Oertzen SuperMagnum 220 ELC Operation Manual

Summary of SuperMagnum 220 ELC

  • Page 1

    Operation manual supermagnum 220 elc von oertzen gmbh • ferdinand-harten-str. 10 • 22949 ammersbek • tel. +49 40 604110 • fax +49 40 6041149 www.Oertzen-gmbh.De • info@oertzen-gmbh.De 11/04.

  • Page 2

    2 table of content 1. Introduction page 3 2. Safety instructions page 4 - 5 3. Design, operation, illustrations page 6 - 7 4. Start-up/shut-down page 8 - 12 5. Maintenance and care page 13 - 16 6. Electric wiring diagram page 17 7. Technical data page 17 8. Trouble shooting page 18 9. Declaration of...

  • Page 3

    3 1. Introduction the oertzen high pressure cleaner is one of the most durable and reliable machines on the market. Its balanced ratio of water quantity and operating pressure allows to carry out all cleaning and disinfection work. It conforms to the national and european safety regulations. The ce ...

  • Page 4

    4 2. Safety instructions this operation manual should thoroughly and completely be studied and considered prior to initial start-up of the unit. When strictly following the instructions, no danger should occur. This machine must only be operated by qualified personnel who are fully familiar with the...

  • Page 5

    5 the unit must not be placed or operated in areas jeopardised by fire or explosions. During working at fuel stations the “technical rules for flammable liquids” (tfbf) to be considered. Consumables to be handled thoroughly. Technical safety regulations and environmental rules to be followed. Machin...

  • Page 6

    6 3. Design, operation, illustrations the hot water high pressure cleaner comprises an inline plunger high pressure pump with safety shut-down system a high capacity oil heating system with stainless steel heat exchanger. The high pressure pump is directly flanged to the electric motor. It sucks the...

  • Page 7

    7.

  • Page 8

    8 5. Start-up/shut-down before start-up read operation manual before start-up and follow instructions. Upon start-up of the high pressure cleaner indoors, proper ventilation and exhaust evacuation to be guaranteed. Official safety regulations to be followed. In order to guarantee proper condition of...

  • Page 9

    9 electric connection connect the unit to a 400 v power source which is protected by 3 x 16 a (slow). Extension cables to have a diameter according to vde regulations. Extension cables on reels to be reeled off completely, in order to avoid overheating of the cable reel. Plugs, couplings to be water...

  • Page 10

    10 operation open water source. Unlock and release spray pistol, bleed the unit until blister-free water emerges. Turn on/off/burner switch (2 a) into position i. Adjust thermostat (23 a) to required working temperature. Turn on/off/burner switch (2 a) into position "burner". Carry out cleaning task...

  • Page 11

    11 detergent dosing only detergents approved by oertzen to be used. Use of hazardous detergents or detergents not approved by oertzen ceases warranty and product liability. Depending on the kind of detergent, it can be used in hot or cold water mode. Follow manufacturer's instructions. Turn adjustin...

  • Page 12

    12 after completion of work turn thermostat (23 a) into pos. 0. Run machine in cold water mode for a couple of minutes. Close spray pistol. Switch off machine by means of the on/off/burner switch (2 a). De-pressurise spray pistol by shortly opening and closing. Lock spray pistol. Disconnect machine ...

  • Page 13

    13 5. Maintenance and care every machine is only as reliable as its maintenance personnel. It is most important that the operator carries out the following maintenance work in shorter time periods than the normal maintenance intervals: high pressure pump first oil change to be carried out after 50 o...

  • Page 14

    14 boiler cleaning if soot is detected in the unit, stop operation at once (danger of explosion). Clean heating coil and pre-heater as required, at least as soon as soot deposits are being found on the heating coil or soot is detected in the exhaust fumes. The boiler cleaning and the adjustment of t...

  • Page 15

    15 maintenance intervals all maintenance intervals stated apply under the provision that the machine will be operated according to design limits and that the machine will be fed with clean water/consumables. Otherwise maintenance intervals to be shortened. Only original oertzen spare parts to be use...

  • Page 16

    16 frost protection frost-protection of the machine is of vital interest, as frost can cause severe damage on the entire system. The best frost protection is to store the machine/accessories in a permanently frost-protected area. If there is a risk of temperatures below freezing point during storage...

  • Page 17

    17 6. Electric wiring diagram 7. Technical data technical data supermagnum 220 elc flow rate, adjustable 960 l/h unloading pressure * 230 bar max. Working pressure, adjustable 210 bar water temperature, adjustable 30 – 140 °c normal current (50 hz) 3 ~ 400 v total power connected 6,9 kw power consum...

  • Page 18

    18 8. Trouble shooting electric power can cause severe injuries. Defective electrical compo- nents to be replaced immediately and possible causes for accidents to be eliminated. Repair work to be carried out by qualified personnel. Disconnect the machine from electric power source during repair/main...

  • Page 19