compo- nents to be immediately replaced, possible causes for accidents to be eliminated without delay. Any repair work must only be carried out by qualified personnel. Only original equipment expressively approved ...

  • Page 16

    16.