Offshore 5801 User manual

Manual is about: BENNETT TRIM TAB ADAPTOR WITH NMEA2000, CAN BUS AND RS485 RTU MODBUS INTERFACES

Summary of 5801

  • Page 1

    V bennett® trim tab adaptor with nmea2000®, can bus and rs485 rtu modbus interfaces part numbers: 5801 user manual revision 1.0.1.

  • Page 3

    1 of 13 1 introduction ...................................................... 2 1.1 firmware revision ........................................... 2 1.2 product features ............................................. 2 2 installation ........................................................ 3 2.1 unpac...

  • Page 4

    Introduction 1 2 of 13 the offshore dynamics 5801 bennett trim tab adaptor is designed to measure the inductive sensors in bennett trim tabs and relay their position over multiple interfaces. The trim tab adaptor is water resistant to ip65. It is designed to be mounted case up in a protected locatio...

  • Page 5

    Installation 2 101.6 121.5 134.7 74.9 41 2 x 7.4 118.7 35.9 33.7 20.7 3 of 8 2.1 unpacking the box you will find the following items in the 5801 shipping box: 1 x 5801 bennett trim tab adaptor 1 x 5801 user manual (this document) 3 x 5801-r trim tab remote 2.2 mounting the unit the unit should be mo...

  • Page 6

    Calibrate stbd modbus port cent gnd p1 p2 gnd c1 c2 gnd s1 s2 gnd a b nmea2000®/ fixed address power input 4 of 13 2.3 connecting the deutsch plug the unit is connected to the sensors and the communications interfaces via the 12 way deutsch plug according to the following connection table: pin numbe...

  • Page 7

    5 of 13 2.4 unit switch settings during initial installation, the unit needs to be opened and switches set to match the units interface connection. If the unit is to be used with a fixed source address style can bus interface, then the fixed address mode switch needs to be set to the on position and...

  • Page 8

    Calibration 3 6 of 13 please note that during the calibration procedure the unit will not attempt to transmit any positional messages. The unit is calibrated as follows: •power up the device. •press the calibrate button so that the white calibration led illuminates. •actuate each sender between it’s...

  • Page 9

    4 7 of 13 maintenance ● clean the unit with a soft cloth. ● do not use chemical cleaners as they may remove paint or markings or may corrode the enclosure or seals. ● ensure that the unit is secure using the mounting holes on the device and cannot be moved relative to the mounting surface. ● check t...

  • Page 10

    5 technical specification 8 of 13 offshore dynamics are constantly improving their products. Specifications are subject to change without notice. Offshore dynamics products are designed to be accurate and reliable, however, they should only be used as aids to navigation and not as a replacement for ...

  • Page 11

    9 of 13 electrical and mechanical environmental description comment operating voltage 9 to 32 volts power consumption 45ma average operating load equivalence number 1 len reverse battery protection yes indefinitely load dump protection yes sae j1113 size 120x135x35 mm weight 230 gram mounting panel ...

  • Page 12

    6 10 of 13 technical support if you require technical support for any offshore dynamics products you can reach us using any of the following:- ● tel: +44(0)1425 610022 ● fax: +44(0)1425 614794 ● email: support@osukl.Com ● web: www.Osukl.Com ● post: offshore dynamics ltd unit 10-11 milton business ce...

  • Page 13

    Warranty 7 11 of 12 offshore dynamics warrants this product to be free from defects in materials and workmanship for one year from the date of original purchase. If within the applicable period any such products shall be proved to offshore dynamics satisfaction to fail to meet the above-limited warr...

  • Page 14

    12 of 13 offshore dynamics product map 8.