Officezone IDEAL 4850 (18-34'') Operation Manual - Features and Operation
3
4850
4850-90
5250
6550
6550-90
Cutting Length
475 mm
(18-3/4”)
520 mm
(20-1/2”)
650 mm
(25-1/2”)
Cutting Height
80 mm
(3-1/8”)
80 mm
(3-1/8”)
80 mm
(3-1/8”)
Table Depth
460 mm
(18-1/8”)
520 mm
(20-1/2”)
610 mm
(24”)
Narrow Cut
30 mm
(1-3/ 16”)
35 mm
(1-3/8”)
35 mm
(1-3/8”)
With the false clamp mounted on models IDEAL 6550 and IDEAL 6550-90 the cutting height is
reduced to 75 mm (3”), and the narrow cut is 50 mm (2”).
Features and Operation
•
Main Switch (#13)
Turn main switch (#13) to position “|” (on), in order to begin operation. The main switch can also
be used as an EMERGENCY SWITCH, which stops the machine immediately.
•
Safety lock with key (#7)
The key can be removed to prevent unauthorized use. To activate the machine, turn the key 45º to
the right.
•
Re-set button (#14)
Before the knife can be activated on models IDEAL 4850, IDEAL 5250 and IDEAL 6550, the re -
set button has to be pressed to re -establish the “ready to cut” status of the machine. The yellow
pilot light in the vie wing window (#10) illuminates and indicates that the machine is ready to cut.
The models IDEAL 4850-90 and IDEAL 6550-90 do not have a re -set button.
•
Two-hand operation
Only by pressing the push button switches (#5 and #15) simultaneously (within half a second), can
a cut, with automatic clamping operation, be executed. Keep push buttons depressed until the
knife has reached its lowest position. The paper pile will now have been cut through. As soon as
the push buttons have been release, first the knife and then the paper clamp, return automatically
to their home positions.
•
Automatic clamping
When a cut is executed using push buttons (#5 and #15), the paper clamp is also automatically
activated.
Alternatively the clamp can be used independently o f the knife by simultaneously pushing push
button switches (#6 and #15). Then by subsequently pushing buttons (#5 and #15), the cut is
executed separately. Then this is completed, both the knife (#20) and the clamp (#17) return
automatically to their home positions.